Jose R. Morillas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jose R. Morillas has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Juan de Vicente
F2N2Lab, Magnetic Soft Matter Group, Department of Applied Physics, Faculty of Sciences, University of Granada, C/Fuentenueva s/n, Granada 18071, Spain
25 shared publications - Guillermo Camacho
University of Granada
8 shared publications - Stefania Nardecchia
University of Granada Fuentenueva s/n
6 shared publications - Antonio Jose Faria Bombard
Universidade Federal de Itajubá, Brazil
4 shared publications - Jesús García-Gutiérrez
University of Granada Fuentenueva s/n
4 shared publications - Alejandro Rodriguez-Barroso
University of Granada
3 shared publications
Latest Publications
- Open Access
- 12 November 2026
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 59 (22) , 12750-12763
A Master Curve for Magnetically Tuned Mechanical Hysteresis in Strain-Stiffening, Self-Healing Polysaccharide Hydrogels
Precise control over the mechanical properties of biomimetic hydrogels is critical for applications in biomedicine, tissue engineering, and soft robotics. In this study, we present a strategy to finely tune the mechanical hysteresis of strain-stiffening, self-healing magnetic hydrogels by applying external uniaxial magnetic fields during gelation. The hydrogel network is formed via dynamic covalent imine bonds between chitosan and oxidized hyaluronic acid, while embedded iron microparticles generate anisotropic microstructures under steady magnetic fields, providing directional reinforcement. The mechanical response of the hydrogels is governed by two key parameters: the strain amplitude under oscillatory shear and the strength of the applied magnetic field. By combining magnetostatic finite element simulations with rheological experiments, we define a scaling variable that combines field and strain effects, enabling a master-curve representation. The magnetic hysteresis parameter, ranging from –78.8 to +147.6, quantitatively captures this tunable behavior across strain amplitudes up to 3000% and magnetic field strengths up to 354 kA·m–1. Such predictability allows for the rational design of hydrogels with tailored mechanical responses. Furthermore, short-term in vitro assays with human fibroblasts showed no detectable cytotoxic effects under the conditions tested, providing an initial indication of cytocompatibility and motivating further investigation of these materials for potential biomedical applications.
- 12 November 2026
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 59 (22) , 12750-12763
Open AccessA Master Curve for Magnetically Tuned Mechanical Hysteresis in Strain-Stiffening, Self-Healing Polysaccharide Hydrogels
Precise control over the mechanical properties of biomimetic hydrogels is critical for applications in biomedicine, tissue engineering, and soft robotics. In this study, we present a strategy to finely tune the mechanical hysteresis of strain-stiffening, self-healing magnetic hydrogels by applying external uniaxial magnetic fields during gelation. The hydrogel network is formed via dynamic covalent imine bonds between chitosan and oxidized hyaluronic acid, while embedded iron microparticles generate anisotropic microstructures under steady magnetic fields, providing directional reinforcement. The mechanical response of the hydrogels is governed by two key parameters: the strain amplitude under oscillatory shear and the strength of the applied magnetic field. By combining magnetostatic finite element simulations with rheological experiments, we define a scaling variable that combines field and strain effects, enabling a master-curve representation. The magnetic hysteresis parameter, ranging from –78.8 to +147.6, quantitatively captures this tunable behavior across strain amplitudes up to 3000% and magnetic field strengths up to 354 kA·m–1. Such predictability allows for the rational design of hydrogels with tailored mechanical responses. Furthermore, short-term in vitro assays with human fibroblasts showed no detectable cytotoxic effects under the conditions tested, providing an initial indication of cytocompatibility and motivating further investigation of these materials for potential biomedical applications.
