GCGuillermo Camacho

Guillermo Camacho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guillermo Camacho has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-frequency magnetic fields for fine tuning particle scaffolds in living self-healing hydrogels

    by S. Nardecchia, J. García-Gutiérrez, G. Camacho, J.R. Morillas, M. Terkel, J. de Vicente


  • Open Access

    Engineering Layered Magnetic Hydrogels for Cell Placement via Shear and Magnetic Field‐Induced Assembly

    by Guillermo Camacho, Jose R. Morillas, Jesús García‐Gutiérrez, Stefania Nardecchia, Óscar Martínez‐Cano, Juan de Vicente

    The design of hydrogel‐based artificial tissues capable of reversible, programmed, and complex motions requires both stimuli‐responsiveness and structural anisotropy. In this work, non‐unidirectional anisotropies are generated in biocompatible hydrogels by structuring magnetic particle suspensions into lamellar architectures through two distinct routes: the application of an unsteady magnetic field to a quiescent sample, and the superposition of a steady magnetic field with shear flow. In both approaches, magnetic particles undergo directed self‐assembly within a polymer matrix that subsequently gels, thereby preserving the formed structures. We analyze the assembly kinetics, characterize the resulting lamellar patterns, and construct phase diagrams for each method. The morphology and periodicity of the lamellae are shown to depend strongly on geometric confinement, enabling tunable interlamellar spacing from tens to hundreds of microns. Crucially, it is demonstrated that the resulting layered hydrogels can confine human fibroblasts between adjacent particle‐rich lamellae, maintain cell viability above 95% over 7 days of culture, and promote preferential cell alignment parallel to the layered structures. These findings establish magnetic field‐directed lamellar structuring as a versatile route to anisotropic hydrogels with programmable internal architecture, opening new opportunities in tissue engineering, bioactuation, and soft robotics.


  • Open Access

    High-frequency Magnetic Fields for Fine Tuning Particle Scaffolds in Living Self-healing Hydrogels

    by S. Nardecchia, J. García-Gutiérrez, G. Camacho, J. R. Morillas, M. Terkel, Juan De Vicente

    Living tissues exhibit a complex, anisotropic, and hierarchical organization. Replicating cellular alignment within a biomimetic extracellular matrix remains a significant challenge, particularly in hydrogels, whose randomly crosslinked polymer networks inherently form isotropic structures. Here, we present an innovative approach for engineering biocompatible structured hydrogels using magnetic particles under previously unexplored high-frequency magnetic fields. By applying an unsteady triaxial magnetic field, we induce anisotropic structural self-assembly in a hydrogel precursor solution composed of oxidized-laminarin and gelatin. Upon gelation, the external field can be removed, leaving a stabilized three-dimensional particle structure. This structure, in turn, provides directional cues for guided cell alignment, migration and growth. The ability to structure hydrogels in their liquid phase opens new possibilities for minimally invasive, in situ cell regeneration therapies based on injectable, self-healing formulations.

  • Open Access

    Template-Free Ultrafast Directed Self-Assembly Using Biaxial Toggled Magnetic Fields

    by Guillermo Camacho, Juan de Vicente

    Speeding up the directed self-assembly of functional nanomaterials is a rapidly advancing area of research. Traditional self-assembly methods can be slow and limited by kinetic barriers. In this study, we demonstrate that the process can be dramatically accelerated for magnetic colloids when biaxial toggled magnetic fields (BTFs) are used. In this field configuration, a transversal pulsed magnetic field is superimposed perpendicular to the primary toggled magnetic field, facilitating faster phase separation in a model magnetic colloid. This approach offers enhanced control over aggregation dynamics by adjusting the field's frequency and intensity and does not require any physical templates. Beyond structure control, the aggregation kinetics can also be precisely tuned. Within the context of magnetic materials, this method enables the formation of diverse and tunable structures such as chains, columns, depercolated aggregates, and percolating bands. BTFs further promote the formation of highly crystalline domains, enhancing the properties of the resulting self-assembled materials. While this technique is specifically tailored for magnetic systems, its versatility makes it relevant for the design and fabrication of functional nanomaterials. The ability to tune aggregation kinetics and achieve a range of structures may be beneficial for applications in photonics, electronics, and biomedicine.


