YJYang Ji

Yang Ji

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yang Ji has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Parallel Wires: A Conserved Principle of Contralateral-Ipsilateral Segregation in the Visual Corpus Callosum

    by Jiaowen Wang, Yanming Wang, Yiping An, Shishuo Chen, Benedictor Alexander Nguchu, Huan Wang, Muhammad Mohsin Pathan, Yueyi Yu, Sinan Yang, Ying-Qiu Zheng, et al.

    How the brain maintains distinct information streams within dense white matter is a fundamental question. We investigated whether the visual corpus callosum transmits information via segregated “parallel wires” or mixed pathways. This distinction is critical: a mixed architecture would render the signal’s origin ambiguous, whereas a segregated arrangement implies that spatial position tracks the direction of information flow. Using high-field fMRI and Bayesian modeling in humans, we demonstrate a segregated architecture featuring distinct contralateral and ipsilateral channels. This functional segregation mirrors a precise anatomical arrangement in mice, where dual-color viral tracing and light-sheet microscopy reveal that callosal axons remain spatially segregated in distinct laminae after crossing the midline. Our findings establish a conserved “parallel wires” principle of callosal organization, providing a new framework to decode directional information flow and assess pathway-specific damage in neurological disease.

  • Open Access

    Parallel Wires: A Conserved Principle of Contralateral-Ipsilateral Segregation in the Visual Corpus Callosum

    by Jiaowen Wang, Yanming Wang, Yiping An, Shishuo Chen, Benedictor Alexander Nguchu, Huan Wang, Muhammad Mohsin Pathan, Yueyi Yu, Sinan Yang, Ying-Qiu Zheng, et al.

    How the brain maintains distinct information streams within dense white matter is a fundamental question. We investigated whether the visual corpus callosum transmits information via segregated “parallel wires” or mixed pathways. This distinction is critical: a mixed architecture would render the signal’s origin ambiguous, whereas a segregated arrangement implies that spatial position tracks the direction of information flow. Using high-field fMRI and Bayesian modeling in humans, we demonstrate a segregated architecture featuring distinct contralateral and ipsilateral channels. This functional segregation mirrors a precise anatomical arrangement in mice, where dual-color viral tracing and light-sheet microscopy reveal that callosal axons remain spatially segregated in distinct laminae after crossing the midline. Our findings establish a conserved “parallel wires” principle of callosal organization, providing a new framework to decode directional information flow and assess pathway-specific damage in neurological disease.

  • Open Access

    Achieving robust labeling above the circle of Willis with vessel‐encoded arterial spin labeling

    by Hongwei Li, Yang Ji, He Wang, Zhensen Chen, Tiansheng Qian, Yujun Liao, Jian Wang, Joseph G. Woods, Yuriko Suzuki, Thomas W. Okell

    Purpose: To improve the robustness of noninvasive vessel‐selective perfusion imaging and angiography using vessel‐encoded arterial spin labeling (VEASL) when applied to complex vascular geometries, such as above the circle of Willis (CoW) in the brain. Methods: Our proposed improved optimized encoding scheme (IOES) better accounts for vascular geometry and the VEASL encoding process, leading to more SNR‐efficient encodings than previous approaches. Pseudo‐continuous arterial spin labeling (PCASL) parameters were optimized for a thinner labeling region, allowing tortuous vessels to be more accurately treated as single points within the labeling plane. Our optimized approach was compared to the original OES method above the CoW in healthy volunteers, with preliminary application in two Moyamoya patients. Results: In simulation, the IOES improved SNR efficiency by approximately 10% and used longer wavelength encodings that are less sensitive to subject motion. The effective labeling thickness was reduced using optimized PCASL parameters, which maintained high labeling efficiency. In healthy volunteers, these improvements allowed for the separation of at least nine arteries and their downstream tissues, with more accurate vessel decoding and closer alignment between the measured VEASL signal modulation and the encoding design. Vascular territories consistent with angiography were found in the Moyamoya patients. Conclusions: Combining IOES with optimized PCASL parameters, the vessel‐decoding efficacy in a region with complex vascular geometry above the CoW was improved. The automated encoding design process and scan times under 6 min make it feasible to observe flow patterns above the CoW in clinical settings, particularly for studies of collateral circulation.


