MSMurilo Bazan da Silva

Murilo Bazan da Silva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Murilo Bazan da Silva has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    3rd generation, UHV bakeable, bimorph deformable X-ray mirror with slope errors < 50 nanoradians for a range of elliptical profiles

    by Simon G. Alcock, Murilo Bazan da Silva, Riley Shurvinton, Elliot Jane, Will Jones, Douglas Smith, Hiroki Nakamori, Kawal Sawhney

    A new class of 3rd generation, bimorph deformable, X-ray mirrors have been developed, which are UHV “bakeable” to 200°C and provide diffraction-limited performance for achromatic focusing and wavefront correction of high-intensity photon beams. Optical metrology was used to reduce slope errors to ∼ 42 nrad rms and height errors to ∼ 200 pm rms for concave, flat, and convex elliptical curvatures. Curved X-ray mirrors with slope errors < 50 nrad rms and height errors < 500 pm rms are required for nano-focusing and coherence applications at low-emittance synchrotron light and free electron laser facilities. In recent years, impressive technical progress has been made to fabricate fixed-curvature X-ray mirrors, approaching diffraction-limited performance. However, for many scientific applications, active optics with a deformable surface profile are required to intermittently change the focal distance or size of the X-ray beam, or to make fine adjustments to the X-ray wavefront. What we believe to be a new class of high-grade, actively deformable optics have been developed, which provide diffraction-limited performance for achromatic focusing and wavefront correction of X-ray beams. 3rd generation, bimorph deformable, X-ray mirrors have piezoelectric PZT actuators bonded to the silicon substrate using silver nano-particles. They can be safely thermally annealed to 200°C and are ultra-high vacuum compatible, making them suitable for a wide range of X-ray energies, including soft X-rays. We present a comprehensive optical metrology study of a 32-channel, 3rd generation bimorph mirror mounted in an opto-mechanical holder to assess suitability for routine beamline operation. Fizeau interferometry and slope profilometry were performed to characterize the range, drift, stability, repeatability, and resolution of bending. Voltages to individual electrodes were optimized to minimise surface errors, based on metrology feedback and a constrained, linear algebra solver. Slope errors of ∼ 42 nrad rms and height errors ∼ 200 pm rms were achieved for three different curvatures (concave, flat, and convex). Metrology testing also demonstrated the extreme resolution of bending (2 nm changes in the height profile by incrementally applying 0.1 V shifts to all piezo actuators) and long-term curvature stability of 0.1% rms over 16 hours. Hysteresis, creep, and short-term drift of the bimorph’s profile were observed, which will be the subject of future research.


  • Ion beam shaping and figuring of X-ray sub-microfocusing mirrors

    by Riley Shurvinton, Paresh Pradhan, Murilo Bazan da Silva, Vishal Dhamgaye, Dongni Zhang, Hongchang Wang, Kawal Sawhney

    High-performance synchrotron X-ray focusing mirrors require aspheric surfaces with nanoradian slope accuracy, which are challenging to provide for many manufacturers. Conventional grinding and polishing techniques typically introduce tooling marks to the surface during the fabrication process, and these marks can impose significant challenges for the deterministic figuring processes used as the final step in mirror fabrication, ultimately limiting the slope errors of the mirrors. To overcome this limitation, we present an alternative approach by using ion beam shaping to form an elliptical sub-microfocusing mirror from a flat mirror, followed by ion beam figuring to improve the remaining errors. Two mirrors fabricated using this approach achieved tangential slope errors below 200 nrad root mean squared (rms), in contrast to a conventionally pre-shaped mirror with identical ellipse parameters that was limited to > 500 nrad rms after ion beam figuring due to residual tooling marks. In X-ray focusing tests, the ion beam shaped mirrors are able to realise a spot size below 250 nm (full width half maximum), compared to 404 nm for the pre-shaped mirror. This demonstrates the excellent potential of ion beam shaping as a method for rapid, efficient and high-quality X-ray mirror fabrication.


  • Application and performance of the novel Elcomat 5000 autocollimator in slope-measuring profilometry of beamline optics

    by Ralf D. Geckeler, Andreas Just, Michael Krause, Simon G. Alcock, Murilo Bazan da Silva, Ioana-Theodora Nistea, Damon English, Simon Rochester, Valeriy V. Yashchuk