- Open Access
- 24 August 2026
- Published by Elsevier in Biomaterials
- Vol. 338 (Pt A) , 124558
High-frequency magnetic fields for fine tuning particle scaffolds in living self-healing hydrogels
- 24 August 2026
- Published by Elsevier in Biomaterials
- Vol. 338 (Pt A) , 124558
Open AccessHigh-frequency magnetic fields for fine tuning particle scaffolds in living self-healing hydrogels
- Open Access
- 1 July 2026
- Published by Wiley in Advanced Materials
- Vol. 38 (44) , e73847
Engineering Layered Magnetic Hydrogels for Cell Placement via Shear and Magnetic Field‐Induced Assembly
The design of hydrogel‐based artificial tissues capable of reversible, programmed, and complex motions requires both stimuli‐responsiveness and structural anisotropy. In this work, non‐unidirectional anisotropies are generated in biocompatible hydrogels by structuring magnetic particle suspensions into lamellar architectures through two distinct routes: the application of an unsteady magnetic field to a quiescent sample, and the superposition of a steady magnetic field with shear flow. In both approaches, magnetic particles undergo directed self‐assembly within a polymer matrix that subsequently gels, thereby preserving the formed structures. We analyze the assembly kinetics, characterize the resulting lamellar patterns, and construct phase diagrams for each method. The morphology and periodicity of the lamellae are shown to depend strongly on geometric confinement, enabling tunable interlamellar spacing from tens to hundreds of microns. Crucially, it is demonstrated that the resulting layered hydrogels can confine human fibroblasts between adjacent particle‐rich lamellae, maintain cell viability above 95% over 7 days of culture, and promote preferential cell alignment parallel to the layered structures. These findings establish magnetic field‐directed lamellar structuring as a versatile route to anisotropic hydrogels with programmable internal architecture, opening new opportunities in tissue engineering, bioactuation, and soft robotics.
- 1 July 2026
- Published by Wiley in Advanced Materials
- Vol. 38 (44) , e73847
Open AccessEngineering Layered Magnetic Hydrogels for Cell Placement via Shear and Magnetic Field‐Induced Assembly
The design of hydrogel‐based artificial tissues capable of reversible, programmed, and complex motions requires both stimuli‐responsiveness and structural anisotropy. In this work, non‐unidirectional anisotropies are generated in biocompatible hydrogels by structuring magnetic particle suspensions into lamellar architectures through two distinct routes: the application of an unsteady magnetic field to a quiescent sample, and the superposition of a steady magnetic field with shear flow. In both approaches, magnetic particles undergo directed self‐assembly within a polymer matrix that subsequently gels, thereby preserving the formed structures. We analyze the assembly kinetics, characterize the resulting lamellar patterns, and construct phase diagrams for each method. The morphology and periodicity of the lamellae are shown to depend strongly on geometric confinement, enabling tunable interlamellar spacing from tens to hundreds of microns. Crucially, it is demonstrated that the resulting layered hydrogels can confine human fibroblasts between adjacent particle‐rich lamellae, maintain cell viability above 95% over 7 days of culture, and promote preferential cell alignment parallel to the layered structures. These findings establish magnetic field‐directed lamellar structuring as a versatile route to anisotropic hydrogels with programmable internal architecture, opening new opportunities in tissue engineering, bioactuation, and soft robotics.
- Open Access
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
High-frequency Magnetic Fields for Fine Tuning Particle Scaffolds in Living Self-healing Hydrogels
Living tissues exhibit a complex, anisotropic, and hierarchical organization. Replicating cellular alignment within a biomimetic extracellular matrix remains a significant challenge, particularly in hydrogels, whose randomly crosslinked polymer networks inherently form isotropic structures. Here, we present an innovative approach for engineering biocompatible structured hydrogels using magnetic particles under previously unexplored high-frequency magnetic fields. By applying an unsteady triaxial magnetic field, we induce anisotropic structural self-assembly in a hydrogel precursor solution composed of oxidized-laminarin and gelatin. Upon gelation, the external field can be removed, leaving a stabilized three-dimensional particle structure. This structure, in turn, provides directional cues for guided cell alignment, migration and growth. The ability to structure hydrogels in their liquid phase opens new possibilities for minimally invasive, in situ cell regeneration therapies based on injectable, self-healing formulations.
