Sepp De Raedt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sepp De Raedt has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Maiken Stilling
Aarhus University Hospital
4 shared publications - Bart L. Kaptein
Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands
2 shared publications - Emil Toft Petersen
AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
2 shared publications - Peter Bo Jørgensen
Department of Orthopaedics, Aarhus University Hospital, Aarhus, Denmark
2 shared publications Anna Zejden
Department of Radiology, Aarhus University Hospital, Aarhus, Denmark
1 shared publication- Bjarne Mygind‐Klavsen
Orthopedic Department, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200, Aarhus N, Denmark
1 shared publication
Latest Publications
- Open Access
- 3 June 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (6) , 506-515
One-year follow-up of 20 patients undergoing the Latarjet procedure
Aims: The Latarjet procedure is the treatment of choice for patients who have recurrent anterior shoulder instability with glenoid bone loss. However, the stabilizing effect of the Latarjet procedure in patients is sparsely described. The aim of this study was to evaluate the glenohumeral joint (GHJ) kinematics during an apprehension-relocation test in patients with anterior shoulder instability before and after their Latarjet procedure, and in comparison with their contralateral healthy shoulder.Methods: A total of 20 patients scheduled for the Latarjet procedure were enrolled. The patients were examined preoperatively with bilateral radiostereometric analysis (RSA) and one year after surgery on the operated shoulder with an apprehension-relocation test. Bone models were obtained from CT scans and aligned with the RSA images. The GHJ kinematics was evaluated with two methods: the humeral head centre location relative to the glenoid centre, and the GHJ contact point relative to the glenoid centre.Results: No difference in GHJ kinematics was found between the healthy and the postoperative GHJ. Compared with the preoperative injured shoulder, the postoperative mean (95% CI) humeral head centre was 0.8 mm (0.1 to 1.4) more superior and 0.7 mm (-0.1. to 1.4) more posterior during the apprehension test, and 0.5 mm (0.0 to 1.1) more posterior during the relocation test. The postoperative contact point was posterior to the coracoid bone block and 0.9 mm (-0.2 to 2.0) more posterior than in the preoperative injured shoulder during the apprehension test. The articulating area of the coracoid bone block was decreased by 63.9% (75.5 to 114.6) one year after surgery.Conclusion: The Latarjet procedure restored the humeral head centre location posterior and superior, and the contact point posterior, to the coracoid bone block. This suggests that the stabilizing effect of the GHJ following the Latarjet procedure is primarily due to the conjoined tendon rather than the coracoid bone block itself.Cite this article: Bone Joint Res 2025;14(6):506–515.
- 3 June 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (6) , 506-515
Open AccessOne-year follow-up of 20 patients undergoing the Latarjet procedure
Aims: The Latarjet procedure is the treatment of choice for patients who have recurrent anterior shoulder instability with glenoid bone loss. However, the stabilizing effect of the Latarjet procedure in patients is sparsely described. The aim of this study was to evaluate the glenohumeral joint (GHJ) kinematics during an apprehension-relocation test in patients with anterior shoulder instability before and after their Latarjet procedure, and in comparison with their contralateral healthy shoulder.Methods: A total of 20 patients scheduled for the Latarjet procedure were enrolled. The patients were examined preoperatively with bilateral radiostereometric analysis (RSA) and one year after surgery on the operated shoulder with an apprehension-relocation test. Bone models were obtained from CT scans and aligned with the RSA images. The GHJ kinematics was evaluated with two methods: the humeral head centre location relative to the glenoid centre, and the GHJ contact point relative to the glenoid centre.Results: No difference in GHJ kinematics was found between the healthy and the postoperative GHJ. Compared with the preoperative injured shoulder, the postoperative mean (95% CI) humeral head centre was 0.8 mm (0.1 to 1.4) more superior and 0.7 mm (-0.1. to 1.4) more posterior during the apprehension test, and 0.5 mm (0.0 to 1.1) more posterior during the relocation test. The postoperative contact point was posterior to the coracoid bone block and 0.9 mm (-0.2 to 2.0) more posterior than in the preoperative injured shoulder during the apprehension test. The articulating area of the coracoid bone block was decreased by 63.9% (75.5 to 114.6) one year after surgery.Conclusion: The Latarjet procedure restored the humeral head centre location posterior and superior, and the contact point posterior, to the coracoid bone block. This suggests that the stabilizing effect of the GHJ following the Latarjet procedure is primarily due to the conjoined tendon rather than the coracoid bone block itself.Cite this article: Bone Joint Res 2025;14(6):506–515.