    Autocollimators are used in profilometers for the precise form measurement of beam-shaping optics for synchrotron light sources and x-ray free-electron lasers. This application requires using an aperture stop, typically 2.5 mm in diameter, which limits the footprint of the autocollimator’s measuring beam on the optics to achieve a sufficiently high lateral resolution. Central to the development of profilometry has been the availability of commercial autocollimators, such as the Elcomat 3000 from Möller–Wedel Optical. Although autocollimators are generally not designed for use with small apertures, this device has proven capable and has become the de facto standard. Now that it has been replaced by the Elcomat 5000, we evaluate the performance of several autocollimators of this type at small apertures, including the characterization of instrument transfer functions with a chirped height profile. We demonstrate that the Elcomat 5000 is capable of repeatable angle measurements with a standard deviation of 0.014 arcsec at an aperture diameter of 1.6 mm, whereas the Elcomat 3000 achieves 0.03 arcsec at 2.5 mm, comparing models with modified reticle designs. We also investigate the influence of optical aberrations of the autocollimator’s objective and their changes with the path length to the surface under test. We characterize the sensitivity of the angle measurement to changes in environmental parameters, in particular, barometric pressure. These efforts are aimed at approaching fundamental limits in the characterization of the shape of optical surfaces with autocollimator-based profilometers so that these are ready for characterizing the next generation of synchrotron and XFEL beamline optics.

  • A new, ultra-stable lab for nano-metrology of x-ray optics at Diamond Light Source

    by S. G. Alcock, I.-T. Nistea, M. Bazan da Silva, J. Kelly, G. Preece, A. Howell, H. Wang, K. Sawhney

    A new Optics Metrology Laboratory for assembling and characterizing beamline x-ray optical systems has been built. This replaces the old laboratory, which was demolished to make space for construction of a new flagship beamline for the forthcoming Diamond-II facility upgrade. The new cleanroom laboratory is located between several beamlines and laboratories, which intermittently generate significantly higher levels of acoustic noise and floor vibrations. A threefold design strategy was employed to create an ultra-stable environment for the sensitive, optical metrology instruments. First, the walls, ceiling and doors of the laboratory were constructed to attenuate acoustic noise. Second, the air handling systems were designed to minimize self-production of noise and vibrations. Finally, engineering solutions were developed to further isolate the metrology instruments from environmental fluctuations. Overall, despite higher levels of external disturbances, this strategy enables nano-metrology to be successfully conducted in the new laboratory. The shielded environment around each instrument achieves noise rating NR30, which is 5–25 dB quieter than the old laboratory. Over 60-h, the temperature inside the Diamond-NOM’s enclosure varied by only 0.004 °C rms, and humidity changed by <1% RH. All optical metrology instruments are now performing better than in the old laboratory: the slope error repeatability of Diamond-NOM is improved from 15 to 9 nrad rms; the GTX micro-interferometer has measured super-polished substrates with micro-roughness <40 pm rms; the new gantry for Speckle Angular Measurement is commissioned; and the HDX Fizeau interferometer has measured mirrors with slope errors <50 nrad.


  • Development of multilayer monochromators for stripe-free X-ray imaging

    by Riley Shurvinton, Paresh Pradhan, Murilo Bazan Da Silva, Wadwan Singhapong, Wai Jue Tan, Arindam Majhi, Vishal Dhamgaye, Hongchang Wang, Kawal Sawhney

    Multilayer (ML) monochromators are essential components in synchrotron radiation facilities, widely used for X-ray imaging and X-ray diffraction, as well as select X-ray spectroscopy techniques. However, ML monochromators introduce stripe artefacts to the reflected beam, which degrade the quality of the X-ray images. These stripe artefacts originate from figure errors on the monochromator’s surface, which are challenging to minimise for most manufacturers. In this study, we demonstrate stripe-free imaging from ultra-high-quality ML monochromators. We employed a state-of-the-art ion beam figuring (IBF) technique to produce multilayer substrates with a cutting-edge slope error of less than 30 nrad root mean squared (rms). These substrates were coated in an advanced multilayer deposition system, enabling the production of uniform multilayer coatings. The performance of the ML monochromators was tested at the B16 test beamline at the diamond light source. Speckle-based metrology was used to verify the theoretical link between wavefront curvature and the appearance of stripe artefacts. We obtained stripe-free X-ray images from the newly fabricated ML monochromators in both single-bounce and double-bounce configurations, with excellent image clarity and flat field uniformity. This represents a breakthrough in the production of ML monochromators.


  • Improving the quality of x-ray mirrors: An inter-lab, optical metrology collaboration to guide deterministic polishing

    by Simon G. Alcock, Ioana-Theodora Nistea, Murilo Bazan da Silva, Kawal Sawhney, Norman Niewrzella, Holger Lasser, Amparo Vivo, Ray Barrett, Jana Buchheim, Grzegorz Gwalt, et al.

