INIoana-Theodora Nistea

Ioana-Theodora Nistea

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ioana-Theodora Nistea has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Développement des techniques optiques et acoustiques de mesure de champs orientées vers la vibroacoustique

    by Ioana Theodora Nistea

    L'utilisation des techniques de mesure optiques impose un choix, souvent difficile, entre la résolution temporelle et la résolution spatiale. L'interferométrie Speckle (IS) fournit des mesures des champs d'amplitudes de vibration de grande résolution spatiale, mais la résolution temporelle des mesures est réduite par les cadences d'acquisition des détecteurs. La thèse est dédiée au développement d'un système interférométrique adapté à la mesure des vibrations et des phénomènes dynamiques des structures, basé sur les principes de l'IS, mais ayant une résolution temporelle accrue. Le système a été testé à des cadences de plus de 26000 images/s pour les cas suivants : sollicitation harmonique mono-fréquence ou par une forme d'onde arbitraire ; sollicitation dynamique par une séquence d'échelons de force ; choc mécanique. Les essais ont démontré que le système est capable de dépasser les systèmes classiques d'IS à laser continu en ce qui concerne la mesure des phénomènes dynamiques.

  • Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

    by Ralf D. Geckeler, Andreas Just, Michael Krause, Simon G. Alcock, Murilo Bazan da Silva, Ioana-Theodora Nistea, Damon English, Simon Rochester, Valeriy V. Yashchuk

    Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. We also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.


  • A new, ultra-stable lab for nano-metrology of x-ray optics at Diamond Light Source

    by S. G. Alcock, I.-T. Nistea, M. Bazan da Silva, J. Kelly, G. Preece, A. Howell, H. Wang, K. Sawhney

    A new Optics Metrology Laboratory for assembling and characterizing beamline x-ray optical systems has been built. This replaces the old laboratory, which was demolished to make space for construction of a new flagship beamline for the forthcoming Diamond-II facility upgrade. The new cleanroom laboratory is located between several beamlines and laboratories, which intermittently generate significantly higher levels of acoustic noise and floor vibrations. A threefold design strategy was employed to create an ultra-stable environment for the sensitive, optical metrology instruments. First, the walls, ceiling and doors of the laboratory were constructed to attenuate acoustic noise. Second, the air handling systems were designed to minimize self-production of noise and vibrations. Finally, engineering solutions were developed to further isolate the metrology instruments from environmental fluctuations. Overall, despite higher levels of external disturbances, this strategy enables nano-metrology to be successfully conducted in the new laboratory. The shielded environment around each instrument achieves noise rating NR30, which is 5–25 dB quieter than the old laboratory. Over 60-h, the temperature inside the Diamond-NOM’s enclosure varied by only 0.004 °C rms, and humidity changed by <1% RH. All optical metrology instruments are now performing better than in the old laboratory: the slope error repeatability of Diamond-NOM is improved from 15 to 9 nrad rms; the GTX micro-interferometer has measured super-polished substrates with micro-roughness <40 pm rms; the new gantry for Speckle Angular Measurement is commissioned; and the HDX Fizeau interferometer has measured mirrors with slope errors <50 nrad.


  • Open Access

    Picometre-level surface control of a closed-loop, adaptive X-ray mirror with integrated real-time interferometric feedback

    by Ioana-Theodora Nistea, Simon G. Alcock, Andrew Foster, Vivek Badami, Riccardo Signorato, Matteo Fusco

    We provide a technical description and experimental results of the practical development and offline testing of an innovative, closed-loop, adaptive mirror system capable of making rapid, precise and ultra-stable changes in the size and shape of reflected X-ray beams generated at synchrotron light and free-electron laser facilities. The optical surface of a piezoelectric bimorph deformable mirror is continuously monitored at 20 kHz by an array of interferometric sensors. This matrix of height data is autonomously converted into voltage commands that are sent at 1 Hz to the piezo actuators to modify the shape of the mirror optical surface. Hence, users can rapidly switch in closed-loop between pre-calibrated X-ray wavefronts by selecting the corresponding freeform optical profile. This closed-loop monitoring is shown to repeatably bend and stabilize the low- and mid-spatial frequency components of the mirror surface to any given profile with an error <200 pm peak-to-valley, regardless of the recent history of bending and hysteresis. Without closed-loop stabilization after bending, the mirror height profile is shown to drift by hundreds of nanometres, which will slowly distort the X-ray wavefront. The metrology frame that holds the interferometric sensors is designed to be largely insensitive to temperature changes, providing an ultra-stable reference datum to enhance repeatability. We demonstrate an unprecedented level of fast and precise optical control in the X-ray domain: the profile of a macroscopic X-ray mirror of over 0.5 m in length was freely adjusted and stabilized to atomic level height resolution. Aside from demonstrating the extreme sensitivity of the interferometer sensors, this study also highlights the voltage repeatability and stability of the programmable high-voltage power supply, the accuracy of the correction-calculation algorithms and the almost instantaneous response of the bimorph mirror to command voltage pulses. Finally, we demonstrate the robustness of the system by showing that the bimorph mirror's optical surface was not damaged by more than 1 million voltage cycles, including no occurrence of the `junction effect' or weakening of piezoelectric actuator strength. Hence, this hardware combination provides a real time, hyper-precise, temperature-insensitive, closed-loop system which could benefit many optical communities, including EUV lithography, who require sub-nanometre bending control of the mirror form.


