JYJiang You

Jiang You

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiang You has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Online Fault Detection of Submarine DC Cables with Wide-range Coverage

    by Longlei Bai, Jingyi Zeng, Liang Zou, Zejun Ma, Bo Luo, Jiang You, Xiaoxiong Cai, Hui Peng

    In recent years, long-term power failures of submarine DC cables caused by seawater erosion and anchor damage have posed increasing challenges to the safe and stable operation of underwater transmission systems. Accurate and efficient fault location is therefore essential for improving the reliability of submarine cable insulation. However, the conventional spread spectrum time domain reflectometry (SSTDR) method suffers from limited measurement efficiency and accuracy, as the chip duration of the modulation sequence constrains its detectable range. In this paper, a mixed modulation method is proposed to extend the effective measurement range of SSTDR. M-sequences with different chip durations are multiplied and modulated using binary phase shift keying with a sinusoidal carrier to form a mixed signal containing multi-scale fault information. Based on theoretical analysis and experimental validation, submarine cable faults are simulated and analyzed for fault localization. The results show that the period of the m-sequence mixed is proportional to the measurement range, while the chip duration is positively correlated with the ranging blind zone. Based on this relationship, modulation experiments are conducted using m-sequences with chip durations of 1 μs and 0.1 μs. After mixed modulation, the effective ranging interval is extended to 10.47–3245.70 m, compared with 104.70–3245.70 m and 10.47–324.57 m for the two individual sequences, respectively. In addition, the range of the blind zone is reduced. These results indicate that the proposed mixed modulation method improves the applicability of SSTDR for submarine cable fault location.


  • Variable-Gain Decentralized Input Voltage Sharing for ISOP DC–DC Converters

    by Wei Zhou, Jiang You, Hui Peng, Liuzhong Zhang

    It is a critical challenge in modular input-series–output-parallel (ISOP) conversion systems without input voltage monitor and interconnected lines to achieve balanced input voltage sharing (IVS) and output voltage regulation (OVR) under wide load variation. A novel variable-gain decentralized inverse-droop control method supporting full modularity design is proposed to address this issue in this letter. By designing the inverse-droop gain as a function of each converter module’s average inductor current, the proposed method can eliminate the requirements for input voltage sampling, high-voltage galvanic isolation of control circuits, and interconnected lines, which are very essential for ISOP converter modularity design. Furthermore, it can effectively extend the operation area with excellent IVS performance, while the OVR of the ISOP converter can also be effectively guaranteed. The principle of the proposed method is elaborated, and the small-signal-based stability analysis for the IVS control system along with the output voltage control system design of the ISOP converter is also investigated. The experimental results validate the effectiveness of the proposed control method.


  • Implementation of Zero Steady-State Tracking Error for Half-Bridge Three-Level DC/DC Converter Using Modified Dynamic Evolution Control

    by Wei Zhou, Jiang You, Hui Peng, Liuzhong Zhang

    Isolated half-bridge three-level (IHBTL) dc/dc converter with high performance in dynamic control, output voltage tracking accuracy, and electromagnetic compatibility is needed in electric transportation systems such as electric vehicles (EVs) and all-electric ships (AEs), to convert high-voltage to supply low-voltage devices. The traditional dynamic evolution control (DEC) with a first-order evolution path offers excellent control performance in dynamic processes, and the tracking error can be forced to follow a designated path; however, it cannot achieve zero steady-state error of output voltage under external disturbances and modeling errors in practical applications. A modified DEC (MDEC) method using a second-order tracking error evolution path is proposed in this article to address the steady-state error issue by constructing an integration function into the derived control law. The derivation procedure, small-signal modeling, stability analysis, and control method comparison studies are presented. The simulation and experimental results on an IHBTL dc/dc converter are presented to demonstrate the effectiveness of this method.


  • A Novel Decentralized and Forced Common Duty Ratio Method for Input Voltage Sharing of ISOP Converter

    by Wei Zhou, Jiang You, Liuzhong Zhang, Hui Peng

    The input-series–output-parallel (ISOP) dc/dc converter is suitable for applications that require high input voltage and output current. In such cases, input voltage sharing across each individual module is crucial to guarantee the safety and reliability of the system. This article proposed a novel duty ratio feedforward control scheme to automatically balance the input voltage of different modules in the ISOP conversion system by ensuring that the duty ratio of each module remains consistent. Compared to the traditional common duty ratio strategy, this method does not require interconnections for information exchange, decentralizes the input voltage sharing (IVS) control strategy implementation to each individual module, and achieves a fully modular design. Furthermore, this approach eliminates the need for input voltage and current sampling, simplifying the control system design. The article outlines the principles and characteristics of the proposed method, followed by a stability analysis based on a small-signal model and a discussion on control system design. Finally, experimental results are presented to validate the effectiveness of the proposed control strategy.


  • An Underwater Simultaneous Wireless Power and Analog-Digital Hybrid Signal Transfer System

    by Bo Luo, Mengyao Wang, Jie Tang, Tiantian Wang, Longlei Bai, Jiang You

    An underwater simultaneous wireless power and analog-digital hybrid signal transfer system is proposed in this letter to meet the needs of analog and digital signal transmission in underwater sensor networks in seawater. The system transmits two digital signals and one analog signal through the same coil, meeting the practical needs of multiple signal transmissions, improving the communication rate, and retaining the precision and continuity of analog signals as well as the accuracy of digital signals. The system uses a coaxial coil coupling structure, with the outer ring for power transmission and the inner ring for signal transmission, featuring a simple and compact design. The experimental platform achieved a 400W output power, 1Mbps bidirectional digital signal transmission and 20kHz unidirectional analog signal transmission in seawater, with a transmission efficiency of 90.8%, verifying the feasibility of the proposed theory.


