DCDavid M. J. Cowell

David M. J. Cowell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David M. J. Cowell has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Toward using the Villari effect for non-destructive evaluation of steel structures

    by C. A. Ives, S. G. H. Staples, C. K. Vo, D. M. J. Cowell, S. Freear, B. T. H. Varcoe

    This work follows on from studies carried out by Jiles and Atherton on magnetic hysteresis and on the magnetomechanical effect. The Jiles–Atherton equation, which models the rate of change of magnetization with respect to stress, was solved numerically in the forward and reverse directions for stress up to 90 MPa, suggesting that stressing carbon steel will cause a lasting change in the magnetization of the sample. This was confirmed experimentally by measuring the B-field in proximity to samples of C45 steel while undergoing tensile stress, with the pattern of magnetization suggesting that the magnetic domains reorient themselves in the geomagnetic field when stressing loosens their pinning. A further experiment on two samples confirms this, with the B-field around the samples showing strong changes according to their orientation in the geomagnetic field at the time of the stressing. This work has relevance to the non-destructive testing of steel structures such as pipelines, and the relevance of the experiments to this work is considered, as well as future prospects.


  • Integrated Hybrid Sub-Aperture Beamforming and Time-Division Multiplexing for Massive Readout in Ultrasound Imaging

    by Ahmad Rezvanitabar, Gwangrok Jung, Coskun Tekes, Thomas M. Carpenter, David M. J. Cowell, Steven Freear, F. Levent Degertekin

    This paper demonstrates hybrid sub-aperture beamforming (SAB) with time-division multiplexing (TDM) for massive interconnect reduction in ultrasound imaging systems. A single-chip front-end system prototype has been fabricated in 180-nm HV BCD technology that combines 5×1 SAB with 8×1 TDM to efficiently reduce the number of receive signal interconnects by a factor of 40. The system includes on-chip high-voltage (HV) pulsers capable of generating unipolar pulses up to 70 V in transmit (TX) mode. The receiver (RX) chain consists of a T/R switch, a variable-gain low-noise amplifier (VG-LNA) with 4-step gain control (15-32 dB) for time-gain compensation followed by a programmable switched-capacitor analog delay-and-sum beamformer. The proof-of-concept prototype operates at a 200-MHz clock frequency and the SAB provides 32-step fine delays with a maximum delay of 310 ns corresponding to better than $\lambda$ /20 delay quantization at 5 MHz. With these specifications, the SAB is capable of beam steering from 0 $^{\circ }$ to 45 $^{\circ }$ for a 5-element subarray with 150-micron pitch ( $\lambda$ /2), providing a near-ideal phased array imaging performance. The sub-aperture beamformer is followed by the TDM system where each of the 8 channels is sampled at a rate of 25 MS/s after an anti-aliasing bandpass filter. The full functionality of the prototype chip is validated through electrical and acoustic measurements on a 1-D capacitive micromachined ultrasonic transducer (CMUT) array designed for intracardiac echocardiography (ICE).


  • Open Access

    An Open Access Chamber Designed for the Acoustic Characterisation of Microbubbles

    by Elliott Smith, Luzhen Nie, James McLaughlan, Harry Clegg, Thomas Carpenter, David Cowell, Stephen Evans, Alejandro F. Frangi, Steven Freear

    Microbubbles are used as contrast agents in clinical ultrasound for Left Ventricular Opacification (LVO) and perfusion imaging. They are also the subject of promising research in therapeutics as a drug delivery mechanism or for sonoporation and co-administration. For maximum efficacy in these applications, it is important to understand the acoustic characteristics of the administered microbubbles. Despite this, there is significant variation in the experimental procedures and equipment used to measure the acoustic properties of microbubble populations. A chamber was designed to facilitate acoustic characterisation experiments and was manufactured using additive manufacturing techniques. The design has been released to allow wider uptake in the research community. The efficacy of the chamber for acoustic characterisation has been explored with an experiment to measure the scattering of SonoVue® microbubbles at the fundamental frequency and second harmonic under interrogation from emissions in the frequency range of 1.6 to 6.4 MHz. The highest overall scattering values were measured at 1.6 MHz and decreased as the frequency increased, a result which is in agreement with previously published measurements. Statistical analysis of the acoustic scattering measurements have been performed and a significant difference, at the 5% significance level, was found between the samples containing contrast agent and the control sample containing only deionised water. These findings validate the proposed design for measuring the acoustic scattering characteristics of ultrasound contrast agents.