- 6 June 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (12) , 2021-2028
Reliability of computer-assisted periacetabular osteotomy using a minimally invasive approach
Periacetabular osteotomy (PAO) is the treatment of choice for younger patients with developmental hip dysplasia. The procedure aims to normalize the joint configuration, reduce the peak-pressure, and delay the development of osteoarthritis. The procedure is technically demanding and no previous study has validated the use of computer navigation with a minimally invasive transsartorial approach.
- 6 June 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (12) , 2021-2028
Reliability of computer-assisted periacetabular osteotomy using a minimally invasive approach
Periacetabular osteotomy (PAO) is the treatment of choice for younger patients with developmental hip dysplasia. The procedure aims to normalize the joint configuration, reduce the peak-pressure, and delay the development of osteoarthritis. The procedure is technically demanding and no previous study has validated the use of computer navigation with a minimally invasive transsartorial approach.
- Open Access
- 5 June 2017
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 4 (1) , 1-9
Dynamic radiostereometric analysis for evaluation of hip joint pathomechanics
Dynamic RSA (dRSA) enables non-invasive 3D motion-tracking of bones and may be used to evaluate in-vivo hip joint kinematics including hip pathomechanics such as femoroacetabular impingement (FAI) and the biomechanical effects of arthroscopic cheilectomy and -rim trimming (ACH). The study aim was to evaluate the kinematic changes in the hip joint after ACH. Seven non-FAI affected human cadaveric hips were CT-scanned and CT-bone models were created. dRSA recordings of the hip joints were acquired at five frames/s during passive flexion, adduction to stop, and internal rotation to stop (FADIR). ACH was performed and dRSA was repeated. dRSA images were analyzed using model-based RSA. Hip joint kinematics before and after ACH were compared pairwise. The volume of removed bone was quantified and compared to the postoperative range of motion (ROM). Mean hip internal rotation increased from 19.1 to 21.9° (p = 0.04, Δ2.8°, SD 2.7) after ACH surgery. Mean adduction of 3.9° before and 2.7° after ACH surgery was unchanged (p = 0.48, Δ-1.2°; SD 4.3). Mean flexion angles during dRSA tests were 82.4° before and 80.8° after ACH surgery, which were similar (p = 0.18, Δ-1.6°, SD = 2.7). No correlation between volume of removed bone and ROM was observed. A small increase in internal rotation, but not in adduction, was observed after arthroscopic cheilectomy and -rim trimming in cadaver hips. The hip flexion angle of the FADIR test was reproducible. dRSA kinematic analysis is a new and clinically applicable method with good potential to evaluate hip joint kinematics and to test FAI pathomechanics and other surgical corrections of the hip.
