Thomas M. Carpenter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas M. Carpenter has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Steven Freear
University of Leeds
11 shared publications - James Ross McLaughlan
School of Electronic & Electrical Engineering, University of Leeds, LS2 9JT, UK
8 shared publications - David M. J. Cowell
School of Electron. Eng., Univ. of Leeds, Leeds LS2 9JT, United Kingdom
7 shared publications - Luzhen Nie
School of Electronic and Electrical Engineering, University of Leeds, Leeds LS2 9JT, UK
4 shared publications - Chris Adams
Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON, Canada
3 shared publications - Harry R. Clegg
School of Electronic and Electrical Engineering, University of Leeds, Leeds LS2 9JT, UK
3 shared publications
Latest Publications
- Open Access
- 24 June 2026
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 181
Noninvasive pressure difference mapping by integrating ultrasonic vector flow imaging and physics-informed conditional variational learning
- 24 June 2026
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 181
Open AccessNoninvasive pressure difference mapping by integrating ultrasonic vector flow imaging and physics-informed conditional variational learning
- 8 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (5) , 972-980
Integrated Hybrid Sub-Aperture Beamforming and Time-Division Multiplexing for Massive Readout in Ultrasound Imaging
This paper demonstrates hybrid sub-aperture beamforming (SAB) with time-division multiplexing (TDM) for massive interconnect reduction in ultrasound imaging systems. A single-chip front-end system prototype has been fabricated in 180-nm HV BCD technology that combines 5×1 SAB with 8×1 TDM to efficiently reduce the number of receive signal interconnects by a factor of 40. The system includes on-chip high-voltage (HV) pulsers capable of generating unipolar pulses up to 70 V in transmit (TX) mode. The receiver (RX) chain consists of a T/R switch, a variable-gain low-noise amplifier (VG-LNA) with 4-step gain control (15-32 dB) for time-gain compensation followed by a programmable switched-capacitor analog delay-and-sum beamformer. The proof-of-concept prototype operates at a 200-MHz clock frequency and the SAB provides 32-step fine delays with a maximum delay of 310 ns corresponding to better than $\lambda$ /20 delay quantization at 5 MHz. With these specifications, the SAB is capable of beam steering from 0 $^{\circ }$ to 45 $^{\circ }$ for a 5-element subarray with 150-micron pitch ( $\lambda$ /2), providing a near-ideal phased array imaging performance. The sub-aperture beamformer is followed by the TDM system where each of the 8 channels is sampled at a rate of 25 MS/s after an anti-aliasing bandpass filter. The full functionality of the prototype chip is validated through electrical and acoustic measurements on a 1-D capacitive micromachined ultrasonic transducer (CMUT) array designed for intracardiac echocardiography (ICE).
- 8 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (5) , 972-980
Integrated Hybrid Sub-Aperture Beamforming and Time-Division Multiplexing for Massive Readout in Ultrasound Imaging
This paper demonstrates hybrid sub-aperture beamforming (SAB) with time-division multiplexing (TDM) for massive interconnect reduction in ultrasound imaging systems. A single-chip front-end system prototype has been fabricated in 180-nm HV BCD technology that combines 5×1 SAB with 8×1 TDM to efficiently reduce the number of receive signal interconnects by a factor of 40. The system includes on-chip high-voltage (HV) pulsers capable of generating unipolar pulses up to 70 V in transmit (TX) mode. The receiver (RX) chain consists of a T/R switch, a variable-gain low-noise amplifier (VG-LNA) with 4-step gain control (15-32 dB) for time-gain compensation followed by a programmable switched-capacitor analog delay-and-sum beamformer. The proof-of-concept prototype operates at a 200-MHz clock frequency and the SAB provides 32-step fine delays with a maximum delay of 310 ns corresponding to better than $\lambda$ /20 delay quantization at 5 MHz. With these specifications, the SAB is capable of beam steering from 0 $^{\circ }$ to 45 $^{\circ }$ for a 5-element subarray with 150-micron pitch ( $\lambda$ /2), providing a near-ideal phased array imaging performance. The sub-aperture beamformer is followed by the TDM system where each of the 8 channels is sampled at a rate of 25 MS/s after an anti-aliasing bandpass filter. The full functionality of the prototype chip is validated through electrical and acoustic measurements on a 1-D capacitive micromachined ultrasonic transducer (CMUT) array designed for intracardiac echocardiography (ICE).
