Yuki Nakashima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yuki Nakashima has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Fuminori Hirayama
National Institute of Advanced Industrial Science and Technology
4 shared publications - Noriko Y. Yamasaki
Institute of Space and Astronautical Science (ISAS)
4 shared publications - Satoshi Kohjiro
National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
4 shared publications - Shuuichi Nagasawa
National Institute of Advanced Industrial Science and Technology (AIST)
4 shared publications - Akira Sato
National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
3 shared publications - Hirotake Yamamori
National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
3 shared publications
Latest Publications
- 21 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 3501006
Investigating the Performance of RPM JTWPAs by Optimizing LC-Resonator Elements
Resonant phase-matched Josephson traveling-wave parametric amplifiers (RPM JTWPAs) play a key role in quantum computing and quantum information applications due to their low-noise, broadband amplification, and quadrature squeezing capabilities. This research focuses on optimizing RPM JTWPAs through numerical optimization of parametrized resonator elements to maximize gain, bandwidth and quadrature squeezing. Our results show that optimized resonators can increase the maximum gain and squeezing by more than 5 dB in the ideal noiseless case. However, introducing the effects of loss through a lumped-element model reveals that gain saturates with increasing loss, while squeezing modes degrade rapidly, regardless of resonator optimization. These results highlight the potential of resonator design to significantly improve amplifier performance, as well as the challenges posed by current fabrication technologies and inherent losses.
- 21 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 3501006
Investigating the Performance of RPM JTWPAs by Optimizing LC-Resonator Elements
Resonant phase-matched Josephson traveling-wave parametric amplifiers (RPM JTWPAs) play a key role in quantum computing and quantum information applications due to their low-noise, broadband amplification, and quadrature squeezing capabilities. This research focuses on optimizing RPM JTWPAs through numerical optimization of parametrized resonator elements to maximize gain, bandwidth and quadrature squeezing. Our results show that optimized resonators can increase the maximum gain and squeezing by more than 5 dB in the ideal noiseless case. However, introducing the effects of loss through a lumped-element model reveals that gain saturates with increasing loss, while squeezing modes degrade rapidly, regardless of resonator optimization. These results highlight the potential of resonator design to significantly improve amplifier performance, as well as the challenges posed by current fabrication technologies and inherent losses.
- Open Access
- 22 October 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (4)
Performance enhancement in Josephson traveling-wave parametric amplifiers by tailoring the relative distance between junctions
Josephson traveling-wave parametric amplifiers with heterogeneously spaced junctions are theoretically investigated. We consider unit cells with three junctions and characterize their interaction by spatially displaced fields defined by node fluxes. To solve this problem we define the system action and apply the variational principle to obtain the static action, which determines the equations of motion. This work shows that gain and bandwidth can be increased by modifying the relative distance between junctions within the same unit cell, thus increasing the effective nonlinear interaction. We find an optimal sub-unit-cell size ratio, which maximizes both gain and bandwidth, while equally spaced junctions offer minimum performance. Even though this method does not rely on phase matching, the same device can operate at different pump frequencies, it requires a very large number of JJs to achieve gains above 20 dB. We show that this method can be combined with resonant-phase matching and predicts an ideal gain above 29 dB on a 4-GHz bandwidth with 1998 junctions. Despite possible challenges fabricating devices at the optimal sub-unit-cell size with current technologies, substantial gain increase can still be achieved at suboptimal sizes.
- 22 October 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (4)
Open AccessPerformance enhancement in Josephson traveling-wave parametric amplifiers by tailoring the relative distance between junctions
Josephson traveling-wave parametric amplifiers with heterogeneously spaced junctions are theoretically investigated. We consider unit cells with three junctions and characterize their interaction by spatially displaced fields defined by node fluxes. To solve this problem we define the system action and apply the variational principle to obtain the static action, which determines the equations of motion. This work shows that gain and bandwidth can be increased by modifying the relative distance between junctions within the same unit cell, thus increasing the effective nonlinear interaction. We find an optimal sub-unit-cell size ratio, which maximizes both gain and bandwidth, while equally spaced junctions offer minimum performance. Even though this method does not rely on phase matching, the same device can operate at different pump frequencies, it requires a very large number of JJs to achieve gains above 20 dB. We show that this method can be combined with resonant-phase matching and predicts an ideal gain above 29 dB on a 4-GHz bandwidth with 1998 junctions. Despite possible challenges fabricating devices at the optimal sub-unit-cell size with current technologies, substantial gain increase can still be achieved at suboptimal sizes.
- Open Access
Investigating the performance of RPM JTWPAs by optimizing LC-resonator elements
Resonant phase-matched Josephson traveling-wave parametric amplifiers (RPM JTWPAs) play a key role in quantum computing and quantum information applications due to their low-noise, broadband amplification, and quadrature squeezing capabilities. This research focuses on optimizing RPM JTWPAs through numerical optimization of parametrized resonator elements to maximize gain, bandwidth and quadrature squeezing. Our results show that optimized resonators can increase the maximum gain and squeezing by more than 5 dB in the ideal noiseless case. However, introducing the effects of loss through a lumped-element model reveals that gain saturates with increasing loss, while squeezing modes degrade rapidly, regardless of resonator optimization. These results highlight the potential of resonator design to significantly improve amplifier performance, as well as the challenges posed by current fabrication technologies and inherent losses.