  • Open Access

    Sub-nanometre quality X-ray mirrors created using ion beam figuring

    by Arindam Majhi, Riley Shurvinton, Paresh Chandra Pradhan, Matthew Hand, Weichen Gu, Murilo Bazan Da Silva, Simone Moriconi, Ioana Nistea, Simon G. Alcock, Hongchang Wang, et al.

    Ion beam figuring (IBF) is a powerful technique for figure correction of X-ray mirrors to a high accuracy. Here, recent technical advancements in the IBF instrument developed at Diamond Light Source are presented and experimental results for figuring of X-ray mirrors are given. The IBF system is equipped with a stable DC gridded ion source (120 mm diameter), a four-axis motion stage to manipulate the optic, a Faraday cup to monitor the ion-beam current, and a camera for alignment. A novel laser speckle angular measurement instrument also provides on-board metrology. To demonstrate the IBF system's capabilities, two silicon X-ray mirrors were processed. For 1D correction, a height error of 0.08 nm r.m.s. and a slope error of 44 nrad r.m.s. were achieved. For 2D correction over a 67 mm × 17 mm clear aperture, a height error of 0.8 nm r.m.s. and a slope error of 230 nrad r.m.s. were obtained. For the 1D case, this optical quality is comparable with the highest-grade, commercially available, X-ray optics.


  • Open Access

    Ion beam figuring for X-ray mirrors: history, state-of-the-art and future prospects

    by Riley Shurvinton, Hongchang Wang, Paresh Pradhan, Ioana-Theodora Nistea, Simon Alcock, Murilo Bazan Da Silva, Arindam Majhi, Kawal Sawhney

    Synchrotron light sources require X-ray optics with extremely demanding accuracy for the surface profile, with less than 100 nrad slope errors and sub-nanometre height errors. Such errors are challenging to achieve for aspheres using traditional polishing methods. However, post-polishing error correction can be performed using techniques such as ion beam figuring (IBF) to improve optics to the desired quality. This work presents a brief overview of the history of IBF, introduces some of the challenges for obtaining such demanding figure errors, and highlights the work done at several in-house IBF facilities at synchrotron light sources worldwide to obtain state-of-the-art optical quality.


  • Open Access

    I21: an advanced high-resolution resonant inelastic X-ray scattering beamline at Diamond Light Source

    by Ke-Jin Zhou, Andrew Walters, Mirian Garcia-Fernandez, Thomas Rice, Matthew Hand, Abhishek Nag, Jiemin Li, Stefano Agrestini, Peter Garland, Hongchang Wang, et al.

    The I21 beamline at Diamond Light Source is dedicated to advanced resonant inelastic X-ray scattering (RIXS) for probing charge, orbital, spin and lattice excitations in materials across condensed matter physics, applied sciences and chemistry. Both the beamline and the RIXS spectrometer employ divergent variable-line-spacing gratings covering a broad energy range of 280–3000 eV. A combined energy resolution of ∼35 meV (16 meV) is readily achieved at 930 eV (530 eV) owing to the optimized optics and the mechanics. Considerable efforts have been paid to the design of the entire beamline, particularly the implementation of the collection mirrors, to maximize the X-ray photon throughput. The continuous rotation of the spectrometer over 150° under ultra high vacuum and a cryogenic manipulator with six degrees of freedom allow accurate mappings of low-energy excitations from solid state materials in momentum space. Most importantly, the facility features a unique combination of the high energy resolution and the high photon throughput vital for advanced RIXS applications. Together with its stability and user friendliness, I21 has become one of the most sought after RIXS beamlines in the world.