  • Open Access

    SNR‐efficient whole‐brain pseudo‐continuous arterial spin labeling perfusion imaging at 7 T

    by Joseph G. Woods, Yang Ji, Hongwei Li, Aaron T. Hess, Thomas W. Okell

    Purpose: To optimize pseudo‐continuous arterial spin labeling (PCASL) parameters to maximize SNR efficiency for RF power constrained whole brain perfusion imaging at 7 T.Methods: We used Bloch simulations of pulsatile laminar flow to optimize the PCASL parameters for maximum SNR efficiency, balancing labeling efficiency and total RF power. The optimization included adjusting the inter‐RF pulse spacing (TRPCASL), mean B1+ (B1+ave), slice‐selective gradient amplitude (Gmax), and mean gradient amplitude (Gave). In vivo data were acquired from six volunteers at 7 T to validate the optimized parameters. Dynamic B0‐shimming and flip angle adjustments were used to avoid needing to make the PCASL parameters robust to B0/B1+ variations.Results: The optimized PCASL parameters achieved a significant (3.3×) reduction in RF power while maintaining high labeling efficiency. This allowed for longer label durations and minimized deadtime, resulting in a 118% improvement in SNR efficiency in vivo compared to a previously proposed protocol. Additionally, the static tissue response was improved, reducing the required distance between labeling plane and imaging volume.Conclusion: These optimized PCASL parameters provide a robust and efficient approach for whole brain perfusion imaging at 7 T, with significant improvements in SNR efficiency and reduced specific absorption rate burden.


  • Open Access

    Ultra‐high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction

    by Qijia Shen, Wenchuan Wu, Mark Chiew, Yang Ji, Joseph G. Woods, Thomas W. Okell

    Purpose: To achieve ultra‐high temporal resolution non‐contrast 4D angiography with improved spatiotemporal fidelity.Methods: Continuous data acquisition using 3D golden‐angle sampling following an arterial spin labeling preparation allows for flexibly reconstructing 4D dynamic angiograms at arbitrary temporal resolutions. However, k‐space data is often temporally “binned” before image reconstruction, negatively affecting spatiotemporal fidelity and limiting temporal resolution. In this work, a subspace was extracted by linearly compressing a dictionary constructed from simulated curves of an angiographic kinetic model. The subspace was used to represent and reconstruct the voxelwise signal timecourse at the same temporal resolution as the data acquisition without temporal binning. Physiological parameters were estimated from the resulting images using a Bayesian fitting approach. A group of eight healthy subjects were scanned and the in vivo results reconstructed by different methods were compared. Because of the difficulty of obtaining ground truth 4D angiograms with ultra‐high temporal resolution, the in vivo results were cross‐validated with numerical simulations.Results: The proposed method enables 4D time‐resolved angiography with much higher temporal resolution (14.7 ms) than previously reported (˜50 ms) while maintaining high spatial resolution (1.1 mm isotropic). Blood flow dynamics were depicted in greater detail, thin vessel visibility was improved, and the estimated physiological parameters also exhibited more realistic spatial patterns with the proposed method.Conclusion: Incorporating a subspace compressed kinetic model into the reconstruction of 4D ASL angiograms notably improved the temporal resolution and spatiotemporal fidelity, which was subsequently beneficial for accurate physiological modeling.


