Guoliang Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guoliang Xu has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Rui Ding
Institute of Plasma Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, People’s Republic of China
12 shared publications Junling Chen
Institute of Plasma Physics
10 shared publicationsHui Wang
Institute of Plasma Physics
6 shared publicationsHai Xie
Institute of Plasma Physics
5 shared publicationsDahuan Zhu
Chinese Acad Sci, Inst Plasma Phys, Hefei Inst Phys Sci, Hefei, Peoples R China
4 shared publications- Guozhang Jia
Chinese Acad Sci, Inst Plasma Phys, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
4 shared publications
Latest Publications
- Open Access
- 8 September 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (10) , 106041
Simulation study of tungsten erosion and impurity transport under the assumption of a full-tungsten wall in EAST plasmas
Future fusion reactors are expected to employ full-tungsten plasma-facing components (PFCs), and the generation and core accumulation of tungsten impurities under full-tungsten wall environment is one of the key issues that limit the stable operation of tokamak devices. In this work, the upgraded impurity transport code IMPEDGE is coupled with the extended-grid version of SOLPS-ITER to investigate the erosion and transport of tungsten impurity in full-tungsten wall environment. The background plasma in our simulation is based on experimental data from EAST discharge #140718, with all PFCs assumed to be tungsten. The simulations show that, under full-tungsten wall assumption, both the tungsten impurity erosion and its core concentration remain at relatively high levels even in the detached regime, with dominant contributions originating from the far scrape-off layer (far-SOL) of the lower divertor and the upper divertor region. The main reason is that, although the electron temperature at the near SOL (near-SOL) of the lower divertor decreases significantly during detachment, that in the far-SOL region remains difficult to further reduce (∼10 eV), resulting in substantial tungsten erosion. The total impurity penetration probability (defined as the probability for emitted particles to enter the plasma core) also remains at a relatively high level, mainly because the lower plasma density in the far-SOL weakens the impurity screening effect. In the downstream region, the reduced ion density decreases the friction force acting on impurities, allowing them to more easily escape from the region and migrate upstream. In the upstream region, the lower electron density increases the ionization mean free path, causing impurities to be ionized closer to the last closed flux surface and thereby enhancing impurity penetration. These results indicate that impurity screening in the near-SOL divertor region can be significantly enhanced by impurity-seeded detachment. However, erosion and penetration from the far-SOL region still dominate the core impurity accumulation, suggesting that more effective impurity control strategies for the far-SOL region are required in future studies.
- 8 September 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (10) , 106041
Open AccessSimulation study of tungsten erosion and impurity transport under the assumption of a full-tungsten wall in EAST plasmas
Future fusion reactors are expected to employ full-tungsten plasma-facing components (PFCs), and the generation and core accumulation of tungsten impurities under full-tungsten wall environment is one of the key issues that limit the stable operation of tokamak devices. In this work, the upgraded impurity transport code IMPEDGE is coupled with the extended-grid version of SOLPS-ITER to investigate the erosion and transport of tungsten impurity in full-tungsten wall environment. The background plasma in our simulation is based on experimental data from EAST discharge #140718, with all PFCs assumed to be tungsten. The simulations show that, under full-tungsten wall assumption, both the tungsten impurity erosion and its core concentration remain at relatively high levels even in the detached regime, with dominant contributions originating from the far scrape-off layer (far-SOL) of the lower divertor and the upper divertor region. The main reason is that, although the electron temperature at the near SOL (near-SOL) of the lower divertor decreases significantly during detachment, that in the far-SOL region remains difficult to further reduce (∼10 eV), resulting in substantial tungsten erosion. The total impurity penetration probability (defined as the probability for emitted particles to enter the plasma core) also remains at a relatively high level, mainly because the lower plasma density in the far-SOL weakens the impurity screening effect. In the downstream region, the reduced ion density decreases the friction force acting on impurities, allowing them to more easily escape from the region and migrate upstream. In the upstream region, the lower electron density increases the ionization mean free path, causing impurities to be ionized closer to the last closed flux surface and thereby enhancing impurity penetration. These results indicate that impurity screening in the near-SOL divertor region can be significantly enhanced by impurity-seeded detachment. However, erosion and penetration from the far-SOL region still dominate the core impurity accumulation, suggesting that more effective impurity control strategies for the far-SOL region are required in future studies.