  • Automatic Input Voltage Sharing of ISOP Converter Using Duty Ratio Feedforward Control Without Interconnection and Input Voltage Monitor

    by Wei Zhou, Jiang You, Hui Peng, Liuzhong Zhang

    The input-series–output-parallel (ISOP) dc/dc converter is ideal for applications requiring high input voltage and large output current. Ensuring proper input voltage sharing across the different submodules on the series side is crucial for practical implementation in ISOP systems. This article proposes a novel duty ratio feedforward control scheme that automatically balances the input voltage amongst the modules in the ISOP conversion system. In this method, each module operates independently without the need for interconnections to facilitate information exchange, and input voltage monitoring is unnecessary. Instead, only output voltage and filter inductor current need to be sampled, eliminating the requirement for high voltage isolation in conditioning circuits. Therefore, a fully modular design is achievable in the ISOP converter, improving metrics such as complexity, cost and reliability. This article presents a detailed discussion of the principle, small-signal model-based stability analysis and control system design. Experimental results are presented to validate the effectiveness of the proposed control strategy.


  • Parameter Identification Method for Underwater Vehicle WPT System Based on Primary-Side Detection

    by Longlei Bai, Ju Ye, Zhiyong Ma, Ziye Zhang, Chaoqiang Jiang, Jiang You, Bo Luo, Liangshun Sun

    In the realm of underwater wireless power transmission systems, it is crucial to acquire system parameters accurately to ensure output stability. However, measuring these parameters in underwater environments presents a huge challenge. As a result, simplifying measurements through parameter identification becomes essential. The circuit model of the underwater wireless power transfer (WPT) system may require adjustments due to seawater conductivity, and utilizing current parameter identification methods is applicable to air, which can lead to notable inaccuracies in underwater parameter identification. This article presents an analytical model of the mutual inductance in the underwater WPT system, analyzes its impact on output power and transmission efficiency, and proposes a mutual inductance and load parameter identification method suitable for underwater WPT systems. This method identifies mutual inductance and load values by measuring the input impedance of the equivalent load network on the inverter side at both resonant and nonresonant frequencies. The parameter identification model of the proposed underwater WPT system has been theoretically derived and experimentally verified using the seriesseries (SS) compensation topology. The experimental results illustrate that the proposed parameter identification method effectively identifies both the mutual inductance model and the load of the underwater WPT system, with the load identification error being less than 2% and the mutual inductance identification error being less than 5%. Furthermore, mutual inductance and load information can be obtained from the primary side without communication, and the output voltage is controlled with an accuracy of less than 1.2% through parameter identification.


  • Front-End Parameter Identification Method Based on Adam-W Optimization Algorithm for Underwater Wireless Power Transfer System

    by Bo Luo, Huan Wu, Mengyao Wang, Fangrui Wang, Longlei Bai, Chaoqiang Jiang, Jiang You

    Monitoring coupler parameters in underwater wireless power transfer (UWPT) systems is crucial for improving the system transmission characteristics. Due to the eddy current effect, the equivalent circuits of the magnetic coupler are more complex and contain more parameters than those in air-based circuits. Traditional parameter identification methods, which rely on solving circuit matrix equations, often struggle with the complex UWPT systems or require significant computational resources to solve high-order multivariate equations. This article proposes a coupler parameter identification method based on the adaptive moment estimation with a weighted adjustment (Adam-W) optimization algorithm to address the multiparameter identification problems in the UWPT system. This method transforms the problem of solving high-order matrix equations into an optimization problem to address multiparameter identification problem caused by seawater eddy effect, which is challenging for traditional methods. In addition, it facilitates online monitoring of the characteristic parameters of the system's coupler by detecting the system's front-end input current and voltage without wireless communication and additional sensor modules, and exhibits better reliability in underwater environments. The experimental results show that the proposed Adam-W algorithm achieves a high parameter identification accuracy within 1 s and 94 iterations with an average error of 2.78%. Comparably, an average error of 56.74% is achieved by gradient descent and 41.49% by adaptive moment estimation, and 37.42% by particle swarm optimization in 150 iterations. The proposed Adam-W algorithm achieves higher accuracy in parameter identification of the UWPT system within a shorter time and demonstrates better applicability in seawater environments.


  • A Multiple Independent-Load Output Capacitive Power Transfer System With High Coupler Misalignment-Tolerance for Railway Applications

    by Bo Luo, Yuezhong Liu, Yiming Zhang, Longlei Bai, Yao Zhang, Zhulin Wang, Jiang You, Ruikun Mai

    Electronically controlled pneumatic (ECP) system is essential to ensure the railway transportation system's braking safety. Traditionally, the ECP system needs a long cable to supply power for each train body's brake controller. However, a train has many bumps, and the transmission lines and plugs easily fall off simultaneously. It brings severe challenges to the safe and reliable operation of the railway system. This paper proposes a capacitive power transfer (CPT) system to supply power for a long-distance and multiple-load ECP brake system to solve this problem. The proposed system has the following characteristics: 1. It can supply power to multiple loads simultaneously; 2. The variation of load resistance will not affect the other load; 3. The output of each load will not be largely affected by the coupler misalignment. The transmitter of the proposed CPT system adopts CL compensation, while the receivers adopt LCCL topology. The receiver not only receives the electric power for the load but also transfers the power to the next load. A scaled-down experimental prototype with three loads was implemented to verify the proposed theory. The experimental results agree well with the analysis. With a 200mm misalignment (2/3 length of coupler plates), the output power can reach 83.32W (150W rated). The change rate of the output voltage is less than 12% when other receivers are moved out.