  • High-Power Gallium Nitride HIFU Transmitter With Integrated Real-Time Current and Voltage Measurement

    by Thomas M. Carpenter, David M. J. Cowell, Harry R. Clegg, James R. McLaughlan, Steven Freear

    High-Intensity Focused Ultrasound (HIFU) therapy provides a non-invasive technique with which to destroy cancerous tissue without using ionizing radiation. To drive large single-element High-Intensity Focused Ultrasound (HIFU) transducers, ultrasound transmitters capable of delivering high powers at relevant frequencies are required. The acoustic power delivered to a transducers focal region will determine the treated area, and due to safety concerns and intervening layers of attenuation, control of this output power is critical. A typical setup involves large inefficient linear power amplifiers to drive the transducer. Switched mode transmitters allow for a more compact drive system with higher efficiencies, with multi-level transmitters allowing control over the output power. Real-time monitoring of power delivered can avoid damage to the transducer and injury to patients due to over treatment, and allow for precise control over the output power. This study demonstrates a transformer-less, high power, switched mode transmit transmitter based on Gallium-Nitride (GaN) transistors that is capable of delivering peak powers up to 1.8 kW at up to 600 Vpp, while operating at frequencies from DC to 5 MHz. The design includes a 12 b 16 MHz floating Current/Voltage (IV) measurement circuit to allow real-time high-side monitoring of the power delivered to the transducer allowing use with multi-element transducers.


  • Open Access

    Motion Compensation for High-Frame-Rate Contrast-Enhanced Echocardiography Using Diverging Waves: Image Registration Versus Correlation-Based Method

    by Luzhen Nie, David M. J. Cowell, Thomas M. Carpenter, James R. McLaughlan, Arzu A. Cubukcu, Steven Freear

    By using diverging ultrasound waves, a B-mode image can be reconstructed from a single transmission with parallel beamforming. For echocardiography, this approach can provide a frame rate up to 5 kHz, which is two orders of magnitude faster than the most clinical scanners. However, image degradation arising from the lack of transmit focusing when using diverging waves, could not be alleviated by coherent compounding due to the effect of cardiac motion. The motion effects on high-frame-rate contrast-enhanced echocardiography (HFR CEE) when combining diverging waves and microbubble contrast agents were demonstrated in recent studies, with a two-stage correlation-based method and an image registration-based method proposed to enable coherent compounding. The current study compared these two methods for motion compensation in HFR CEE both in vitro and in vivo. For in vitro experiments with a rotating disk phantom, the correlation-based method improved the contrast ratio and contrast-to-noise-ratio by 5 dB and 3 dB, respectively. For the in vivo measurement, the correlation-based method provided a 6-dB improvement in contrast-to-tissue ratio.


  • Open Access

    A New Nonlinear Compounding Technique for Ultrasound B-mode Medical Imaging

    by Asraf Mohamed Moubark, Luzhen Nie, David M. J Cowell, Sawal Hamid Md Ali, Steven Freear

    Compounding techniques have been used in ultra-fast ultrasound imaging to improve image quality by reducing clutter noise, smoothing speckle variance and enhancing its spatial resolution at the cost of reducing frame rate. However, the reduction of clutter noise and side lobes inside the anechoic regions is minimal when combining conventional spatial compounding and delay-and-sum (DAS) beamforming. Despite the availability of advanced beamforming algorithms such as filtered-delay-multiply-and-sum (FDMAS), its prevalence is hindered by relatively high computational cost. In this study, a new nonlinear compounding technique known as filtered multiply and sum (FMAS) was proposed to improve the B-mode image quality without increasing the overall computational complexity. With three compunding angles, the lateral resolution for DAS-FMAS was improved by 36% and 19% compared to DAS and FDMAS. The proposed DAS-FMAS technique also provided improvements of 14.1 dB and 7.29 dB in contrast ratio than DAS and FDMAS.


  • Open Access

    Gallium Nitride Based High-Power Switched HIFU Pulser with Real-Time Current/Voltage Monitoring

    by Thomas M. Carpenter, David M. J. Cowell, Harry R. Clegg, James McLaughlan, Steven Freear

    High-Intensity Focussed Ultrasound (HIFU) techniques make use of ultrasound transducers capable of delivering high powers to be delivered at high frequencies. Real-time monitoring of power delivered can avoid damage to the transducer and injury to patients due to overexposure.This paper demonstrates the real-time current and voltage monitoring capabilities of a new Gallium-Nitride (GaN) based switched mode transmit pulser developed for the University of Leeds High-Intensity Focussed Ultrasound Array Research Platform (HIFUARP) system, which uses a novel approach of using an Analog Front End (AFE) floating on the transmitter output to provide high bandwidth current measurement.