- Open Access
- 20 May 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (6) , 066020
The role of kinetic effects on the tungsten impurity transport in the boundary plasma of EAST
A kinetic impurity transport model has been implemented in the Monte-Carlo code DIVIMP to investigate W transport in the boundary plasma of EAST under varied divertor conditions. Background plasmas representing high-recycling and detached divertor conditions with D ₂ and Ne injection in low-confinement mode (L-mode) and high-confinement mode (H-mode) plasmas are provided by the SOLPS simulations, and W transport is then simulated with the DIVIMP code. The inclusion of kinetic effects is found to significantly reduce the W thermal force compared to the conventional fluid model, not only in low collisionality ( ν * < 20) conditions, but also in low ion temperature ( T i ) and high effective charge ( Z eff ) conditions. As the divertor condition varies from the high-recycling to the detached regime with Ne injection, kinetic effects on divertor W retention are enhanced by the decrease of ion temperature and the increase of effective charge. In high-density H-mode plasmas, the kinetic correction on the W thermal force is weaker than in low-density L-mode plasmas. However, the strong friction force in the high-density H-mode cases makes the influence of kinetic effects on W retention more significant, resulting in a reduction of core W density by more than two orders of magnitude. In addition, comparisons with the original Garching flux-limit correction in DIVIMP show that the flux-limit overestimates W thermal force and core W density, especially under impurity seeding conditions. Therefore, explicit kinetic modeling of the thermal force is required for accurate description of W transport in the boundary plasma of tokamaks.
- 20 May 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (6) , 066020
Open AccessThe role of kinetic effects on the tungsten impurity transport in the boundary plasma of EAST
A kinetic impurity transport model has been implemented in the Monte-Carlo code DIVIMP to investigate W transport in the boundary plasma of EAST under varied divertor conditions. Background plasmas representing high-recycling and detached divertor conditions with D ₂ and Ne injection in low-confinement mode (L-mode) and high-confinement mode (H-mode) plasmas are provided by the SOLPS simulations, and W transport is then simulated with the DIVIMP code. The inclusion of kinetic effects is found to significantly reduce the W thermal force compared to the conventional fluid model, not only in low collisionality ( ν * < 20) conditions, but also in low ion temperature ( T i ) and high effective charge ( Z eff ) conditions. As the divertor condition varies from the high-recycling to the detached regime with Ne injection, kinetic effects on divertor W retention are enhanced by the decrease of ion temperature and the increase of effective charge. In high-density H-mode plasmas, the kinetic correction on the W thermal force is weaker than in low-density L-mode plasmas. However, the strong friction force in the high-density H-mode cases makes the influence of kinetic effects on W retention more significant, resulting in a reduction of core W density by more than two orders of magnitude. In addition, comparisons with the original Garching flux-limit correction in DIVIMP show that the flux-limit overestimates W thermal force and core W density, especially under impurity seeding conditions. Therefore, explicit kinetic modeling of the thermal force is required for accurate description of W transport in the boundary plasma of tokamaks.
- Open Access
- 2 December 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (1) , 016039
Damage evolution and its impact of the W/Cu flat-type component for divertor target in EAST
W/Cu flat-type components are promising candidates for plasma-facing components in future fusion devices due to their flexible and efficient heat sink design. They are expected to be used in the inner/outer Reflector plates and Dome of ITER. To investigate their damage behaviors, a high-resolution infrared camera was employed to monitor the damaged C4 W/Cu flat-type component with a hypervapotron heat sink, located in the outer horizontal target (OHT) of the EAST lower divertor. The results show that the formation of W protrusions (‘Hills’) connects the early crack initiation stage with the final W exfoliation. To prevent further damage progression, it is recommended that for tokamaks, the damaged area be located two decay lengths away from the strike point—this distance is sufficient to guarantee safety. In such a scenario, if the damage lies within the private flux region, the parallel heat flux will be reduced to nearly zero. Although thermal performance degraded over time, the damaged OHT component was still able to maintain an approximate thermal equilibrium during each discharge, and no abnormal W impurity levels were observed. Linear fitting analysis estimates a total lifetime of approximately 3257 ± 277 shots, with a plasma stored energy of 298 ± 20 kJ corresponding to the onset of W melting in the surface protrusions. These findings shed light on the damage behavior of W/Cu flat-type components, provide key support for the development and validation of finite element analysis models, and offer practical guidance for the design and evaluation of ITER-like W/Cu flat-type components.
