Daniil A. Zuza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daniil A. Zuza has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Irina Aleksandrovna Kurzina
Chemistry Department, National Research Tomsk State University, Arkady Ivanov St. 49, 634028 Tomsk, Russia
6 shared publications - Irina V. Vasenina
P.N. Lebedev Physical Institute, 53 Leninsky Prospekt, Moscow 119333, Russia
5 shared publications - Olesya A. Laput
National Research Tomsk State University, Tomsk, Russia
5 shared publications - Vitaly O. Nekhoroshev
Tomsk Polytechnic University
3 shared publications - Alexander V. Batrakov
Institute of High Current Electronics of the Siberian Branch of the Russian Academy of Sciences, Tomsk, Russia
2 shared publications I.A. Kurzina
2 shared publications
Latest Publications
- 1 February 2024
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 60 (2) , 119-131
Analysis and NDT Applications of a Gas Discharge Electroacoustic Transducer
In this study, a gas discharge electroacoustic transducer (GDEAT) based on a pulsed electric discharge in the air under atmospheric pressure has been investigated. The acoustic characteristic of GDEATs have been determined in the frequency range from 40 Hz to 4 MHz by evaluating acoustic pressure and recording amplitude–frequency characteristics of membranes. The electrothermoacoustic processes have been studied in open type gas discharge systems where the electrode space is in a direct contact with the environment. Some features of using the above-mentioned GDEATs in material nondestructive testing (NDT) have been demonstrated. It has been shown that, on the one hand, the wear of both electrodes and insulation limits the work life of transducer’s electrode system; however, on the other hand, this may lead to deposition of microparticles on the test object surface. The wear of the electrode system was evaluated quantitatively. The results of the chemical analysis of the deposited microparticles are presented. The possibility of using GDEATs for noncontact stimulation of local resonant vibrations in subsurface defects and visualizing vibrations by means of laser Doppler vibrometry is shown in the case of NDT of a glass fiber composite.
- 1 February 2024
- Published by Pleiades Publishing Ltd in Russian Journal of Nondestructive Testing
- Vol. 60 (2) , 119-131
Analysis and NDT Applications of a Gas Discharge Electroacoustic Transducer
In this study, a gas discharge electroacoustic transducer (GDEAT) based on a pulsed electric discharge in the air under atmospheric pressure has been investigated. The acoustic characteristic of GDEATs have been determined in the frequency range from 40 Hz to 4 MHz by evaluating acoustic pressure and recording amplitude–frequency characteristics of membranes. The electrothermoacoustic processes have been studied in open type gas discharge systems where the electrode space is in a direct contact with the environment. Some features of using the above-mentioned GDEATs in material nondestructive testing (NDT) have been demonstrated. It has been shown that, on the one hand, the wear of both electrodes and insulation limits the work life of transducer’s electrode system; however, on the other hand, this may lead to deposition of microparticles on the test object surface. The wear of the electrode system was evaluated quantitatively. The results of the chemical analysis of the deposited microparticles are presented. The possibility of using GDEATs for noncontact stimulation of local resonant vibrations in subsurface defects and visualizing vibrations by means of laser Doppler vibrometry is shown in the case of NDT of a glass fiber composite.
- Open Access
- 1 January 2024
- Published by Tomsk State University in Vestnik Тomskogo gosudarstvennogo universiteta. Khimiya
- No. 34,p. 120-131
Organosilicon coating mass distribution in plasma-chemical reactor based on glow discharge in gas flow
Using the Plasma-Enhanced Chemical Vapour Deposition (PECVD) method, it is possible to synthesize a wide range of different materials, in particular, organosilicon polymer-like coatings. In the present work, a plasma-chemical reactor with coaxial hollow electrodes based on a DC glow discharge maintained in a plasmaforming gas flow at low pressure is used for deposition of a polymer-like coating. Argon was used as a plasma gas with a flow rate of 230 mg/min. Hexamethyldisiloxane was used as a precursor for deposition. Hexamethyldisiloxane was a molecular impurity in the inert gas flow and its flow rate was 10 mg/min. The purpose of the present work is an experimental study of the mass distribution of deposited organosilicon polymer-like coating on various constituent parts of the plasma chemical system based on glow discharge - on the internal surfaces of the reactor and on the substrate located at a distance of 15 mm from the reactor outlet. The experiment showed that at a discharge power of 30 W the total measured mass of the coating amounted to 33 mg. Thus, the mass conversion of the initial substance was over 33%. It is shown that about 90% of the total measured mass of the coating was deposited inside the plasma chemical reactor - on the inner surface of the hollow cathode and the inner surface of the glass tube, and 10% on the substrate. Thus, the present system can be used not only for remote local deposition but also for coating the inner walls of the tubes with a polymer-like coating. It was also revealed that due to the different conditions of processes in the cathode layers and the plasma of the positive column of the glow discharge, some peculiarities of deposition on different surfaces in the system appear. For example, the microstructure of the coatings obtained on the cathode, on the glass tube and on the substrate was investigated using an optical microscope. In this way it was revealed that the coatings consist of rounded microparticles and have a significant difference - the average size of microparticles on the glass tube and substrate cathode is 2-5 microns, which is an order of magnitude lower than the average size of particles deposited on the cathode.
