HNHassan Nahas

Hassan Nahas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hassan Nahas has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    SUP-Net: Slow-Time Upsampling Network for Aliasing Removal in Doppler Ultrasound

    by Hassan Nahas, Alfred C. H. Yu

    Doppler ultrasound modalities, which include spectral Doppler and color flow imaging, are frequently used tools for flow diagnostics because of their real-time point-of-care applicability and high temporal resolution. When implemented using pulse-echo sensing and phase shift estimation principles, this modality’s pulse repetition frequency (PRF) is known to influence the maximum detectable velocity. If the PRF is inevitably set below the Nyquist limit due to imaging requirements or hardware constraints, aliasing errors or spectral overlap may corrupt the estimated flow data. To solve this issue, we have devised a deep learning-based framework, powered by a custom slow-time upsampling network (SUP-Net) that leverages spatiotemporal characteristics to upsample the received ultrasound signals across pulse echoes acquired using high-frame-rate ultrasound (HiFRUS). Our framework infers high-PRF signals from signals acquired at low PRF, thereby improving Doppler ultrasound’s flow estimation quality. SUP-Net was trained and evaluated on in vivo femoral acquisitions from 20 participants and was applied recursively to resolve scenarios with excessive aliasing across a range of PRFs. We report the successful reconstruction of slow-time signals with frequency content that exceeds the Nyquist limit once and twice. By operating on the fundamental slow-time signals, our framework can resolve aliasing-related artifacts in several downstream modalities, including color Doppler and pulse wave Doppler.


  • Open Access

    Bedside Ultrasound Vector Doppler Imaging System With GPU Processing and Deep Learning

    by Hassan Nahas, Billy Y. S. Yiu, Adrian J. Y. Chee, Takuro Ishii, Alfred C. H. Yu

    Recent innovations in vector flow imaging promise to bring the modality closer to clinical application and allow for more comprehensive high-frame-rate vascular assessments. One such innovation is plane-wave multi-angle vector Doppler, where pulsed Doppler principles from multiple steering angles are used to realize vector flow imaging at frame rates upward of 1,000 frames per second (fps). Currently, vector Doppler is limited by the presence of aliasing artifacts that have prevented its reliable realization at the bedside. In this work, we present a new aliasing-resistant vector Doppler imaging system that can be deployed at the bedside using a programmable ultrasound core, graphics processing unit (GPU) processing, and deep learning principles. The framework supports two operational modes: 1) live imaging at 17 fps where vector flow imaging serves to guide image view navigation in blood vessels with complex dynamics; 2) on-demand replay mode where flow data acquired at high frame rates of over 1,000 fps is depicted as a slow-motion playback at 60 fps using an aliasing-resistant vector projectile visualization. Using our new system, aliasing-free vector flow cineloops were successfully obtained in a stenosis phantom experiment and in human bifurcation imaging scans. This system represents a major engineering advance towards the clinical adoption of vector flow imaging.


  • Open Access

    A GPU-Based, Real-Time Dealiasing Framework for High-Frame-Rate Vector Doppler Imaging

    by Hassan Nahas, Takuro Ishii, Billy Y. S. Yiu, Alfred C. H. Yu

    Vector Doppler is well regarded as a potential way of deriving flow vectors to intuitively visualize complex flow profiles, especially when it is implemented at high frame rates. However, this technique’s performance is known to suffer from aliasing artifacts. There is a dire need to devise real-time dealiasing solutions for vector Doppler. In this paper, we present a new methodological framework for achieving aliasing-resistant flow vector estimation at real-time throughput from precalculated Doppler frequencies. Our framework comprises a series of compute kernels that have synergized: 1) an extended least squares vector Doppler (ELS-VD) algorithm, 2) single-instruction, multiple-thread (SIMT) processing principles, and 3) implementation on a graphical processing unit (GPU). Results show that this new framework, when executed on an RTX-2080 GPU, can effectively generate aliasing-free flow vector maps using high-frame-rate imaging datasets acquired from multiple transmit-receive angle pairs in a carotid phantom imaging scenario. Over the entire cardiac cycle, the frame processing time for aliasing-resistant vector estimation was measured to be less than 16 ms, which corresponds to a minimum processing throughput of 62.5 fps. In a human femoral bifurcation imaging trial with fast flow (150 cm/s), our framework was found to be effective in resolving two-cycle aliasing artifacts at a minimum throughput of 53 fps. The framework’s processing throughput was generally in the real-time range for practical combinations of ELS-VD algorithmic parameters. Overall, this work represents the first demonstration of real-time, GPU-based aliasing-resistant vector flow imaging using vector Doppler estimation principles.


  • Open Access

    Artificial-Intelligence-Enhanced Ultrasound Flow Imaging at the Edge

    by Hassan Nahas, Sean Huver, Billy Y. S. Yiu, Chris M. Kallweit, Adrian J. Y. Chee, Alfred C. H. Yu

    Ultrasound flow imaging has long been used for cardiovascular diagnostics. Color Doppler imaging (CDI) is the predominant ultrasound flow imaging mode, but its diagnostic value is hampered by aliasing artifacts that limit the range of detectable blood velocities. Here, we present the first demonstration of how edge artificial intelligence (AI) can enable real-time CDI with aliasing resistance. Specifically, graphical processing unit (GPU) acceleration and AI-ready edge computing hardware have been leveraged to realize the first end-to-end CDI processing pipeline that involves AI-based aliasing correction. Performance results show that, using our edge AI engine, aliasing-resistant CDI frames with threefold velocity detection range can be generated at a real-time frame rate of 25 fps (for raw datasets with 192 channels, 12-bit data resolution, and 25 MHz sampling rate). Overall, edge AI can critically improve the real-time visualization quality of ultrasound flow imaging and, in turn, potentially transform its bedside application value.


  • Open Access

    A Deep Learning Approach to Resolve Aliasing Artifacts in Ultrasound Color Flow Imaging

    by Hassan Nahas, Jason S. Au, Takuro Ishii, Billy Y. S. Yiu, Adrian J. Y. Chee, Alfred C. H. Yu

    Despite being used clinically as a non-invasive flow visualization tool, color flow imaging (CFI) is known to be prone to aliasing artifacts that arise due to fast blood flow beyond the detectable limit. From a visualization standpoint, these aliasing artifacts obscure proper interpretation of flow patterns in the image view. Current solutions for resolving aliasing artifacts are typically not robust against issues such as double aliasing. In this paper, we present a new dealiasing technique based on deep learning principles to resolve CFI aliasing artifacts that arise from single and double aliasing scenarios. It works by first using two convolutional neural networks (CNNs) to identify and segment CFI pixel positions with aliasing artifacts, and then it performs phase unwrapping at these aliased pixel positions. The CNN for aliasing identification is devised as a U-net architecture, and it was trained with in vivo CFI frames acquired from the femoral bifurcation that had known presence of single and double aliasing artifacts. Results show that segmentation of aliased CFI pixels was achieved successfully with intersection-over-union approaching 90%. After resolving these artifacts, the dealiased CFI frames consistently rendered the femoral bifurcation’s triphasic flow dynamics over a cardiac cycle. For dealiased CFI pixels, their rootmean- squared difference was 2.51% or less comparing to manual dealiasing. Overall, the proposed dealiasing framework can extend the maximum flow detection limit by fivefold, thereby improving CFI’s flow visualization performance.