- 5 June 2017
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 4 (1) , 1-9
Open AccessDynamic radiostereometric analysis for evaluation of hip joint pathomechanics
Dynamic RSA (dRSA) enables non-invasive 3D motion-tracking of bones and may be used to evaluate in-vivo hip joint kinematics including hip pathomechanics such as femoroacetabular impingement (FAI) and the biomechanical effects of arthroscopic cheilectomy and -rim trimming (ACH). The study aim was to evaluate the kinematic changes in the hip joint after ACH. Seven non-FAI affected human cadaveric hips were CT-scanned and CT-bone models were created. dRSA recordings of the hip joints were acquired at five frames/s during passive flexion, adduction to stop, and internal rotation to stop (FADIR). ACH was performed and dRSA was repeated. dRSA images were analyzed using model-based RSA. Hip joint kinematics before and after ACH were compared pairwise. The volume of removed bone was quantified and compared to the postoperative range of motion (ROM). Mean hip internal rotation increased from 19.1 to 21.9° (p = 0.04, Δ2.8°, SD 2.7) after ACH surgery. Mean adduction of 3.9° before and 2.7° after ACH surgery was unchanged (p = 0.48, Δ-1.2°; SD 4.3). Mean flexion angles during dRSA tests were 82.4° before and 80.8° after ACH surgery, which were similar (p = 0.18, Δ-1.6°, SD = 2.7). No correlation between volume of removed bone and ROM was observed. A small increase in internal rotation, but not in adduction, was observed after arthroscopic cheilectomy and -rim trimming in cadaver hips. The hip flexion angle of the FADIR test was reproducible. dRSA kinematic analysis is a new and clinically applicable method with good potential to evaluate hip joint kinematics and to test FAI pathomechanics and other surgical corrections of the hip.
- 17 March 2017
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 25 (4) , 1125-1131
Reconstructing the anterolateral ligament does not decrease rotational knee laxity in ACL-reconstructed knees
Purpose Little is known about the anterolateral ligament’s (ALL) influence on knee laxity. The purpose of this study was to investigate rotational knee laxity against a pure axial rotational stress using radiostereometric analysis (RSA) after cutting and reconstructing both the anterior cruciate ligament (ACL) and the ALL. Methods Eight human donor legs were positioned and stereoradiographically recorded at 0°, 30° and 60° of knee flexion using a motorised fixture, while an internally rotating force of 4 Nm was applied to the foot. Anterior–posterior and rotational laxity were investigated for knees with intact ligaments and compared with those observed after successive ACL and ALL resection and reconstruction. Results After cutting the ALL in ACL-deficient knees, the internal rotation was increased in all three knee flexion angles, 0° (p = 0.04), 30° (p = 0.03) and 60° (p < 0.01) by 1.0°, 1.6° and 2.5°, respectively. However, no decrease in laxity was found after reconstructing the ALL in ACL-reconstructed knees. Conclusions The ALL was confirmed as a stabiliser of internal rotation in ACL-deficient knees. However, reconstructing the ALL using a gracilis autograft tendon did not decrease the internal rotation laxity in the ACL-reconstructed knee. Based on the results of this study, we do not recommend reconstructing the ALL in ACL-reconstructed knees to decrease internal knee laxity.
- 17 March 2017
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 25 (4) , 1125-1131
Reconstructing the anterolateral ligament does not decrease rotational knee laxity in ACL-reconstructed knees
Purpose Little is known about the anterolateral ligament’s (ALL) influence on knee laxity. The purpose of this study was to investigate rotational knee laxity against a pure axial rotational stress using radiostereometric analysis (RSA) after cutting and reconstructing both the anterior cruciate ligament (ACL) and the ALL. Methods Eight human donor legs were positioned and stereoradiographically recorded at 0°, 30° and 60° of knee flexion using a motorised fixture, while an internally rotating force of 4 Nm was applied to the foot. Anterior–posterior and rotational laxity were investigated for knees with intact ligaments and compared with those observed after successive ACL and ALL resection and reconstruction. Results After cutting the ALL in ACL-deficient knees, the internal rotation was increased in all three knee flexion angles, 0° (p = 0.04), 30° (p = 0.03) and 60° (p < 0.01) by 1.0°, 1.6° and 2.5°, respectively. However, no decrease in laxity was found after reconstructing the ALL in ACL-reconstructed knees. Conclusions The ALL was confirmed as a stabiliser of internal rotation in ACL-deficient knees. However, reconstructing the ALL using a gracilis autograft tendon did not decrease the internal rotation laxity in the ACL-reconstructed knee. Based on the results of this study, we do not recommend reconstructing the ALL in ACL-reconstructed knees to decrease internal knee laxity.