- 22 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHigh-frequency Magnetic Fields for Fine Tuning Particle Scaffolds in Living Self-healing Hydrogels
Living tissues exhibit a complex, anisotropic, and hierarchical organization. Replicating cellular alignment within a biomimetic extracellular matrix remains a significant challenge, particularly in hydrogels, whose randomly crosslinked polymer networks inherently form isotropic structures. Here, we present an innovative approach for engineering biocompatible structured hydrogels using magnetic particles under previously unexplored high-frequency magnetic fields. By applying an unsteady triaxial magnetic field, we induce anisotropic structural self-assembly in a hydrogel precursor solution composed of oxidized-laminarin and gelatin. Upon gelation, the external field can be removed, leaving a stabilized three-dimensional particle structure. This structure, in turn, provides directional cues for guided cell alignment, migration and growth. The ability to structure hydrogels in their liquid phase opens new possibilities for minimally invasive, in situ cell regeneration therapies based on injectable, self-healing formulations.
- Open Access
- 13 February 2025
- Published by American Physical Society (APS) in Physical Review E
- Vol. 111 (2) , 025415
High-speed videomicroscopy and magnetorheology under triaxial unsteady magnetic fields
We describe a custom-built device that is capable of superimposing triaxial unsteady magnetic fields on a sample at the same time that its microstructure is visualized using a high-speed camera and its rheological properties are measured with a commercial rheometer. The device reaches field strengths up to 5 kA · m − 1 , frequencies up to 4 kHz, and its functionality is evaluated by testing magnetorheological fluids under steady shear flow and field transients. Striking differences are found at small Mason numbers by changing the field configuration.
- 13 February 2025
- Published by American Physical Society (APS) in Physical Review E
- Vol. 111 (2) , 025415
Open AccessHigh-speed videomicroscopy and magnetorheology under triaxial unsteady magnetic fields
We describe a custom-built device that is capable of superimposing triaxial unsteady magnetic fields on a sample at the same time that its microstructure is visualized using a high-speed camera and its rheological properties are measured with a commercial rheometer. The device reaches field strengths up to 5 kA · m − 1 , frequencies up to 4 kHz, and its functionality is evaluated by testing magnetorheological fluids under steady shear flow and field transients. Striking differences are found at small Mason numbers by changing the field configuration.
- Open Access
- 29 July 2024
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 6 (3) , 033115
Double-gap bicone magnetorheology in steady shear under homogeneous magnetic and flow fields
We design, fabricate, and test a double-gap bicone magnetorheological (MR) device to measure steady shear rheological properties of MR fluids under saturating magnetic fields (i.e., large enough to saturate the MR fluids). The device is optimized using finite element method and computational fluid dynamics simulations so that homogeneous, saturating field strengths are reached while keeping a constant shear rate within the main shearing gaps. Experiments demonstrate that the flow curves in the saturation regime can be fitted to a viscoplastic Casson model in good agreement with MR fluids under much lower (nonsaturating) fields. Moreover, yield stress data follow a linear dependence on volume fraction at low particle loadings, in agreement with existing theoretical models. Published by the American Physical Society 2024
- 29 July 2024
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 6 (3) , 033115
Open AccessDouble-gap bicone magnetorheology in steady shear under homogeneous magnetic and flow fields
We design, fabricate, and test a double-gap bicone magnetorheological (MR) device to measure steady shear rheological properties of MR fluids under saturating magnetic fields (i.e., large enough to saturate the MR fluids). The device is optimized using finite element method and computational fluid dynamics simulations so that homogeneous, saturating field strengths are reached while keeping a constant shear rate within the main shearing gaps. Experiments demonstrate that the flow curves in the saturation regime can be fitted to a viscoplastic Casson model in good agreement with MR fluids under much lower (nonsaturating) fields. Moreover, yield stress data follow a linear dependence on volume fraction at low particle loadings, in agreement with existing theoretical models. Published by the American Physical Society 2024
- 29 July 2024
- Published by Springer Nature
- p. 109-112
Thixotropic Behavior of Self-healing Magnetic Hydrogels
- 29 July 2024
- Published by Springer Nature
- p. 109-112
Thixotropic Behavior of Self-healing Magnetic Hydrogels
- 29 July 2024
- Published by Springer Nature
- p. 169-172
High-Speed Rheo-Microscopy in Magnetorheological Fluids Under Triaxial Unsteady Magnetic Fields
- 29 July 2024
- Published by Springer Nature
- p. 169-172
High-Speed Rheo-Microscopy in Magnetorheological Fluids Under Triaxial Unsteady Magnetic Fields
- 24 October 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 20 (4) , 044063
Generation of synchronized high-frequency triaxial magnetic fields using fractal capacitor banks
Magnetic field generators with the ability to create well-controlled dynamic fields in arbitrary directions are an essential tool to investigate magnetic soft matter and to drive (sub)micrometer structures to targeted locations. In this article we present the design and performance of a triaxial generator based on three fractal capacitor banks that enable real-time control of the output field and a quasi-continuous distribution of resonant frequencies up to 4 kHz. The increased field strength over the entire frequency range will enhance the response of magnetorheological fluids as well as the velocity and load capacity of magnetic swarms that, in recent years, have made the leap from in vitro to in vivo studies of targeted drug delivery.