- 2 December 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (1) , 016039
Open AccessDamage evolution and its impact of the W/Cu flat-type component for divertor target in EAST
W/Cu flat-type components are promising candidates for plasma-facing components in future fusion devices due to their flexible and efficient heat sink design. They are expected to be used in the inner/outer Reflector plates and Dome of ITER. To investigate their damage behaviors, a high-resolution infrared camera was employed to monitor the damaged C4 W/Cu flat-type component with a hypervapotron heat sink, located in the outer horizontal target (OHT) of the EAST lower divertor. The results show that the formation of W protrusions (‘Hills’) connects the early crack initiation stage with the final W exfoliation. To prevent further damage progression, it is recommended that for tokamaks, the damaged area be located two decay lengths away from the strike point—this distance is sufficient to guarantee safety. In such a scenario, if the damage lies within the private flux region, the parallel heat flux will be reduced to nearly zero. Although thermal performance degraded over time, the damaged OHT component was still able to maintain an approximate thermal equilibrium during each discharge, and no abnormal W impurity levels were observed. Linear fitting analysis estimates a total lifetime of approximately 3257 ± 277 shots, with a plasma stored energy of 298 ± 20 kJ corresponding to the onset of W melting in the surface protrusions. These findings shed light on the damage behavior of W/Cu flat-type components, provide key support for the development and validation of finite element analysis models, and offer practical guidance for the design and evaluation of ITER-like W/Cu flat-type components.
- 23 July 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (7) , 075034
Modeling the effects of wall particle recycling on divertor detachment and upstream SOL density flattening in HL-2A by SOLPS-ITER
This work employs the SOLPS-ITER code package to investigate the impact of wall particle recycling (WPR) on diverter detachment and upstream scrape-off layer (SOL) density flattening in the HL-2 A with a long-leg closed diverter. The results demonstrate that increasing WPR enhances upstream SOL plasma density, facilitating detachment in the HL-2 A closed diverter by increasing target plasma density, neutral density and radiation loss. In contrast, WPR minimally affects the relatively open diverter, primarily due to its weaker detachment capability. Besides, in this study, we demonstrate that WPR can significantly contribute to upstream density flattening, thereby facilitating the suppression of larger edge localized modes in both closed and open diverter configurations. However, the physical mechanisms governing the flattening upstream SOL density differ between the two diverters: the closed diverter upstream SOL density flattening, reducing pedestal radial density gradient mainly through reverse parallel flow arising from a strong ionization source in closed diverter region, while the open diverter upstream SOL density flattening by diverter region recycling neutral particle reflecting due to the weak recycling particle trapping capability.
- 23 July 2025
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 67 (7) , 075034
Modeling the effects of wall particle recycling on divertor detachment and upstream SOL density flattening in HL-2A by SOLPS-ITER
This work employs the SOLPS-ITER code package to investigate the impact of wall particle recycling (WPR) on diverter detachment and upstream scrape-off layer (SOL) density flattening in the HL-2 A with a long-leg closed diverter. The results demonstrate that increasing WPR enhances upstream SOL plasma density, facilitating detachment in the HL-2 A closed diverter by increasing target plasma density, neutral density and radiation loss. In contrast, WPR minimally affects the relatively open diverter, primarily due to its weaker detachment capability. Besides, in this study, we demonstrate that WPR can significantly contribute to upstream density flattening, thereby facilitating the suppression of larger edge localized modes in both closed and open diverter configurations. However, the physical mechanisms governing the flattening upstream SOL density differ between the two diverters: the closed diverter upstream SOL density flattening, reducing pedestal radial density gradient mainly through reverse parallel flow arising from a strong ionization source in closed diverter region, while the open diverter upstream SOL density flattening by diverter region recycling neutral particle reflecting due to the weak recycling particle trapping capability.