- Open Access
- 10 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (4) , 1818
An Open Access Chamber Designed for the Acoustic Characterisation of Microbubbles
Microbubbles are used as contrast agents in clinical ultrasound for Left Ventricular Opacification (LVO) and perfusion imaging. They are also the subject of promising research in therapeutics as a drug delivery mechanism or for sonoporation and co-administration. For maximum efficacy in these applications, it is important to understand the acoustic characteristics of the administered microbubbles. Despite this, there is significant variation in the experimental procedures and equipment used to measure the acoustic properties of microbubble populations. A chamber was designed to facilitate acoustic characterisation experiments and was manufactured using additive manufacturing techniques. The design has been released to allow wider uptake in the research community. The efficacy of the chamber for acoustic characterisation has been explored with an experiment to measure the scattering of SonoVue® microbubbles at the fundamental frequency and second harmonic under interrogation from emissions in the frequency range of 1.6 to 6.4 MHz. The highest overall scattering values were measured at 1.6 MHz and decreased as the frequency increased, a result which is in agreement with previously published measurements. Statistical analysis of the acoustic scattering measurements have been performed and a significant difference, at the 5% significance level, was found between the samples containing contrast agent and the control sample containing only deionised water. These findings validate the proposed design for measuring the acoustic scattering characteristics of ultrasound contrast agents.
- 10 February 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (4) , 1818
Open AccessAn Open Access Chamber Designed for the Acoustic Characterisation of Microbubbles
Microbubbles are used as contrast agents in clinical ultrasound for Left Ventricular Opacification (LVO) and perfusion imaging. They are also the subject of promising research in therapeutics as a drug delivery mechanism or for sonoporation and co-administration. For maximum efficacy in these applications, it is important to understand the acoustic characteristics of the administered microbubbles. Despite this, there is significant variation in the experimental procedures and equipment used to measure the acoustic properties of microbubble populations. A chamber was designed to facilitate acoustic characterisation experiments and was manufactured using additive manufacturing techniques. The design has been released to allow wider uptake in the research community. The efficacy of the chamber for acoustic characterisation has been explored with an experiment to measure the scattering of SonoVue® microbubbles at the fundamental frequency and second harmonic under interrogation from emissions in the frequency range of 1.6 to 6.4 MHz. The highest overall scattering values were measured at 1.6 MHz and decreased as the frequency increased, a result which is in agreement with previously published measurements. Statistical analysis of the acoustic scattering measurements have been performed and a significant difference, at the 5% significance level, was found between the samples containing contrast agent and the control sample containing only deionised water. These findings validate the proposed design for measuring the acoustic scattering characteristics of ultrasound contrast agents.
- 22 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (2) , 270-280
High-Power Gallium Nitride HIFU Transmitter With Integrated Real-Time Current and Voltage Measurement
High-Intensity Focused Ultrasound (HIFU) therapy provides a non-invasive technique with which to destroy cancerous tissue without using ionizing radiation. To drive large single-element High-Intensity Focused Ultrasound (HIFU) transducers, ultrasound transmitters capable of delivering high powers at relevant frequencies are required. The acoustic power delivered to a transducers focal region will determine the treated area, and due to safety concerns and intervening layers of attenuation, control of this output power is critical. A typical setup involves large inefficient linear power amplifiers to drive the transducer. Switched mode transmitters allow for a more compact drive system with higher efficiencies, with multi-level transmitters allowing control over the output power. Real-time monitoring of power delivered can avoid damage to the transducer and injury to patients due to over treatment, and allow for precise control over the output power. This study demonstrates a transformer-less, high power, switched mode transmit transmitter based on Gallium-Nitride (GaN) transistors that is capable of delivering peak powers up to 1.8 kW at up to 600 Vpp, while operating at frequencies from DC to 5 MHz. The design includes a 12 b 16 MHz floating Current/Voltage (IV) measurement circuit to allow real-time high-side monitoring of the power delivered to the transducer allowing use with multi-element transducers.