- 24 October 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 20 (4) , 044063
Generation of synchronized high-frequency triaxial magnetic fields using fractal capacitor banks
Magnetic field generators with the ability to create well-controlled dynamic fields in arbitrary directions are an essential tool to investigate magnetic soft matter and to drive (sub)micrometer structures to targeted locations. In this article we present the design and performance of a triaxial generator based on three fractal capacitor banks that enable real-time control of the output field and a quasi-continuous distribution of resonant frequencies up to 4 kHz. The increased field strength over the entire frequency range will enhance the response of magnetorheological fluids as well as the velocity and load capacity of magnetic swarms that, in recent years, have made the leap from in vitro to in vivo studies of targeted drug delivery.
- 21 February 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 19 (2) , L021001
Experimental Realization of a Colloidal Ratchet Effect in a non-Newtonian Fluid
Shear thinning fluids represent a class of non-Newtonian media characterized by a decrease of the apparent viscosity when increasing the shear rate. Here we experimentally demonstrate a deterministic ratchet effect in such media that enables directed transport of microscopic particles under a square-wave magnetic force. The applied modulation is designed in such a way that it does not produce any average speed when the particles are dispersed in a Newtonian fluid (e.g., water). However, in a dilute biopolymer solution, we observe the emergence of a net colloidal current when the forcing wave is composed of different amplitudes and time durations within a single period. The shear thinning nature of the dispersing medium nonlinearly raises the mean speed for strong forces, breaking the spatial symmetry of the particle displacement and generating a net colloidal transport. We complement our findings with numerical simulations that capture well the underlying physical mechanism, showing good agreement with the experimental results. Our technique to ratchet magnetic particles could be potentially extended in active microrheology to probe other non-Newtonian, complex fluids and to infer the nonlinear properties of viscoelastic materials.
- 21 February 2023
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 19 (2) , L021001
Experimental Realization of a Colloidal Ratchet Effect in a non-Newtonian Fluid
Shear thinning fluids represent a class of non-Newtonian media characterized by a decrease of the apparent viscosity when increasing the shear rate. Here we experimentally demonstrate a deterministic ratchet effect in such media that enables directed transport of microscopic particles under a square-wave magnetic force. The applied modulation is designed in such a way that it does not produce any average speed when the particles are dispersed in a Newtonian fluid (e.g., water). However, in a dilute biopolymer solution, we observe the emergence of a net colloidal current when the forcing wave is composed of different amplitudes and time durations within a single period. The shear thinning nature of the dispersing medium nonlinearly raises the mean speed for strong forces, breaking the spatial symmetry of the particle displacement and generating a net colloidal transport. We complement our findings with numerical simulations that capture well the underlying physical mechanism, showing good agreement with the experimental results. Our technique to ratchet magnetic particles could be potentially extended in active microrheology to probe other non-Newtonian, complex fluids and to infer the nonlinear properties of viscoelastic materials.