  • Open Access

    Dynamic adaptive X-ray optics. Part I. Time-resolved optical metrology investigation of the bending behaviour of piezoelectric bimorph deformable X-ray mirrors

    by Simon G. Alcock, Ioana-Theodora Nistea, Riccardo Signorato, Kawal Sawhney

    Piezoelectric bimorph deformable mirrors (`bimorphs') are routinely used on many synchrotron and free-electron laser beamlines to provide active variation in the size and shape of the X-ray beam. However, the time-domain potential of such optics has never been fully exploited. For the first time, the fast dynamic bending response of bimorphs is investigated here using Fizeau interferometry. Automated scripts for acquisition and analysis were developed to collect Fizeau data at a rate of 0.1 Hz to record dynamic changes in the optical surface as voltages were applied to the electrodes of the piezoelectric actuators. It is demonstrated that residual drift in the tangential radius of curvature of a bimorph can be significantly reduced using enhanced opto-mechanical holders and a fast programmable high-voltage power supply. Further improvements are achieved by applying small opposing voltages to compensate for piezoelectric creep. The present study shows that bimorphs can truly be used as high-speed adaptive optics for the X-ray domain, even without closed-loop feedback correction. This opens the possibility for relatively simple real-time tuning of the profile of X-ray bimorphs. Part II of this study [Alcock, Nistea, Signorato, Owen, Axford, Sutter, Foster & Sawhney (2019), J. Synchrotron Rad. 26, 45–51] builds upon these results and demonstrates how bimorphs can rapidly provide customisable sizes and shapes of synchrotron X-ray beams, specifically tailored to suit the experimental samples being investigated.


  • Open Access

    Dynamic adaptive X-ray optics. Part II. High-speed piezoelectric bimorph deformable Kirkpatrick–Baez mirrors for rapid variation of the 2D size and shape of X-ray beams

    by Simon G. Alcock, Ioana-Theodora Nistea, Riccardo Signorato, Robin L. Owen, Daniel Axford, John P. Sutter, Andrew Foster, Kawal Sawhney

    The tangential curvature of actively bent X-ray mirrors at synchrotron radiation and X-ray free-electron laser (XFEL) facilities is typically only changed every few hours or even days. This operation can take tens of minutes for active optics with multiple bending actuators and often requires expert guidance using in situ monitoring devices. Hence, the dynamic performance of active X-ray optics for synchrotron beamlines has historically not been exploited. This is in stark contrast to many other scientific fields. However, many areas of synchrotron radiation and XFEL science, including macromolecular crystallography, could greatly benefit from the ability to change the size and shape of the X-ray beam rapidly and continuously. The advantages of this innovative approach are twofold: a large reduction in the dead time required to change the size of the X-ray beam for different-sized samples and the possibility of making multiple changes to the beam during the measurement of a single sample. In the preceding paper [Part I; Alcock, Nistea, Signorato & Sawhney (2019), J. Synchrotron Rad. 26, 36–44], which accompanies this article, high-speed visible-light Fizeau interferometry was used to identify the factors which influence the dynamic bending behaviour of piezoelectric bimorph deformable X-ray mirrors. Building upon this ex situ metrology study, provided here is the first synchrotron radiation beamline implementation of high-speed adaptive X-ray optics using two bimorphs operating as a Kirkpatrick–Baez pair. With optimized substrates, novel opto-mechanical holders and a next-generation high-voltage power supply, the size of an X-ray beam was rapidly and repeatedly switched in <10 s. Of equal importance, it is also shown that compensation of piezoelectric creep ensures that the X-ray beam size remains stable for more than 1 h after making a major change. The era of high-speed adaptive X-ray optics for synchrotron radiation and XFEL beamlines has begun.


  • Open Access

    Long, elliptically bent, active X-ray mirrors with slope errors <200 nrad

    by Ioana T. Nistea, Simon G. Alcock, Paw Kristiansen, Adam Young

    Actively bent X-ray mirrors are important components of many synchrotron and X-ray free-electron laser beamlines. A high-quality optical surface and good bending performance are essential to ensure that the X-ray beam is accurately focused. Two elliptically bent X-ray mirror systems from FMB Oxford were characterized in the optical metrology laboratory at Diamond Light Source. A comparison of Diamond-NOM slope profilometry and finite-element analysis is presented to investigate how the 900 mm-long mirrors sag under gravity, and how this deformation can be adequately compensated using a single, spring-loaded compensator. It is shown that two independent mechanical actuators can accurately bend the trapezoidal substrates to a range of elliptical profiles. State-of-the-art residual slope errors of R/R = 0.085% and 0.156% r.m.s. for the two bending directions) and stability over 24 h (ΔR/R = 0.07% r.m.s.) provide reliable beamline performance.