- Open Access
- 31 January 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (2) , 026069
Modeling of hydrogen isotope effect on divertor detachment in EAST
The two-dimensional edge plasma code SOLPS-ITER have been used to study the hydrogen isotope effect on the divertor detachment onset for hydrogen (H), deuterium (D), and tritium (T) based on EAST plasma conditions. Results prove that H with a lighter mass has a stronger ability to penetrate into the core plasma than D and T, resulting in a higher density in the core and a lower density in the SOL. If the line-averaged electron density is selected to characterize the detachment onset, the hydrogen isotope effect is strongly dependent on the measurement chord location which determines the contribution of the core electron density to the line-averaged electron density. The modeling results can explain previous hydrogen isotope experimental results in JET. The drifts effect on hydrogen isotope distributions has also been investigated. As the drifts are taken into account, the relative difference of detachment onset at the outer target becomes larger, while it becomes smaller for the inner target. The E × B drifts show a greater impact on the T ion distribution than D and H ions.
- 31 January 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (2) , 026069
Open AccessModeling of hydrogen isotope effect on divertor detachment in EAST
The two-dimensional edge plasma code SOLPS-ITER have been used to study the hydrogen isotope effect on the divertor detachment onset for hydrogen (H), deuterium (D), and tritium (T) based on EAST plasma conditions. Results prove that H with a lighter mass has a stronger ability to penetrate into the core plasma than D and T, resulting in a higher density in the core and a lower density in the SOL. If the line-averaged electron density is selected to characterize the detachment onset, the hydrogen isotope effect is strongly dependent on the measurement chord location which determines the contribution of the core electron density to the line-averaged electron density. The modeling results can explain previous hydrogen isotope experimental results in JET. The drifts effect on hydrogen isotope distributions has also been investigated. As the drifts are taken into account, the relative difference of detachment onset at the outer target becomes larger, while it becomes smaller for the inner target. The E × B drifts show a greater impact on the T ion distribution than D and H ions.
- Open Access
- 20 January 2025
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 42
Comparative studies of tungsten erosion and edge transport under partially detached divertor condition of CFETR with neon and argon seedings
- 20 January 2025
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 42
Open AccessComparative studies of tungsten erosion and edge transport under partially detached divertor condition of CFETR with neon and argon seedings
- Open Access
- 7 December 2024
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 41
Study of deuterium reflection on tungsten material with lithium coating in EAST tokamak
- 7 December 2024
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 41
Open AccessStudy of deuterium reflection on tungsten material with lithium coating in EAST tokamak
- Open Access
- 15 October 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (12) , 126048
Modelling study of divertor W leakage for different divertor conditions with Ne seeding in EAST tokamak
Sequential SOLPS-ITER and DIVIMP simulations are carried out for tungsten (W) edge transport during neon (Ne) injection in EAST, elucidating the pathway of W impurity leakage from the divertor to the core plasma under different dissipative divertor conditions. Divertor conditions from low-recycling to detachment are generated by modulating the Ne injection rate in the SOLPS simulation. With the drift velocities incorporated in DIVIMP, W transport under the drift effect is investigated. For low-density L-mode plasma conditions with favorable B t direction, the majority of W source originates from the outer divertor target and leaks upstream through the near-SOL E× B drift reversed region at both inner and outer divertors. The E× B drift is demonstrated to have a significant effect on W leakage and the effect diminishes with the increase of Ne injection rate. Compared to the D2 injection cases, Ne injection helps to achieve a strong dissipative divertor condition at a much lower plasma density, resulting in a higher W leakage ability due to the smaller friction with the background plasma. For Ne injection cases under high-density H-mode conditions, W leaks mostly through the outer divertor region while the inner divertor is fully detached. Compared to the L-mode cases, the shorter power decay lengths in the scrap-off layer (SOL) of the H-mode cases result in smaller parallel E× B drift velocities especially in the middle and far SOL region. With the increase of the Ne injection rate, the decrease of the E× B drift in the middle SOL leads to a wider near-separatrix W leakage path. Therefore, a worse divertor W screening is expected, which is consistent with the previous published experimental observations (Ding et al 2022 Nucl. Mater. Energy 33 101250).