  • Continuous Frequency Sweeping Magnetorheometry Based on Variable Inductance

    by Alejandro Rodriguez-Barroso, Javier Ruiz-Nievas, Jose Carlos Ruiz-Pelegrina, Oscar Martinez-Cano, Guillermo Camacho, Juan de Vicente

    Self-assembly of magnetic colloidal particles into pre-programed microstructures plays an important role in the design of functional soft materials of interest in the microfabrication of sensors, actuators and/or tissue engineering applications. Particle aggregates emerge because of a delicate balance between magnetic interparticle interactions and hydrodynamic interactions with the carrier. These aggregates are dynamic and follow the field when its frequency is small enough. However, for sufficiently large field frequencies the particles within the aggregates experience a time-averaged magnetic interaction that results in the formation of static (i.e. arrested) gel-like structures. The transition between the dynamic and static state is not well understood because strong fields are needed to continuously vary their frequency in a wide range. Current approaches that rely on capacitor banks require periodically turning off field generation to prevent current and voltage spikes when switching circuit relays, which disrupts the gel-like structure. These unwanted alterations in the sample’s microstructure introduce perturbations in the measurements, rendering them unreliable. In this study, we propose an inductance approach that operates at resonance, eliminating the need for switching-off periods during frequency sweeps while enabling precise control of the phase lag between the applied voltage and the generated magnetic field. This method requires continuous inductance adjustment and allows direct comparison with interrupted systems, demonstrating that field interruptions exceeding 20% duty cycle significantly affect rheological measurements. Furthermore, videomicroscopy and rheometry are employed to investigate the transition between dynamic and static behavior, as well as to monitor microstructural evolution and rheological properties under oscillatory shear. These high-precision measurements facilitate the advancement of smart and biological material design and synthesis, enhance frequency control of microrobots for medical applications, and improve both the speed and resolution of active rheometry techniques.

  • Speeding the directed self-assembly under toggled magnetic fields

    by Guillermo Camacho, Juan de Vicente

    Toggled field self-assembly is a useful way to circumvent kinetic arrest of the induced structures in field-directed self-assembly and, in particular, in magnetic suspensions such as magnetorheological (MR) fluids. During the field-off period, Brownian motion permits rearrangement of the particles and classical system-spanning chains (typically formed under uniaxial DC fields) collapse into dense ellipsoidal aggregates that are more energetically favorable. Here we show, through the use of experiments and particle-level simulations, that the process is very sensitive to the field configuration (e.g., frequency and strength), and, in particular, it can be dramatically accelerated when the magnetic field strength is increased. Moreover, when the field strength reaches sufficiently high values, the classical two-step aggregation process becomes a single one and morphological differences in the final structures emerge.


  • Open Access

    High-speed videomicroscopy and magnetorheology under triaxial unsteady magnetic fields

    by O. Martínez-Cano, J. R. Morillas, J. Ruiz-Nievas, G. Camacho, A. Rodríguez-Barroso, J. Ramírez, J. de Vicente

    We describe a custom-built device that is capable of superimposing triaxial unsteady magnetic fields on a sample at the same time that its microstructure is visualized using a high-speed camera and its rheological properties are measured with a commercial rheometer. The device reaches field strengths up to 5 kA · m − 1 , frequencies up to 4 kHz, and its functionality is evaluated by testing magnetorheological fluids under steady shear flow and field transients. Striking differences are found at small Mason numbers by changing the field configuration.


  • Open Access

    Double-gap bicone magnetorheology in steady shear under homogeneous magnetic and flow fields

    by Guillermo Camacho, Juan de Vicente, Jose R. Morillas

    We design, fabricate, and test a double-gap bicone magnetorheological (MR) device to measure steady shear rheological properties of MR fluids under saturating magnetic fields (i.e., large enough to saturate the MR fluids). The device is optimized using finite element method and computational fluid dynamics simulations so that homogeneous, saturating field strengths are reached while keeping a constant shear rate within the main shearing gaps. Experiments demonstrate that the flow curves in the saturation regime can be fitted to a viscoplastic Casson model in good agreement with MR fluids under much lower (nonsaturating) fields. Moreover, yield stress data follow a linear dependence on volume fraction at low particle loadings, in agreement with existing theoretical models. Published by the American Physical Society 2024


  • High-Speed Rheo-Microscopy in Magnetorheological Fluids Under Triaxial Unsteady Magnetic Fields

    by G. Camacho, O. Martínez-Cano, J. R. Morillas, J. Ruiz-Nievas, A. Rodríguez-Barroso, J. Ramírez, J. de Vicente

  • Open Access

    Magnetophoretic force and homogeneity optimization in multiplexed magnetic tweezers for microrheometry applications

    by Alejandro Rodriguez-Barroso, Guillermo Camacho, Oscar Martinez-Cano, Jose Rafael Morillas, Juan de Vicente