BRBenjamin Reig

Benjamin Reig

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Benjamin Reig has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of Ethylene Oxide Sterilization on PEDOT:PSS Electrophysiology Electrodes

    by Ali Maziz, Clement Cointe, Benjamin Reig, Christian Bergaud

    Poly(3,4-ethylenedioxythiophene)–polystyrene sulfonate (PEDOT:PSS) is widely used to fabricate conductive organic coatings for electrodes in electrophysiology. As these devices move toward clinical translation, establishing sterilization methods that preserve their functional properties is essential. Ethylene oxide (EtO) is routinely used for sterilizing heat- and moisture-sensitive medical devices due to its high penetration efficiency and low thermal load. However, the absence of systematic studies evaluating its impact on PEDOT:PSS raises concerns about the compatibility of EtO sterilization with organic electrophysiology interfaces. Here, we report the first comprehensive evaluation of EtO sterilization on PEDOT:PSS electrodes electrochemically deposited onto cortical interfaces designed for intraoperative monitoring and stimulation. EtO exposure induced only minimal changes in surface topography, with no detectable alteration of the electrical or electrochemical performance of the electrodes. Impedance spectroscopy, cyclic voltammetry, and charge-injection capacity measurements all revealed that EtO-treated electrodes retained properties comparable to untreated controls. Moreover, EtO-sterilized PEDOT:PSS coatings demonstrated robust long-term stability under accelerated lifetime testing, exhibiting negligible degradation over extended operation. These findings demonstrate that EtO sterilization is fully compatible with PEDOT:PSS-based bioelectronic interfaces and constitutes a viable pathway toward their safe and effective integration into clinical electrophysiology. This work represents an important step toward translating organic conducting polymer technologies into real-world biomedical applications.


  • Open Access

    Implementation of Integrated VCSEL-Based Optical Feedback Interferometry Microfluidic Sensor System with Polymer Microoptics

    by Yu Zhao, Qingyue Li, Jean-Baptiste Doucet, Pierre-François Calmon, Fabien Mesnilgrente, Benjamin Reig, Clément Tronche, Thierry Camps, Julien Perchoux, Véronique Bardinal

    Using the optical feedback interferometry (OFI) technique, we demonstrated a miniaturized and compact sensor system based on a dedicated optical source for flowmetry at the micro-scale. In the system, polymer microlenses were integrated directly on a VCSEL (vertical-cavity surface-emitting laser) chip and the microfluidic channel chip surface using polymer-based micro-fabrication technologies. In particular, at a post-process stage, we integrated a collimation lens on a VCSEL chip of small dimensions (200 µm × 200 µm × 150 µm). This process was enabled by the soft-printing of dry thick resist films and through direct laser writing technology. We performed flow rate measurements using this new compact system, with a conventional bulk glass lens configuration for system performance evaluation. A maximum 33 dB signal-to-noise ratio was achieved from this novel ultra-compact system. To our knowledge, this is the highest signal level achieved by existing OFI based flowmetry sensors.


  • Open Access

    Uniform Fabrication of Moems Arrays Using Dry Thick Resist Films

    by Thierry Camps, Sami Abada, Benjamin Reig, Jean-Baptiste Doucet, Rémi Courson, Laurène Salvi, Benjamin Boisnard, Emmanuelle Daran, Véronique Bardinal

    This study aims at focusing a laser beam at the center of a microfluidic channel for optical bio-sensing applications thanks to the collective integration of tunable microlens arrays on VCSELs devices. High aspect-ratio polymer-based MOEMS are successfully fabricated on small-sized samples using thick dry photoresist films. Such dry films are easier to use and less expensive than standard thick SU-8 and can be efficiently stacked on fragile GaAs samples using a soft-thermal-printing technique. By combining double UV exposure and planar metallization, uniform fabrication of MOEMS arrays is enabled and fabricated devices exhibit reproducible electro-thermal behavior.

  • Advances in Polymer-Based Optical MEMS Fabrication for VCSEL Beam Shaping

    by Veronique Bardinal, Thierry Camps, Benjamin Reig, Sami Abada, Emmanuelle Daran, Jean-Baptiste Doucet

    In this paper, we discuss the design, fabrication, and characterization of electrothermally actuated polymer-based microoptical electromechanical microsystems (MOEMS) for active microoptics in vertical cavity surface emitting laser (VCSEL) devices. We describe in particular the principle of a SU8-based MOEMS designed for single-mode VCSEL beam active focusing. The ultimate objective is the realization of parallel compact optical scanners for sensing applications using collective and low-cost technologies. After discussing the advantages of the epoxy resist SU-8 for fabricating an integrated movable lens on active optical devices, we present our latest advances in technology for ensuring precise MOEMS fabrication on small III-V samples and for achieving accurate alignment of lenses on suspended circular membranes. Finally, we present our first results on the beam focusing of multimode VCSELs, which demonstrate the feasibility of our approach and could provide new insights in the MEMS-VCSEL field.