- 15 October 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (12) , 126048
Open AccessModelling study of divertor W leakage for different divertor conditions with Ne seeding in EAST tokamak
Sequential SOLPS-ITER and DIVIMP simulations are carried out for tungsten (W) edge transport during neon (Ne) injection in EAST, elucidating the pathway of W impurity leakage from the divertor to the core plasma under different dissipative divertor conditions. Divertor conditions from low-recycling to detachment are generated by modulating the Ne injection rate in the SOLPS simulation. With the drift velocities incorporated in DIVIMP, W transport under the drift effect is investigated. For low-density L-mode plasma conditions with favorable B t direction, the majority of W source originates from the outer divertor target and leaks upstream through the near-SOL E× B drift reversed region at both inner and outer divertors. The E× B drift is demonstrated to have a significant effect on W leakage and the effect diminishes with the increase of Ne injection rate. Compared to the D2 injection cases, Ne injection helps to achieve a strong dissipative divertor condition at a much lower plasma density, resulting in a higher W leakage ability due to the smaller friction with the background plasma. For Ne injection cases under high-density H-mode conditions, W leaks mostly through the outer divertor region while the inner divertor is fully detached. Compared to the L-mode cases, the shorter power decay lengths in the scrap-off layer (SOL) of the H-mode cases result in smaller parallel E× B drift velocities especially in the middle and far SOL region. With the increase of the Ne injection rate, the decrease of the E× B drift in the middle SOL leads to a wider near-separatrix W leakage path. Therefore, a worse divertor W screening is expected, which is consistent with the previous published experimental observations (Ding et al 2022 Nucl. Mater. Energy 33 101250).
- Open Access
- 14 August 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (10) , 106004
Simulation study of the influence of drifts on the upstream and target heat flux width under different B T directions
The heat flux width (λq ) is a key parameter determining the heat load at divertor targets. In recent years, drifts have been found to play a remarkable role in the edge plasma transport, while its influence on λq has not been well understood. Investigations of the influence of drifts on λq , systematic simulations using the SOLPS-ITER code are performed in this work. The statistics of the simulation results show that the drift under favorable/unfavorable B T tends to increase the λq in the outer/inner side and decrease the λq in the other side, which is consistent with the experiment observations. At the upstream and the target, the mechanisms of the influence of the drifts on λq are different. The upstream λq (λq ,u) is directly affected by the drift-induced convective heat flux, while λq at the target (λq ,t) is indirectly influenced through heat conduction (in the high-recycling regime) and the sheath (in the detached regime) due to the change of plasma parameters there. Furthermore, the synergetic effect of geometry and drift under favorable B T leads to an anomalously large λq ,t in the inner side at high density.
- 14 August 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (10) , 106004
Open AccessSimulation study of the influence of drifts on the upstream and target heat flux width under different B T directions
The heat flux width (λq ) is a key parameter determining the heat load at divertor targets. In recent years, drifts have been found to play a remarkable role in the edge plasma transport, while its influence on λq has not been well understood. Investigations of the influence of drifts on λq , systematic simulations using the SOLPS-ITER code are performed in this work. The statistics of the simulation results show that the drift under favorable/unfavorable B T tends to increase the λq in the outer/inner side and decrease the λq in the other side, which is consistent with the experiment observations. At the upstream and the target, the mechanisms of the influence of the drifts on λq are different. The upstream λq (λq ,u) is directly affected by the drift-induced convective heat flux, while λq at the target (λq ,t) is indirectly influenced through heat conduction (in the high-recycling regime) and the sheath (in the detached regime) due to the change of plasma parameters there. Furthermore, the synergetic effect of geometry and drift under favorable B T leads to an anomalously large λq ,t in the inner side at high density.