    The surface quality of x-ray mirrors is a major constraint on optical performance at synchrotron light and free electron laser facilities. A limiting factor for creating state-of-the-art optics is the accuracy of metrology data to deterministically guide the polishing tool to correct surface errors. The “MooNpics” (Metrology On One-Nanometer-Precise Optics) collaboration aims to improve optical metrology capabilities at European facilities to enable reproducible measurement of long or curved optics with height errors <1 nm rms and slope errors 100 km); an ellipse with added parabolic arcs; and a strongly curved sphere (R ∼ 9.3 m) with an added spatially varying chirp. This study highlighted calibration issues with several instruments, which were subsequently corrected. In this paper, we present results about the ellipse mirror. Based on metrology data provided by the collaboration, two cycles of ion beam figuring improved all aspects of the mirror, including correcting the ellipse parameters, reducing high- and mid-frequency spatial polishing errors, and refining the shape of the parabolic arcs. Overall, the slope and height errors were improved by a factor of ∼10. We also show how the round-robin measurement exercise helped refine “best practice” procedures for mounting optics, alignment, and data acquisition and analysis methods. It is hoped that this collaborative project will ignite further improvements in the production quality of x-ray optics to benefit many scientific communities around the world.


  • Open Access

    An automated and robust method for modelling X-ray beamlines with plane grating monochromators

    by Patrick Yuheng Wang, Murilo Bazan da Silva, Georg Held, Hongchang Wang, Kawal Sawhney, Andrew C. Walters

    The plane grating monochromator (PGM) is an optical instrument used in the majority of soft X-ray beamlines. Despite its ubiquity, the PGM efficiency can easily be overestimated, because the geometry of many modern PGMs can lead to unexpected blocking of the beam. We have developed a new workflow in Python for simulating PGMs, thus extending the capabilities of SHADOW3, a well established ray tracing software tool. We have used our method to simulate the flux on branch C of the Versatile Soft X-ray (VerSoX) beamline B07 at Diamond Light Source. The simulation results demonstrate qualitative agreement with the experimental measurements, confirming the robustness of the proposed methodology.

  • Open Access

    PGMweb: an online tool for visualizing the X-ray beam path through plane grating monochromators

    by Patrick Yuheng Wang, Murilo Bazan da Silva, Matthew Hand, Hongchang Wang, Peter Chang, Victoria Beilsten-Edmands, Timur K. Kim, Tien-Lin Lee, Kawal Sawhney, Andrew C. Walters

    We present here a newly developed software tool (called PGMweb) for computing and simulating the X-ray beam path through a plane grating monochromator (PGM), a key component in soft X-ray beamlines at modern synchrotron and free-electron laser facilities. A historical overview of the development of PGMs is presented, with special attention dedicated to the collimated PGM optical scheme found at several X-ray facilities worldwide. The analytical expressions that fully describe the geometry of a PGM are derived and have been implemented as functions in a Python library (pyplanemono). PGMweb is distributed as a web-based application that can be run in any modern browser without installation, making its use very straightforward for X-ray beamline designers and beamline scientists alike.


  • Open Access

    Ion beam figuring for X-ray mirrors: history, state-of-the-art and future prospects

    by Riley Shurvinton, Hongchang Wang, Paresh Pradhan, Ioana-Theodora Nistea, Simon Alcock, Murilo Bazan Da Silva, Arindam Majhi, Kawal Sawhney

    Synchrotron light sources require X-ray optics with extremely demanding accuracy for the surface profile, with less than 100 nrad slope errors and sub-nanometre height errors. Such errors are challenging to achieve for aspheres using traditional polishing methods. However, post-polishing error correction can be performed using techniques such as ion beam figuring (IBF) to improve optics to the desired quality. This work presents a brief overview of the history of IBF, introduces some of the challenges for obtaining such demanding figure errors, and highlights the work done at several in-house IBF facilities at synchrotron light sources worldwide to obtain state-of-the-art optical quality.


  • Open Access

    Correcting retrace and system imaging errors to achieve nanometer accuracy in full aperture, single-shot Fizeau interferometry

    by Katherine Morrow, Murilo Bazan da Silva, Simon Alcock

    X-ray mirrors with single-digit nanometer height errors are required to preserve the quality of ultra-intense photon beams produced at synchrotron or free electron laser sources. To fabricate suitable X-ray mirrors, accurate metrology data is needed for deterministic polishing machines. Fizeau phase-shifting interferometers are optimized to achieve accurate results under nulled conditions. However, for curved or aspheric mirrors, a limited choice of reference optic often necessitates measurement under non-nulled conditions, which can introduce retrace error. Using experimental measurements of a multi-tilted calibration mirror, we have developed an empirical model of Fizeau retrace error, based on Zernike polynomial fitting. We demonstrate that the model is in good agreement with measurements of ultra-high quality, weakly-curved X-ray mirrors with sags of only a few tens of microns. Removing the predicted retrace error improves the measurement accuracy for full aperture, single shot, Fizeau interferometry to < 2 nm RMS.