- 22 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 15 (2) , 270-280
High-Power Gallium Nitride HIFU Transmitter With Integrated Real-Time Current and Voltage Measurement
High-Intensity Focused Ultrasound (HIFU) therapy provides a non-invasive technique with which to destroy cancerous tissue without using ionizing radiation. To drive large single-element High-Intensity Focused Ultrasound (HIFU) transducers, ultrasound transmitters capable of delivering high powers at relevant frequencies are required. The acoustic power delivered to a transducers focal region will determine the treated area, and due to safety concerns and intervening layers of attenuation, control of this output power is critical. A typical setup involves large inefficient linear power amplifiers to drive the transducer. Switched mode transmitters allow for a more compact drive system with higher efficiencies, with multi-level transmitters allowing control over the output power. Real-time monitoring of power delivered can avoid damage to the transducer and injury to patients due to over treatment, and allow for precise control over the output power. This study demonstrates a transformer-less, high power, switched mode transmit transmitter based on Gallium-Nitride (GaN) transistors that is capable of delivering peak powers up to 1.8 kW at up to 600 Vpp, while operating at frequencies from DC to 5 MHz. The design includes a 12 b 16 MHz floating Current/Voltage (IV) measurement circuit to allow real-time high-side monitoring of the power delivered to the transducer allowing use with multi-element transducers.
- Open Access
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 380-383
Motion Compensation for High-Frame-Rate Contrast-Enhanced Echocardiography Using Diverging Waves: Image Registration Versus Correlation-Based Method
By using diverging ultrasound waves, a B-mode image can be reconstructed from a single transmission with parallel beamforming. For echocardiography, this approach can provide a frame rate up to 5 kHz, which is two orders of magnitude faster than the most clinical scanners. However, image degradation arising from the lack of transmit focusing when using diverging waves, could not be alleviated by coherent compounding due to the effect of cardiac motion. The motion effects on high-frame-rate contrast-enhanced echocardiography (HFR CEE) when combining diverging waves and microbubble contrast agents were demonstrated in recent studies, with a two-stage correlation-based method and an image registration-based method proposed to enable coherent compounding. The current study compared these two methods for motion compensation in HFR CEE both in vitro and in vivo. For in vitro experiments with a rotating disk phantom, the correlation-based method improved the contrast ratio and contrast-to-noise-ratio by 5 dB and 3 dB, respectively. For the in vivo measurement, the correlation-based method provided a 6-dB improvement in contrast-to-tissue ratio.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 380-383
Open AccessMotion Compensation for High-Frame-Rate Contrast-Enhanced Echocardiography Using Diverging Waves: Image Registration Versus Correlation-Based Method
By using diverging ultrasound waves, a B-mode image can be reconstructed from a single transmission with parallel beamforming. For echocardiography, this approach can provide a frame rate up to 5 kHz, which is two orders of magnitude faster than the most clinical scanners. However, image degradation arising from the lack of transmit focusing when using diverging waves, could not be alleviated by coherent compounding due to the effect of cardiac motion. The motion effects on high-frame-rate contrast-enhanced echocardiography (HFR CEE) when combining diverging waves and microbubble contrast agents were demonstrated in recent studies, with a two-stage correlation-based method and an image registration-based method proposed to enable coherent compounding. The current study compared these two methods for motion compensation in HFR CEE both in vitro and in vivo. For in vitro experiments with a rotating disk phantom, the correlation-based method improved the contrast ratio and contrast-to-noise-ratio by 5 dB and 3 dB, respectively. For the in vivo measurement, the correlation-based method provided a 6-dB improvement in contrast-to-tissue ratio.
