Liuzhong Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Liuzhong Zhang has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Hui Peng
College of Intelligent Systems Science and Engineering, Harbin Engineering University, Harbin, China
4 shared publications - Jiang You
Yantai Research Institute, Harbin Engineering University, Yantai, China
4 shared publications - Wei Zhou
College of Intelligent Systems Science and Engineering, Harbin Engineering University, Harbin, China
4 shared publications
Latest Publications
- 26 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 1579-1584
Variable-Gain Decentralized Input Voltage Sharing for ISOP DC–DC Converters
It is a critical challenge in modular input-series–output-parallel (ISOP) conversion systems without input voltage monitor and interconnected lines to achieve balanced input voltage sharing (IVS) and output voltage regulation (OVR) under wide load variation. A novel variable-gain decentralized inverse-droop control method supporting full modularity design is proposed to address this issue in this letter. By designing the inverse-droop gain as a function of each converter module’s average inductor current, the proposed method can eliminate the requirements for input voltage sampling, high-voltage galvanic isolation of control circuits, and interconnected lines, which are very essential for ISOP converter modularity design. Furthermore, it can effectively extend the operation area with excellent IVS performance, while the OVR of the ISOP converter can also be effectively guaranteed. The principle of the proposed method is elaborated, and the small-signal-based stability analysis for the IVS control system along with the output voltage control system design of the ISOP converter is also investigated. The experimental results validate the effectiveness of the proposed control method.
- 26 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (2) , 1579-1584
Variable-Gain Decentralized Input Voltage Sharing for ISOP DC–DC Converters
It is a critical challenge in modular input-series–output-parallel (ISOP) conversion systems without input voltage monitor and interconnected lines to achieve balanced input voltage sharing (IVS) and output voltage regulation (OVR) under wide load variation. A novel variable-gain decentralized inverse-droop control method supporting full modularity design is proposed to address this issue in this letter. By designing the inverse-droop gain as a function of each converter module’s average inductor current, the proposed method can eliminate the requirements for input voltage sampling, high-voltage galvanic isolation of control circuits, and interconnected lines, which are very essential for ISOP converter modularity design. Furthermore, it can effectively extend the operation area with excellent IVS performance, while the OVR of the ISOP converter can also be effectively guaranteed. The principle of the proposed method is elaborated, and the small-signal-based stability analysis for the IVS control system along with the output voltage control system design of the ISOP converter is also investigated. The experimental results validate the effectiveness of the proposed control method.
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (6) , 13765-13776
Implementation of Zero Steady-State Tracking Error for Half-Bridge Three-Level DC/DC Converter Using Modified Dynamic Evolution Control
Isolated half-bridge three-level (IHBTL) dc/dc converter with high performance in dynamic control, output voltage tracking accuracy, and electromagnetic compatibility is needed in electric transportation systems such as electric vehicles (EVs) and all-electric ships (AEs), to convert high-voltage to supply low-voltage devices. The traditional dynamic evolution control (DEC) with a first-order evolution path offers excellent control performance in dynamic processes, and the tracking error can be forced to follow a designated path; however, it cannot achieve zero steady-state error of output voltage under external disturbances and modeling errors in practical applications. A modified DEC (MDEC) method using a second-order tracking error evolution path is proposed in this article to address the steady-state error issue by constructing an integration function into the derived control law. The derivation procedure, small-signal modeling, stability analysis, and control method comparison studies are presented. The simulation and experimental results on an IHBTL dc/dc converter are presented to demonstrate the effectiveness of this method.