- 1 January 2024
- Published by Tomsk State University in Vestnik Тomskogo gosudarstvennogo universiteta. Khimiya
- No. 34,p. 120-131
Open AccessOrganosilicon coating mass distribution in plasma-chemical reactor based on glow discharge in gas flow
Using the Plasma-Enhanced Chemical Vapour Deposition (PECVD) method, it is possible to synthesize a wide range of different materials, in particular, organosilicon polymer-like coatings. In the present work, a plasma-chemical reactor with coaxial hollow electrodes based on a DC glow discharge maintained in a plasmaforming gas flow at low pressure is used for deposition of a polymer-like coating. Argon was used as a plasma gas with a flow rate of 230 mg/min. Hexamethyldisiloxane was used as a precursor for deposition. Hexamethyldisiloxane was a molecular impurity in the inert gas flow and its flow rate was 10 mg/min. The purpose of the present work is an experimental study of the mass distribution of deposited organosilicon polymer-like coating on various constituent parts of the plasma chemical system based on glow discharge - on the internal surfaces of the reactor and on the substrate located at a distance of 15 mm from the reactor outlet. The experiment showed that at a discharge power of 30 W the total measured mass of the coating amounted to 33 mg. Thus, the mass conversion of the initial substance was over 33%. It is shown that about 90% of the total measured mass of the coating was deposited inside the plasma chemical reactor - on the inner surface of the hollow cathode and the inner surface of the glass tube, and 10% on the substrate. Thus, the present system can be used not only for remote local deposition but also for coating the inner walls of the tubes with a polymer-like coating. It was also revealed that due to the different conditions of processes in the cathode layers and the plasma of the positive column of the glow discharge, some peculiarities of deposition on different surfaces in the system appear. For example, the microstructure of the coatings obtained on the cathode, on the glass tube and on the substrate was investigated using an optical microscope. In this way it was revealed that the coatings consist of rounded microparticles and have a significant difference - the average size of microparticles on the glass tube and substrate cathode is 2-5 microns, which is an order of magnitude lower than the average size of particles deposited on the cathode.
- Open Access
- 1 January 2024
- Published by Tomsk State University in Vestnik Тomskogo gosudarstvennogo universiteta. Khimiya
- No. 34,p. 106-119
Chemical constitution of coatings deposited under hexamethyldisiloxane activation in a glow discharge in a gas flow
The aim of the present work is to reveal peculiarities and regularities of formation of chemical constitution of polymer-like coatings deposited under plasmachemical activation of hexamethyldisiloxane in cathode layers and positive column plasma of glow discharge. The glow discharge was maintained in an argon/hexamethyldisiloxane mixture flow. The argon flow rate was 230 mg/min. The coatings were deposited in six different modes of the plasma-chemical system. The modes were determined by the flow rate of hexamethyldisiloxane, which ranged from 1 to 10 mg/min, and the average discharge current, which was set between 5 and 50 mA. The chemical constitution of the obtained coatings was identified using X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. It is shown that varying the discharge current and hexamethyldisiloxane flow rate in this system produces a wide range of coatings of different chemical constitution. Four different types of coatings obtained were identified: polymethylsiloxane-like structure cross-linked with aliphatic hydrocarbon links with high (C/Si = 9.4) and low (C/Si = 2.9) hydrocarbon linkages, polyhedral oligomeric silsesquioxanes cross-linked with carbosilane, siloxane and aliphatic links with high (C/Si = 5.1) and low (C/Si = 1.5) hydrocarbon linkages. A significant effect of hexamethyldisiloxane flow rate on the chemical structure was found. The most interesting feature of some of the obtained organosilicon coatings is the high relative carbon content. The amount of hydrocarbon links in the coating was found to increase with discharge current. The assumption of formation of hydrocarbon film-forming particles in the cathode layers of the discharge due to ion-induced processes is put forward.