- Open Access
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1959-1962
Gallium Nitride Based High-Power Switched HIFU Pulser with Real-Time Current/Voltage Monitoring
High-Intensity Focussed Ultrasound (HIFU) techniques make use of ultrasound transducers capable of delivering high powers to be delivered at high frequencies. Real-time monitoring of power delivered can avoid damage to the transducer and injury to patients due to overexposure.This paper demonstrates the real-time current and voltage monitoring capabilities of a new Gallium-Nitride (GaN) based switched mode transmit pulser developed for the University of Leeds High-Intensity Focussed Ultrasound Array Research Platform (HIFUARP) system, which uses a novel approach of using an Analog Front End (AFE) floating on the transmitter output to provide high bandwidth current measurement.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1959-1962
Open AccessGallium Nitride Based High-Power Switched HIFU Pulser with Real-Time Current/Voltage Monitoring
High-Intensity Focussed Ultrasound (HIFU) techniques make use of ultrasound transducers capable of delivering high powers to be delivered at high frequencies. Real-time monitoring of power delivered can avoid damage to the transducer and injury to patients due to overexposure.This paper demonstrates the real-time current and voltage monitoring capabilities of a new Gallium-Nitride (GaN) based switched mode transmit pulser developed for the University of Leeds High-Intensity Focussed Ultrasound Array Research Platform (HIFUARP) system, which uses a novel approach of using an Analog Front End (AFE) floating on the transmitter output to provide high bandwidth current measurement.
- 12 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (2) , 239-247
HIFU Power Monitoring Using Combined Instantaneous Current and Voltage Measurement
During high-intensity focused ultrasound (HIFU) therapy, it is important that the electrical power delivered to the transducer is monitored to avoid underexposure or overexposure, ensure patient safety, and to protect the transducer itself. Due to ease of measurement, the transducer's potential difference may be as an indicator of power delivery. However, even when a transducer's complex impedance is well characterized at small amplitudes and matching networks are used, voltage-only (VO) monitoring cannot account for the presence of drive waveform distortion, changes to the acoustic path, or damage to the transducer. In this study, combined current and voltage (CCV) is proposed as a magnetic resonance imaging (MRI)-compatible, miniature alternative to bidirectional power couplers, which is compatible with switched amplifiers. For CCV power measurement, current probe data were multiplied by the voltage waveform and integrated in the frequency domain. Transducer efficiency was taken into account to predict acoustic power. The technique was validated with a radiation force balance (RFB). When using a typical HIFU transducer and amplifier, VO predictions and acoustic power had a maximum difference of 20%. However, under the same conditions, CCV only had a maximum difference of 5%. The technique was applied to several lesioning experiments and it was shown that when VO was used as a control between two amplifiers, there was up to a 38% difference in lesion area. This greatly reduced to a maximum of 5% once CCV was used instead. These results demonstrate that CCV can accurately predict real-time electrical power delivery, leading to safer HIFU treatments.
- 12 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (2) , 239-247
HIFU Power Monitoring Using Combined Instantaneous Current and Voltage Measurement
During high-intensity focused ultrasound (HIFU) therapy, it is important that the electrical power delivered to the transducer is monitored to avoid underexposure or overexposure, ensure patient safety, and to protect the transducer itself. Due to ease of measurement, the transducer's potential difference may be as an indicator of power delivery. However, even when a transducer's complex impedance is well characterized at small amplitudes and matching networks are used, voltage-only (VO) monitoring cannot account for the presence of drive waveform distortion, changes to the acoustic path, or damage to the transducer. In this study, combined current and voltage (CCV) is proposed as a magnetic resonance imaging (MRI)-compatible, miniature alternative to bidirectional power couplers, which is compatible with switched amplifiers. For CCV power measurement, current probe data were multiplied by the voltage waveform and integrated in the frequency domain. Transducer efficiency was taken into account to predict acoustic power. The technique was validated with a radiation force balance (RFB). When using a typical HIFU transducer and amplifier, VO predictions and acoustic power had a maximum difference of 20%. However, under the same conditions, CCV only had a maximum difference of 5%. The technique was applied to several lesioning experiments and it was shown that when VO was used as a control between two amplifiers, there was up to a 38% difference in lesion area. This greatly reduced to a maximum of 5% once CCV was used instead. These results demonstrate that CCV can accurately predict real-time electrical power delivery, leading to safer HIFU treatments.
