HPHui Peng

Hui Peng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hui Peng has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Online Fault Detection of Submarine DC Cables with Wide-range Coverage

    by Longlei Bai, Jingyi Zeng, Liang Zou, Zejun Ma, Bo Luo, Jiang You, Xiaoxiong Cai, Hui Peng

    In recent years, long-term power failures of submarine DC cables caused by seawater erosion and anchor damage have posed increasing challenges to the safe and stable operation of underwater transmission systems. Accurate and efficient fault location is therefore essential for improving the reliability of submarine cable insulation. However, the conventional spread spectrum time domain reflectometry (SSTDR) method suffers from limited measurement efficiency and accuracy, as the chip duration of the modulation sequence constrains its detectable range. In this paper, a mixed modulation method is proposed to extend the effective measurement range of SSTDR. M-sequences with different chip durations are multiplied and modulated using binary phase shift keying with a sinusoidal carrier to form a mixed signal containing multi-scale fault information. Based on theoretical analysis and experimental validation, submarine cable faults are simulated and analyzed for fault localization. The results show that the period of the m-sequence mixed is proportional to the measurement range, while the chip duration is positively correlated with the ranging blind zone. Based on this relationship, modulation experiments are conducted using m-sequences with chip durations of 1 μs and 0.1 μs. After mixed modulation, the effective ranging interval is extended to 10.47–3245.70 m, compared with 104.70–3245.70 m and 10.47–324.57 m for the two individual sequences, respectively. In addition, the range of the blind zone is reduced. These results indicate that the proposed mixed modulation method improves the applicability of SSTDR for submarine cable fault location.


  • Variable-Gain Decentralized Input Voltage Sharing for ISOP DC–DC Converters

    by Wei Zhou, Jiang You, Hui Peng, Liuzhong Zhang

    It is a critical challenge in modular input-series–output-parallel (ISOP) conversion systems without input voltage monitor and interconnected lines to achieve balanced input voltage sharing (IVS) and output voltage regulation (OVR) under wide load variation. A novel variable-gain decentralized inverse-droop control method supporting full modularity design is proposed to address this issue in this letter. By designing the inverse-droop gain as a function of each converter module’s average inductor current, the proposed method can eliminate the requirements for input voltage sampling, high-voltage galvanic isolation of control circuits, and interconnected lines, which are very essential for ISOP converter modularity design. Furthermore, it can effectively extend the operation area with excellent IVS performance, while the OVR of the ISOP converter can also be effectively guaranteed. The principle of the proposed method is elaborated, and the small-signal-based stability analysis for the IVS control system along with the output voltage control system design of the ISOP converter is also investigated. The experimental results validate the effectiveness of the proposed control method.


  • Implementation of Zero Steady-State Tracking Error for Half-Bridge Three-Level DC/DC Converter Using Modified Dynamic Evolution Control

    by Wei Zhou, Jiang You, Hui Peng, Liuzhong Zhang

    Isolated half-bridge three-level (IHBTL) dc/dc converter with high performance in dynamic control, output voltage tracking accuracy, and electromagnetic compatibility is needed in electric transportation systems such as electric vehicles (EVs) and all-electric ships (AEs), to convert high-voltage to supply low-voltage devices. The traditional dynamic evolution control (DEC) with a first-order evolution path offers excellent control performance in dynamic processes, and the tracking error can be forced to follow a designated path; however, it cannot achieve zero steady-state error of output voltage under external disturbances and modeling errors in practical applications. A modified DEC (MDEC) method using a second-order tracking error evolution path is proposed in this article to address the steady-state error issue by constructing an integration function into the derived control law. The derivation procedure, small-signal modeling, stability analysis, and control method comparison studies are presented. The simulation and experimental results on an IHBTL dc/dc converter are presented to demonstrate the effectiveness of this method.


  • A Novel Decentralized and Forced Common Duty Ratio Method for Input Voltage Sharing of ISOP Converter

    by Wei Zhou, Jiang You, Liuzhong Zhang, Hui Peng

    The input-series–output-parallel (ISOP) dc/dc converter is suitable for applications that require high input voltage and output current. In such cases, input voltage sharing across each individual module is crucial to guarantee the safety and reliability of the system. This article proposed a novel duty ratio feedforward control scheme to automatically balance the input voltage of different modules in the ISOP conversion system by ensuring that the duty ratio of each module remains consistent. Compared to the traditional common duty ratio strategy, this method does not require interconnections for information exchange, decentralizes the input voltage sharing (IVS) control strategy implementation to each individual module, and achieves a fully modular design. Furthermore, this approach eliminates the need for input voltage and current sampling, simplifying the control system design. The article outlines the principles and characteristics of the proposed method, followed by a stability analysis based on a small-signal model and a discussion on control system design. Finally, experimental results are presented to validate the effectiveness of the proposed control strategy.


  • Automatic Input Voltage Sharing of ISOP Converter Using Duty Ratio Feedforward Control Without Interconnection and Input Voltage Monitor

    by Wei Zhou, Jiang You, Hui Peng, Liuzhong Zhang

    The input-series–output-parallel (ISOP) dc/dc converter is ideal for applications requiring high input voltage and large output current. Ensuring proper input voltage sharing across the different submodules on the series side is crucial for practical implementation in ISOP systems. This article proposes a novel duty ratio feedforward control scheme that automatically balances the input voltage amongst the modules in the ISOP conversion system. In this method, each module operates independently without the need for interconnections to facilitate information exchange, and input voltage monitoring is unnecessary. Instead, only output voltage and filter inductor current need to be sampled, eliminating the requirement for high voltage isolation in conditioning circuits. Therefore, a fully modular design is achievable in the ISOP converter, improving metrics such as complexity, cost and reliability. This article presents a detailed discussion of the principle, small-signal model-based stability analysis and control system design. Experimental results are presented to validate the effectiveness of the proposed control strategy.


  • Mechanism Characterization and Nondestructive Inspection Method of Thermal Degradation Faults in EPDM Cable Termination

    by Longlei Bai, Mingwei Su, Liangshun Sun, Shaogui Fan, Shuai Xun, Manjun Huang, Hui Peng

    There is a significant positive proportional correlation between the condition of ethylene propylene diene monomer (EPDM) insulation and partial discharge (PD) characteristics in electric multiple units (EMUs) cable termination. Especially for the cable terminations with long service life, the aging effect of EPDM insulation material is significant due to long-term high-current load. In this article, electrical deterioration and PD development of EPDM insulation under long-term thermal degradation is conducted. During the test process, the phase-resolved PD (PRPD) analysis, PD inception voltage (PDIV), physicochemical properties, and flashover voltage of EPDM samples with different thermal degradation are measured. The relationship between the thermal degradation extent of EPDM insulation and PD characteristics is also proposed. The results show that electrical deterioration of the aged sample can be divided into four gradations by PD amplitude and pulse repetition rate. In the four gradations, the shape of the PRPD spectrum in every gradation changes significantly with different thermal degradations. Surface morphologies of EPDM insulation show different features such as gully areas and white particles. The results of the Fourier transform infrared (FTIR) spectroscopy test indicate that the increase of oxygen-containing groups and free radicals are the key reasons for the rapid PD development process of cable insulation under different electrical gradations and thermal-oxygen degradations.