- 1 January 2024
- Published by Tomsk State University in Vestnik Тomskogo gosudarstvennogo universiteta. Khimiya
- No. 34,p. 106-119
Open AccessChemical constitution of coatings deposited under hexamethyldisiloxane activation in a glow discharge in a gas flow
The aim of the present work is to reveal peculiarities and regularities of formation of chemical constitution of polymer-like coatings deposited under plasmachemical activation of hexamethyldisiloxane in cathode layers and positive column plasma of glow discharge. The glow discharge was maintained in an argon/hexamethyldisiloxane mixture flow. The argon flow rate was 230 mg/min. The coatings were deposited in six different modes of the plasma-chemical system. The modes were determined by the flow rate of hexamethyldisiloxane, which ranged from 1 to 10 mg/min, and the average discharge current, which was set between 5 and 50 mA. The chemical constitution of the obtained coatings was identified using X-ray photoelectron spectroscopy and Fourier transform infrared spectroscopy. It is shown that varying the discharge current and hexamethyldisiloxane flow rate in this system produces a wide range of coatings of different chemical constitution. Four different types of coatings obtained were identified: polymethylsiloxane-like structure cross-linked with aliphatic hydrocarbon links with high (C/Si = 9.4) and low (C/Si = 2.9) hydrocarbon linkages, polyhedral oligomeric silsesquioxanes cross-linked with carbosilane, siloxane and aliphatic links with high (C/Si = 5.1) and low (C/Si = 1.5) hydrocarbon linkages. A significant effect of hexamethyldisiloxane flow rate on the chemical structure was found. The most interesting feature of some of the obtained organosilicon coatings is the high relative carbon content. The amount of hydrocarbon links in the coating was found to increase with discharge current. The assumption of formation of hydrocarbon film-forming particles in the cathode layers of the discharge due to ion-induced processes is put forward.
- 1 May 2020
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 14 (3) , 516-524
Effect of Carbon-Ion Implantation on the Surface Physical and Chemical Properties of Polylactic Acid, Hydroxyapatite and a Composite Based on Them
The results of investigation of the surface physical and chemical properties of polylactic acid, hydroxyapatite and a composite material based on them taken in the ratio of components 80/20, modified by carbon ions with exposure doses of 1 × 1015 and 1 × 1016 ion/cm2 at an accelerating voltage of 20 kV are presented. The surface chemical composition of the samples is studied by Fourier transform infrared spectroscopy. The elemental composition of the surface is studied by X-ray photoelectron spectroscopy. According to the obtained results, the simultaneous processes of destruction and cross linking of polylactic acid and polymer macromolecules are established. To assess the wettability of the untreated and modified surface of materials, contact-angle measurements and surface energy calculations are performed. It is established that carbon-ion implantation leads to improvement in the hydrophobic properties of materials; this process is accompanied by a decrease in the free surface energy.
- 1 May 2020
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 14 (3) , 516-524
Effect of Carbon-Ion Implantation on the Surface Physical and Chemical Properties of Polylactic Acid, Hydroxyapatite and a Composite Based on Them
The results of investigation of the surface physical and chemical properties of polylactic acid, hydroxyapatite and a composite material based on them taken in the ratio of components 80/20, modified by carbon ions with exposure doses of 1 × 1015 and 1 × 1016 ion/cm2 at an accelerating voltage of 20 kV are presented. The surface chemical composition of the samples is studied by Fourier transform infrared spectroscopy. The elemental composition of the surface is studied by X-ray photoelectron spectroscopy. According to the obtained results, the simultaneous processes of destruction and cross linking of polylactic acid and polymer macromolecules are established. To assess the wettability of the untreated and modified surface of materials, contact-angle measurements and surface energy calculations are performed. It is established that carbon-ion implantation leads to improvement in the hydrophobic properties of materials; this process is accompanied by a decrease in the free surface energy.
- 1 May 2020
- Published by Elsevier in Surface and Coatings Technology
- Vol. 389
Chemical state and morphology of Zn and Mg ion-implanted polyvinyl alcohol
- 1 May 2020
- Published by Elsevier in Surface and Coatings Technology
- Vol. 389
Chemical state and morphology of Zn and Mg ion-implanted polyvinyl alcohol
- 1 April 2020
- Published by Elsevier in Surface and Coatings Technology
- Vol. 388
Surface property modification of biocompatible material based on polylactic acid by ion implantation
- 1 April 2020
- Published by Elsevier in Surface and Coatings Technology
- Vol. 388
Surface property modification of biocompatible material based on polylactic acid by ion implantation