- Open Access
- 18 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (2) , 359-371
High-Frame-Rate Contrast-Enhanced Echocardiography Using Diverging Waves: 2-D Motion Estimation and Compensation
Combining diverging ultrasound waves and microbubbles could improve contrast-enhanced echocardiography (CEE), by providing enhanced temporal resolution for cardiac function assessment over a large imaging field of view. However, current image formation techniques using coherent summation of echoes from multiple steered diverging waves (DWs) are susceptible to tissue and microbubble motion artifacts, resulting in poor image quality. In this study, we used correlation-based 2-D motion estimation to perform motion compensation for CEE using DWs. The accuracy of this motion estimation method was evaluated with Field II simulations. The root-mean-square velocity errors were 5.9% ± 0.2% and 19.5% ± 0.4% in the axial and lateral directions, when normalized to the maximum value of 62.8 cm/s which is comparable to the highest speed of blood flow in the left ventricle (LV). The effects of this method on image contrast ratio (CR) and contrast-to-noise ratio (CNR) were tested in vitro using a tissue mimicking rotating disk with a diameter of 10 cm. Compared against the control without motion compensation, a mean increase of 12 dB in CR and 7 dB in CNR were demonstrated when using this motion compensation method. The motion correction algorithm was tested in vivo on a CEE data set acquired with the Ultrasound Array Research Platform II performing coherent DW imaging. Improvement of the B-mode and contrast-mode image quality with cardiac motion and blood flow-induced microbubble motion was achieved. The results of motion estimation were further processed to interpret blood flow in the LV. This allowed for a triplex cardiac imaging technique, consisting of B mode, contrast mode, and 2-D vector flow imaging with a high frame rate of 250 Hz.
- 18 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 66 (2) , 359-371
Open AccessHigh-Frame-Rate Contrast-Enhanced Echocardiography Using Diverging Waves: 2-D Motion Estimation and Compensation
Combining diverging ultrasound waves and microbubbles could improve contrast-enhanced echocardiography (CEE), by providing enhanced temporal resolution for cardiac function assessment over a large imaging field of view. However, current image formation techniques using coherent summation of echoes from multiple steered diverging waves (DWs) are susceptible to tissue and microbubble motion artifacts, resulting in poor image quality. In this study, we used correlation-based 2-D motion estimation to perform motion compensation for CEE using DWs. The accuracy of this motion estimation method was evaluated with Field II simulations. The root-mean-square velocity errors were 5.9% ± 0.2% and 19.5% ± 0.4% in the axial and lateral directions, when normalized to the maximum value of 62.8 cm/s which is comparable to the highest speed of blood flow in the left ventricle (LV). The effects of this method on image contrast ratio (CR) and contrast-to-noise ratio (CNR) were tested in vitro using a tissue mimicking rotating disk with a diameter of 10 cm. Compared against the control without motion compensation, a mean increase of 12 dB in CR and 7 dB in CNR were demonstrated when using this motion compensation method. The motion correction algorithm was tested in vivo on a CEE data set acquired with the Ultrasound Array Research Platform II performing coherent DW imaging. Improvement of the B-mode and contrast-mode image quality with cardiac motion and blood flow-induced microbubble motion was achieved. The results of motion estimation were further processed to interpret blood flow in the LV. This allowed for a triplex cardiac imaging technique, consisting of B mode, contrast mode, and 2-D vector flow imaging with a high frame rate of 250 Hz.
- Open Access
- 29 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (12) , 2407-2417
HIFU Drive System Miniaturization Using Harmonic Reduced Pulsewidth Modulation
Switched excitation has the potential to improve on the cost, efficiency, and size of the linear amplifier circuitry currently used in high-intensity focused ultrasound (HIFU) systems. Existing switching schemes are impaired by high harmonic distortion or lack array apodisation capability, so require adjustable supplies and/or large power filters to be useful. A multilevel pulsewidth modulation (PWM) topology could address both of these issues but the switching-speed limitations of transistors mean that there are a limited number of pulses available in each waveform cycle. In this study, harmonic reduction PWM (HRPWM) is proposed as an algorithmic solution to the design of switched waveforms. Its appropriateness for HIFU was assessed by design of a high power five-level unfiltered amplifier and subsequent thermal-only lesioning of ex vivo chicken breast. Three switched waveforms of different electrical powers (16, 26, 35 W) were generated using the HRPWM algorithm. Lesion sizes were measured and compared with those made at the same electrical power using a linear amplifier and bi-level excitation. HRPWM produced symmetric, thermal-only lesions that were the same size as their linear amplifier equivalents (p > 0.05). At 16 W, bi-level excitation produced smaller lesions but at higher power levels large transients in the acoustic waveform nucleated undesired cavitation. These results demonstrate that HRPWM can minimize HIFU drive circuity size without the need for filters to remove harmonics or adjustable power supplies to achieve array apodisation.