- Open Access
- 23 February 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (4) , 046009
Drifts effect on the divertor W leakage mechanisms under different dissipative divertor conditions of EAST
A new drift module has been developed in the DIVIMP code, enabling two-dimensional simulations of tungsten (W) transport in the edge plasma with full drifts included. By using the SOLPS-DIVIMP code package, the impact of drifts on W transport and screening has been investigated for various levels of dissipative divertor conditions and different divertor geometric configurations in EAST. Simulation results reveal that E ⃗ × B ⃗ drifts can enhance the W leakage by more than one order of magnitude. Under the favorable Bt direction, W erosion mainly occurs on the outer divertor target, making the W leakage from the outer divertor region the dominator. A leakage path from the near-scrape-off layer (SOL) region is revealed by the modeling results. In the leakage path, both the ion temperature gradient force and the reversed poloidal E ⃗ × B ⃗ drift are pointing upstream. With the radial E ⃗ × B ⃗ drift pushing W ions from the well-screened far-SOL region to the near-SOL region, the leakage from the near-SOL region becomes significant. As the divertor condition varies from the low-recycling regime to the deep detachment regime, the decrease of the ion temperature gradient velocity and poloidal E ⃗ × B ⃗ drift velocity narrows the width of the near-SOL leakage tunnel and thus enhances W screening. While under the unfavorable Bt , W erosion and leakage from the inner divertor target matters, the leakage mechanism especially the leakage path from the near-SOL region is similar as the favorable Bt cases. Furthermore, the effect of different divertor geometries on the W screening has been investigated. The configuration with the outer strike point (OSP) on the horizontal divertor plate is proved to narrow the near-SOL leakage tunnel, and thus the unreversed poloidal E ⃗ × B ⃗ drift pointing to the divertor target dominates and helps to enhance the divertor W screening. For the same D 2 puffing rate, the W leakage ability of cases with the OSP on the horizontal target can be more than 10 times weaker than the cases with the OSP on the vertical target, especially when the divertor is detached.
- 23 February 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (4) , 046009
Open AccessDrifts effect on the divertor W leakage mechanisms under different dissipative divertor conditions of EAST
A new drift module has been developed in the DIVIMP code, enabling two-dimensional simulations of tungsten (W) transport in the edge plasma with full drifts included. By using the SOLPS-DIVIMP code package, the impact of drifts on W transport and screening has been investigated for various levels of dissipative divertor conditions and different divertor geometric configurations in EAST. Simulation results reveal that E ⃗ × B ⃗ drifts can enhance the W leakage by more than one order of magnitude. Under the favorable Bt direction, W erosion mainly occurs on the outer divertor target, making the W leakage from the outer divertor region the dominator. A leakage path from the near-scrape-off layer (SOL) region is revealed by the modeling results. In the leakage path, both the ion temperature gradient force and the reversed poloidal E ⃗ × B ⃗ drift are pointing upstream. With the radial E ⃗ × B ⃗ drift pushing W ions from the well-screened far-SOL region to the near-SOL region, the leakage from the near-SOL region becomes significant. As the divertor condition varies from the low-recycling regime to the deep detachment regime, the decrease of the ion temperature gradient velocity and poloidal E ⃗ × B ⃗ drift velocity narrows the width of the near-SOL leakage tunnel and thus enhances W screening. While under the unfavorable Bt , W erosion and leakage from the inner divertor target matters, the leakage mechanism especially the leakage path from the near-SOL region is similar as the favorable Bt cases. Furthermore, the effect of different divertor geometries on the W screening has been investigated. The configuration with the outer strike point (OSP) on the horizontal divertor plate is proved to narrow the near-SOL leakage tunnel, and thus the unreversed poloidal E ⃗ × B ⃗ drift pointing to the divertor target dominates and helps to enhance the divertor W screening. For the same D 2 puffing rate, the W leakage ability of cases with the OSP on the horizontal target can be more than 10 times weaker than the cases with the OSP on the vertical target, especially when the divertor is detached.