- 18 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (6) , 13765-13776
Implementation of Zero Steady-State Tracking Error for Half-Bridge Three-Level DC/DC Converter Using Modified Dynamic Evolution Control
Isolated half-bridge three-level (IHBTL) dc/dc converter with high performance in dynamic control, output voltage tracking accuracy, and electromagnetic compatibility is needed in electric transportation systems such as electric vehicles (EVs) and all-electric ships (AEs), to convert high-voltage to supply low-voltage devices. The traditional dynamic evolution control (DEC) with a first-order evolution path offers excellent control performance in dynamic processes, and the tracking error can be forced to follow a designated path; however, it cannot achieve zero steady-state error of output voltage under external disturbances and modeling errors in practical applications. A modified DEC (MDEC) method using a second-order tracking error evolution path is proposed in this article to address the steady-state error issue by constructing an integration function into the derived control law. The derivation procedure, small-signal modeling, stability analysis, and control method comparison studies are presented. The simulation and experimental results on an IHBTL dc/dc converter are presented to demonstrate the effectiveness of this method.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 1235-1245
A Novel Decentralized and Forced Common Duty Ratio Method for Input Voltage Sharing of ISOP Converter
The input-series–output-parallel (ISOP) dc/dc converter is suitable for applications that require high input voltage and output current. In such cases, input voltage sharing across each individual module is crucial to guarantee the safety and reliability of the system. This article proposed a novel duty ratio feedforward control scheme to automatically balance the input voltage of different modules in the ISOP conversion system by ensuring that the duty ratio of each module remains consistent. Compared to the traditional common duty ratio strategy, this method does not require interconnections for information exchange, decentralizes the input voltage sharing (IVS) control strategy implementation to each individual module, and achieves a fully modular design. Furthermore, this approach eliminates the need for input voltage and current sampling, simplifying the control system design. The article outlines the principles and characteristics of the proposed method, followed by a stability analysis based on a small-signal model and a discussion on control system design. Finally, experimental results are presented to validate the effectiveness of the proposed control strategy.
- 6 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 1235-1245
A Novel Decentralized and Forced Common Duty Ratio Method for Input Voltage Sharing of ISOP Converter
The input-series–output-parallel (ISOP) dc/dc converter is suitable for applications that require high input voltage and output current. In such cases, input voltage sharing across each individual module is crucial to guarantee the safety and reliability of the system. This article proposed a novel duty ratio feedforward control scheme to automatically balance the input voltage of different modules in the ISOP conversion system by ensuring that the duty ratio of each module remains consistent. Compared to the traditional common duty ratio strategy, this method does not require interconnections for information exchange, decentralizes the input voltage sharing (IVS) control strategy implementation to each individual module, and achieves a fully modular design. Furthermore, this approach eliminates the need for input voltage and current sampling, simplifying the control system design. The article outlines the principles and characteristics of the proposed method, followed by a stability analysis based on a small-signal model and a discussion on control system design. Finally, experimental results are presented to validate the effectiveness of the proposed control strategy.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (8) , 11143-11156
Automatic Input Voltage Sharing of ISOP Converter Using Duty Ratio Feedforward Control Without Interconnection and Input Voltage Monitor
The input-series–output-parallel (ISOP) dc/dc converter is ideal for applications requiring high input voltage and large output current. Ensuring proper input voltage sharing across the different submodules on the series side is crucial for practical implementation in ISOP systems. This article proposes a novel duty ratio feedforward control scheme that automatically balances the input voltage amongst the modules in the ISOP conversion system. In this method, each module operates independently without the need for interconnections to facilitate information exchange, and input voltage monitoring is unnecessary. Instead, only output voltage and filter inductor current need to be sampled, eliminating the requirement for high voltage isolation in conditioning circuits. Therefore, a fully modular design is achievable in the ISOP converter, improving metrics such as complexity, cost and reliability. This article presents a detailed discussion of the principle, small-signal model-based stability analysis and control system design. Experimental results are presented to validate the effectiveness of the proposed control strategy.
- 28 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (8) , 11143-11156
Automatic Input Voltage Sharing of ISOP Converter Using Duty Ratio Feedforward Control Without Interconnection and Input Voltage Monitor
The input-series–output-parallel (ISOP) dc/dc converter is ideal for applications requiring high input voltage and large output current. Ensuring proper input voltage sharing across the different submodules on the series side is crucial for practical implementation in ISOP systems. This article proposes a novel duty ratio feedforward control scheme that automatically balances the input voltage amongst the modules in the ISOP conversion system. In this method, each module operates independently without the need for interconnections to facilitate information exchange, and input voltage monitoring is unnecessary. Instead, only output voltage and filter inductor current need to be sampled, eliminating the requirement for high voltage isolation in conditioning circuits. Therefore, a fully modular design is achievable in the ISOP converter, improving metrics such as complexity, cost and reliability. This article presents a detailed discussion of the principle, small-signal model-based stability analysis and control system design. Experimental results are presented to validate the effectiveness of the proposed control strategy.