- 29 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (12) , 2407-2417
Open AccessHIFU Drive System Miniaturization Using Harmonic Reduced Pulsewidth Modulation
Switched excitation has the potential to improve on the cost, efficiency, and size of the linear amplifier circuitry currently used in high-intensity focused ultrasound (HIFU) systems. Existing switching schemes are impaired by high harmonic distortion or lack array apodisation capability, so require adjustable supplies and/or large power filters to be useful. A multilevel pulsewidth modulation (PWM) topology could address both of these issues but the switching-speed limitations of transistors mean that there are a limited number of pulses available in each waveform cycle. In this study, harmonic reduction PWM (HRPWM) is proposed as an algorithmic solution to the design of switched waveforms. Its appropriateness for HIFU was assessed by design of a high power five-level unfiltered amplifier and subsequent thermal-only lesioning of ex vivo chicken breast. Three switched waveforms of different electrical powers (16, 26, 35 W) were generated using the HRPWM algorithm. Lesion sizes were measured and compared with those made at the same electrical power using a linear amplifier and bi-level excitation. HRPWM produced symmetric, thermal-only lesions that were the same size as their linear amplifier equivalents (p > 0.05). At 16 W, bi-level excitation produced smaller lesions but at higher power levels large transients in the acoustic waveform nucleated undesired cavitation. These results demonstrate that HRPWM can minimize HIFU drive circuity size without the need for filters to remove harmonics or adjustable power supplies to achieve array apodisation.
- Open Access
- 18 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (7) , 1193-1204
Combining Acoustic Trapping With Plane Wave Imaging for Localized Microbubble Accumulation in Large Vessels
The capability of accumulating microbubbles using ultrasound could be beneficial for enhancing targeted drug delivery. When microbubbles are used to deliver a therapeutic payload, there is a need to track them, for a localized release of the payload. In this paper, a method for localizing microbubble accumulation with fast image guidance is presented. A linear array transducer performed trapping of microbubble populations interleaved with plane wave imaging, through the use of a composite pulse sequence. The acoustic trap in the pressure field was created parallel with the direction of flow in a model of a vessel section. The acoustic trapping force resultant from the large gradients in the acoustic field was engendered to directly oppose the flowing microbubbles. This was demonstrated numerically with field simulations, and experimentally using an Ultrasound Array Research Platform II. SonoVue microbubbles at clinically relevant concentrations were pumped through a tissue-mimicking flow phantom and exposed to either the acoustic trap or a control ultrasonic field composed of a single-peak acoustic radiation force beam. Under the flow condition at a shear rate of 433 s -1 , the use of the acoustic trap led to lower speed estimations (p <; 0.05) in the center of the acoustic field, and an enhancement of 71% ± 28%(p <; 0.05) in microbubble image brightness.
- 18 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (7) , 1193-1204
Open AccessCombining Acoustic Trapping With Plane Wave Imaging for Localized Microbubble Accumulation in Large Vessels
The capability of accumulating microbubbles using ultrasound could be beneficial for enhancing targeted drug delivery. When microbubbles are used to deliver a therapeutic payload, there is a need to track them, for a localized release of the payload. In this paper, a method for localizing microbubble accumulation with fast image guidance is presented. A linear array transducer performed trapping of microbubble populations interleaved with plane wave imaging, through the use of a composite pulse sequence. The acoustic trap in the pressure field was created parallel with the direction of flow in a model of a vessel section. The acoustic trapping force resultant from the large gradients in the acoustic field was engendered to directly oppose the flowing microbubbles. This was demonstrated numerically with field simulations, and experimentally using an Ultrasound Array Research Platform II. SonoVue microbubbles at clinically relevant concentrations were pumped through a tissue-mimicking flow phantom and exposed to either the acoustic trap or a control ultrasonic field composed of a single-peak acoustic radiation force beam. Under the flow condition at a shear rate of 433 s -1 , the use of the acoustic trap led to lower speed estimations (p <; 0.05) in the center of the acoustic field, and an enhancement of 71% ± 28%(p <; 0.05) in microbubble image brightness.