  • Open Access

    High-Frame-Rate Contrast-Enhanced Echocardiography Using Diverging Waves: 2-D Motion Estimation and Compensation

    by Luzhen Nie, David M. J. Cowell, Thomas M. Carpenter, James R. Mclaughlan, Arzu A. Cubukcu, Steven Freear

    Combining diverging ultrasound waves and microbubbles could improve contrast-enhanced echocardiography (CEE), by providing enhanced temporal resolution for cardiac function assessment over a large imaging field of view. However, current image formation techniques using coherent summation of echoes from multiple steered diverging waves (DWs) are susceptible to tissue and microbubble motion artifacts, resulting in poor image quality. In this study, we used correlation-based 2-D motion estimation to perform motion compensation for CEE using DWs. The accuracy of this motion estimation method was evaluated with Field II simulations. The root-mean-square velocity errors were 5.9% ± 0.2% and 19.5% ± 0.4% in the axial and lateral directions, when normalized to the maximum value of 62.8 cm/s which is comparable to the highest speed of blood flow in the left ventricle (LV). The effects of this method on image contrast ratio (CR) and contrast-to-noise ratio (CNR) were tested in vitro using a tissue mimicking rotating disk with a diameter of 10 cm. Compared against the control without motion compensation, a mean increase of 12 dB in CR and 7 dB in CNR were demonstrated when using this motion compensation method. The motion correction algorithm was tested in vivo on a CEE data set acquired with the Ultrasound Array Research Platform II performing coherent DW imaging. Improvement of the B-mode and contrast-mode image quality with cardiac motion and blood flow-induced microbubble motion was achieved. The results of motion estimation were further processed to interpret blood flow in the LV. This allowed for a triplex cardiac imaging technique, consisting of B mode, contrast mode, and 2-D vector flow imaging with a high frame rate of 250 Hz.


  • Open Access

    HIFU Drive System Miniaturization Using Harmonic Reduced Pulsewidth Modulation

    by Chris Adams, Thomas M. Carpenter, David Cowell, Steven Freear, James R. McLaughlan

    Switched excitation has the potential to improve on the cost, efficiency, and size of the linear amplifier circuitry currently used in high-intensity focused ultrasound (HIFU) systems. Existing switching schemes are impaired by high harmonic distortion or lack array apodisation capability, so require adjustable supplies and/or large power filters to be useful. A multilevel pulsewidth modulation (PWM) topology could address both of these issues but the switching-speed limitations of transistors mean that there are a limited number of pulses available in each waveform cycle. In this study, harmonic reduction PWM (HRPWM) is proposed as an algorithmic solution to the design of switched waveforms. Its appropriateness for HIFU was assessed by design of a high power five-level unfiltered amplifier and subsequent thermal-only lesioning of ex vivo chicken breast. Three switched waveforms of different electrical powers (16, 26, 35 W) were generated using the HRPWM algorithm. Lesion sizes were measured and compared with those made at the same electrical power using a linear amplifier and bi-level excitation. HRPWM produced symmetric, thermal-only lesions that were the same size as their linear amplifier equivalents (p > 0.05). At 16 W, bi-level excitation produced smaller lesions but at higher power levels large transients in the acoustic waveform nucleated undesired cavitation. These results demonstrate that HRPWM can minimize HIFU drive circuity size without the need for filters to remove harmonics or adjustable power supplies to achieve array apodisation.


  • In-situ measurement of transducer impedance using AFE active termination through analysis of ultrasound echoes

    by David Cowell, Thomas Carpenter, Benjamin Fisher, Steven Freear

    Measurement of transducer impedance in ultrasound systems indicates both the performance of a transducer and the presence of damaged elements and cables. Load impedance analysis is typically performed with dedicated test equipment and is a time consuming and thus expensive process, especially for high channel count systems. This paper proposes a method for the measurement of channel source impedance (transducer, coaxial cable and T/R switch) through the use of an integrated receiver analogue front end with configurable termination resistance. The proposed method is first demonstrated using a pitch-catch configuration using a separate source transducer to excite the transducer under test. Subsequently the method is demonstrated the Ultrasound Array Research Platform (UARP) and a linear array transducer in a pulse echo mode where the transducer impedance is determined through the analysis of two ultrasound echoes. The proposed method is especially suited to rapid transducer testing in the field, such as in a hospital, or where access to the transducer is not possible as in many industrial processes.