Open AccessInvestigating the performance of RPM JTWPAs by optimizing LC-resonator elements
Resonant phase-matched Josephson traveling-wave parametric amplifiers (RPM JTWPAs) play a key role in quantum computing and quantum information applications due to their low-noise, broadband amplification, and quadrature squeezing capabilities. This research focuses on optimizing RPM JTWPAs through numerical optimization of parametrized resonator elements to maximize gain, bandwidth and quadrature squeezing. Our results show that optimized resonators can increase the maximum gain and squeezing by more than 5 dB in the ideal noiseless case. However, introducing the effects of loss through a lumped-element model reveals that gain saturates with increasing loss, while squeezing modes degrade rapidly, regardless of resonator optimization. These results highlight the potential of resonator design to significantly improve amplifier performance, as well as the challenges posed by current fabrication technologies and inherent losses.
- 21 September 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (12) , 122601
Low-noise microwave SQUID multiplexed readout of 38 x-ray transition-edge sensor microcalorimeters
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of (where is the magnetic flux quantum), equivalent to . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a contribution of readout noise, i.e., 0.9–1.7 eV.- 21 September 2020
- Published by AIP Publishing in Applied Physics Letters
- Vol. 117 (12) , 122601
Low-noise microwave SQUID multiplexed readout of 38 x-ray transition-edge sensor microcalorimeters
We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of (where is the magnetic flux quantum), equivalent to . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a contribution of readout noise, i.e., 0.9–1.7 eV.- 18 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Investigation of Large Coupling Between TES X-Ray Microcalorimeter and Microwave Multiplexer Based on Microstrip SQUID
We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics were evaluated, and the results showed that the distortion of the SQUID characteristics and the degradation of its noise performance were not clearly observed. Finally, we have developed a MW-Mux microstrip SQUID with a low current noise of $\rm \lt 20 pA/\sqrt{Hz}$ which is below the typical noise of our TES X-ray microcalorimeter, $\rm 30 pA/\sqrt{Hz}$ .- 18 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-5
Investigation of Large Coupling Between TES X-Ray Microcalorimeter and Microwave Multiplexer Based on Microstrip SQUID
We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics were evaluated, and the results showed that the distortion of the SQUID characteristics and the degradation of its noise performance were not clearly observed. Finally, we have developed a MW-Mux microstrip SQUID with a low current noise of $\rm \lt 20 pA/\sqrt{Hz}$ which is below the typical noise of our TES X-ray microcalorimeter, $\rm 30 pA/\sqrt{Hz}$ .- 16 August 2018
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 193 (3-4) , 618-625
Readout of X-ray Pulses from a Single-pixel TES Microcalorimeter with Microwave Multiplexer Based on SQUIDs Directly Coupled to Resonators
- 16 August 2018
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 193 (3-4) , 618-625
Readout of X-ray Pulses from a Single-pixel TES Microcalorimeter with Microwave Multiplexer Based on SQUIDs Directly Coupled to Resonators
- 1 January 2017
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Electronics Express
- Vol. 14 (11) , 20170271
Adjustable SQUID-resonator direct coupling in microwave SQUID multiplexer for TES microcalorimeter array
- 1 January 2017
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Electronics Express
- Vol. 14 (11) , 20170271
Adjustable SQUID-resonator direct coupling in microwave SQUID multiplexer for TES microcalorimeter array
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 74-77
Cluster Carbon ion implantation for NMOS device fabrication improvements
To achieve an ultra-shallow junction formation with low resistivity, Cluster Carbon (CC) co-implantation for NMOS source drain and source drain extension condition are investigated. It is found that using CC co-implantation, Phosphorus (P) TED was suppressed and the lower junction depth Xj is achieved. The sheet resistivity Rs is increased with the increment of the Carbon dose, but the Rs×Xj product has a minimum condition is confirmed. From the experimental data, it is shown that the Cluster Carbon ion implantation (CCII) condition is important to suppress P TED effectively.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 74-77
Cluster Carbon ion implantation for NMOS device fabrication improvements
To achieve an ultra-shallow junction formation with low resistivity, Cluster Carbon (CC) co-implantation for NMOS source drain and source drain extension condition are investigated. It is found that using CC co-implantation, Phosphorus (P) TED was suppressed and the lower junction depth Xj is achieved. The sheet resistivity Rs is increased with the increment of the Carbon dose, but the Rs×Xj product has a minimum condition is confirmed. From the experimental data, it is shown that the Cluster Carbon ion implantation (CCII) condition is important to suppress P TED effectively.