CWChristopher Williamson

Christopher Williamson

*This is an algorithmically generated author record based on publicly available information.

Christopher Williamson has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Centralized Pressure Control and Displacement Quantization with Digital Displacement Pumps

    by Jordan Pascale, Chris Williamson, Jim Hennen, Paul Rindahl

    Danfoss Power Solutions has developed a centralized pressure control solution for multipump hydraulic power units in the industrial market. This system architecture has been developed around the use of the Digital Displacement Pump® (DDP) which is highly efficient over a wide range of operating conditions and has typically shown a >30% decrease in electrical input energy over similar systems using axial piston pumps. MTS Systems expanded this centralized control to work in a harmonized fashion with other pumping technologies housed within unique motor-pump modules; some containing DDP and others containing conventional axial piston pumps. This arrangement provided several benefits and empirically demonstrated the DDP module efficiency over the axial piston pump module in supplying fluid power to dynamic downstream force and motion systems that replicate real-world automotive drive files and test track profiles. Special consideration was required when implementing DDP in a system with multiple pumps' (maximum of 6) outlet flow combined in parallel. Allowing each individual pump controller to operate in pressure control mode caused compounding complexity in tuning, and noisy, unstable flow pulsations. As a solution, a centralized pressure control scheme was implemented in which a system level microcontroller evaluated user inputs, pressure signals from a transducer, executed logic, and output displacement commands to each pump controller as required to meet the system demand. What makes this control scheme unique is that in a multi-pump system, one pump has a continuously variable displacement fraction with any value from 0 to 100%. The other pump displacements were controlled in a quantized manner with stepped values of displacement (for example: 0%, 25%, 75%, 100%). Hose resonant frequencies were also avoided in this manner. Testing and implementation of this control scheme has proven to be effective in reducing system tuning complexity and undesirable flow pulsations in the system. Measured results indicate that the average pressure ripple power was reduced by 28% to 94% and the average pressure ripple band power by 61% to 98% (pump module dependent). Successful implementation of the centralized control allowed MTS to demonstrate through an energy efficiency study that HPUs equipped with DDP consume up to 37.5% less energy than those with swashplate pumps for a given test cycle.

  • The Theoretical Volumetric Displacement of a Check-Valve Type, Digital Displacement Pump

    by Noah Manring, Christopher Williamson

    This paper has been written to develop closed-form equations for describing the theoretical displacement of a check-valve type, digital displacement pump. In theory, the digital displacement pump is used to alter the apparent volumetric displacement of the machine by short circuiting the flow path for reciprocating pistons within the machine that would ordinarily deliver a full volumetric flow rate to the discharge side of the pump. The short circuiting for the pistons is achieved by opening and closing a digital valve connected to each piston chamber at a desired time during the kinematic cycle for each reciprocating piston. Experience with these machines has shown that the expected volumetric displacement for the machine tends to decrease with pressure. This paper presents a theoretical explanation for the reduced volumetric displacement of the pump and quantifies the expected behavior based upon the digital valve command, the residual volume of fluid within a single piston chamber, and the fluid bulk modulus-of-elasticity. In summary, it shown that the apparent volumetric displacement of the machine may be reduced by as much as 10% for high-displacement commands and by as much as 30% for low-displacement commands.