AHAndreas Spandet Havreland

Andreas Spandet Havreland

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andreas Spandet Havreland has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Hand-Held 190+190 Row–Column Addressed CMUT Probe for Volumetric Imaging

    by Rune Sixten Grass, Mathias Engholm, Andreas Spandet Havreland, Christopher Beers, Martin Lind Ommen, Stine Lovholt Grue Pedersen, Lars Nordahl Moesner, Matthias Bo Stuart, Mudabbir Tufail Bhatti, Borislav G. Tomov, et al.

    This paper presents the design, fabrication, and characterization of a 190+190 row-column addressed (RCA) capacitive micromachined ultrasonic transducer (CMUT) array integrated in a custom hand-held probe handle. The array has a designed 4.5 MHz center frequency in immersion and a pitch of $95~\mu $ m which corresponds to $\approx ~\lambda $ /4. The array has a $2.14\times2.14$ cm $^{2}$ footprint including an integrated apodization scheme to reduce ghost echoes when performing ultrasound imaging. The array was fabricated using a combination of fusion and anodic bonding, and a deposit, remove, etch, multistep (DREM) etch to reduce substrate coupling and improve electrode conductivity. The transducer array was wire-bonded to a rigid-flex printed circuit board (PCB), encapsulated in room temperature vulcanizing (RTV) silicone polymer, electromagnetic interference (EMI) shielded, and mounted in a 3D-milled PPSU probe handle. The probe was characterized using the SARUS experimental scanner and 3D volumetric imaging was demonstrated on scatter and wire phantoms. The imaging depth was derived from tissue mimicking phantom measurements (0.5 dB MHz $^{-1} \text{cm}^{-1}$ attenuation) by estimating the SNR at varying depths. For a synthetic aperture imaging sequence with 96+96 emissions the imaging depth was 3.6 cm. The center frequency measured from the impulse response spectra in transmit and pulse-echo was 6.0 ± 0.9 MHz and 5.3 ± 0.4 MHz, and the corresponding relative bandwidths were 62.8 ± 4.5 % and 86.2 ± 10.4 %. The fabrication process showed clear improvement in relative receive sensitivity and transmit pressure uniformity compared to earlier silicon-on-insulator (SOI) based designs. However, at the same time it presented yield problems resulting in only around 55 % elements with a good response.


  • Analytical Deflection Profiles and Pull-In Voltage Calculations of Prestressed Electrostatic Actuated MEMS Structures

    by Andreas Spandet Havreland, Erik Vilain Thomsen

    This paper presents a zeroth and first order perturbative analysis of prestressed electrostatic actuated Microelectromechanical systems (MEMS). Perturbation theory is used to calculate the deflection profile of various MEMS structures, from which the pull-in voltage is estimated using the weighed residual method, where both a Galerkin expression and a Dirac delta function have been used as weight functions. A prestressed circular Capacitative Micromachined Ultrasonic Transducer (CMUT) is used as the main example in this paper. This device is modeled as a circular clamped plate subjected to an electrostatic pressure. The calculated pull-in voltage has been compared with experimental data of highly prestressed CMUTs, where a relative error between -36% and -8% is observed for a model that does not include stress. The model that includes the residual stress lowers the range of the relative error to values between -5% and 21%. To improve the accuracy of the pull-in voltage estimate Richardson extrapolation has been calculated from the zeroth and first order estimates. The pull-in voltage models are compared with a Finite Element Model (FEM), where an overestimation, in the high stress regime, of 10% is observed for the zeroth order model, less than 5% for the Galerkin method and 3% for the Richardson extrapolation. [2020-0358]


  • CMUT Electrode Resistance Design: Modeling and Experimental Verification by a Row-Column Array

    by Andreas Spandet Havreland, Mathias Engholm, Borislav Gueorguiev Tomov, Jorgen Arendt Jensen, Ole Hansen, Erik Vilain Thomsen

    This paper addresses the importance of having control over the resistivity of the electrodes for capacitive micromachined ultrasonic transducers (CMUT) devices. The electrode resistivity can vary depending on the fabrication technology used, and resistivity control becomes especially important in the cases where metal electrodes can not be used. This raises the question: When is the resistivity of an electrode sufficiently low? To answer this question we have developed a simple design criterion. The criterion describes the attenuation of AC signals along a CMUT element. It is shown that the non-dimensional product between angular excitation frequency, resistance, and capacitance ωRC of an element has to be smaller than 0.35 to ensure an AC potential drop along the element of less than 1%. The optimal magnitude and directionality of the transmit pressure will be achieved if CMUT elements are designed according to the developed criteria. Hence, the model can be used to estimate device parameters that will ensure the CMUT is suitable for generating ultrasound images. An example is given where the model is used to predict the required electrode thickness for structured electrodes made of Gold, Aluminium, and Indium-Tin-Oxide, respectively. To verify the model, two Row-Column addressed (RCA) CMUT transducers were used to illustrate the effect of high and low electrode resistivity. One transducer had a sufficient electrode resistivity, and the other had an insufficient electrode resistivity. The RCA CMUT transducers were fabricated using fusion bonding, where the top electrode is made of aluminium and the bottom electrode is made of doped silicon. The resistivity of the aluminium top electrode is 2×10-6 Ωcm for both transducers, whereas the resistivity for the bottom electrode is 0.1 Ωcm for the first transducer and 0.005 Ωcm for the second transducer. The transducer with low resistivity emits pressure uniformly along both the rows and columns, whereas the transmit pressure field from the other transducer has a uniformly distributed pressure field along the rows, but a decreasing pressure field along the columns due to the high resistivity in the bottom electrode. The pressure drop, along the columns is frequency dependent and has been observed to be 63%, 74%, and 82% for the excitation frequencies 2 MHz, 4.5 MHz, and 7 MHz, respectively.


  • Micro-fabricated all optical pressure sensors

    by Andreas Spandet Havreland, Søren Dahl Petersen, Christian Østergaard, Kasper Reck-Nielsen, Erik Vilain Thomsen