  • Open Access

    Dynamic B 0 field shimming for improving pseudo‐continuous arterial spin labeling at 7 T

    by Yang Ji, Joseph G. Woods, Hongwei Li, Thomas W. Okell

    Purpose: B 0 field inhomogeneity within the brain‐feeding arteries is a major issue for pseudo‐continuous arterial spin labeling (PCASL) at 7 T because it reduces the labeling efficiency and leads to a loss of perfusion signal. This study aimed to develop a vessel‐specific dynamic B 0 field shimming method for 7 T PCASL to improve the labeling efficiency by correcting off‐resonance within the arteries in the labeling region. Methods: We implemented a PCASL sequence with dynamic B 0 shimming at 7 T that compensates for B 0 field offsets in the brain‐feeding arteries by updating linear shimming terms and adding a phase increment to the PCASL RF pulses. Rapidly acquired vessel‐specific B 0 field maps were used to calculate dynamic B 0 shimming parameters. We evaluated both 2D and 3D variants of our method, comparing their performance against the established global frequency offset and optimal encoding scheme‐based corrections. Cerebral blood flow (CBF) maps were quantified before and after corrections, and CBF values from different methods were compared across the whole brain, white matter, and gray matter regions. Results: All off‐resonance correction methods significantly recovered perfusion signals across the brain. The proposed vessel‐specific dynamic B 0 shimming method improved the labeling efficiency while maintaining optimal static shimming in the imaging region. Perfusion‐weighted images demonstrated the superiority of the 3D dynamic B 0 shimming method compared to global or 2D‐based correction approaches. CBF analysis revealed that 3D dynamic B 0 shimming significantly increased CBF values relative to the other methods. Conclusion: Our proposed dynamic B 0 shimming method offers a significant advancement in PCASL robustness and effectiveness, enabling full utilization of 7 T ASL high sensitivity and spatial resolution.


  • Open Access

    SNR-Efficient Whole-Brain Pseudo-Continuous Arterial Spin Labeling Perfusion Imaging at 7 Tesla

    by Joseph G. Woods, Yang Ji, Hongwei Li, Aaron T. Hess, Thomas W. Okell

    Purpose: To optimize pseudo-continuous arterial spin labeling (PCASL) parameters to maximize SNR efficiency for RF power constrained whole brain perfusion imaging at 7 T. Methods: We used Bloch simulations of pulsatile laminar flow to optimize the PCASL parameters for maximum SNR efficiency, balancing labeling efficiency and total RF power. The optimization included adjusting the inter-RF pulse spacing (TR PCASL ), mean B 1 + (B 1 ave ), slice-selective gradient amplitude (G max ), and mean gradient amplitude (G ave ). In vivo data were acquired from four volunteers at 7 T to validate the optimized parameters. Dynamic B 0 -shimming and flip angle adjustments were utilized to avoid needing to make the PCASL parameters robust to B 0 /B 1 + variations. Results: The optimized PCASL parameters achieved a significant (3.1x) reduction in RF power while maintaining high labeling efficiency. This allowed for longer label durations and minimized deadtime, and resulted in a 126% improvement in SNR efficiency in vivo compared to a previously proposed protocol. Additionally, the static tissue response was improved, reducing the required distance between labeling plane and imaging volume. Conclusion: These optimized PCASL parameters provide a robust and efficient approach for whole brain perfusion imaging at 7 T, with significant improvements in SNR efficiency and reduced SAR burden.


  • Improving standardization and accuracy of in vivo omega plot exchange parameter determination using rotating‐frame model‐based fitting of quasi‐steady‐state Z‐spectra

    by Julius Juhyun Chung, Hahnsung Kim, Yang Ji, Dongshuang Lu, Iris Y. Zhou, Phillip Zhe Sun

    Purpose: Although Ω‐plot‐driven quantification of in vivo amide exchange properties has been demonstrated, differences in scan parameters may complicate the fidelity of determination. This work systematically evaluated the use of quasi‐steady‐state (QUASS) Z‐spectra reconstruction to standardize in vivo amide exchange quantification across acquisition conditions and further determined it in vivo.Methods: Simulation and in vivo rodent brain chemical exchange saturation transfer (CEST) data at 4.7 T were fit with and without QUASS reconstruction using both multi‐Lorentzian and model‐based fitting approaches. pH modulation was accomplished both in simulation and in vivo by inducing global ischemia via cardiac arrest. Amide parameters were determined via Ω‐plots and compared across methods.Results: Simulation showed that Ω‐plots using multi‐Lorentzian fitting could underestimate the exchange rate, with error increasing as conditions diverged from the steady state. In comparison, model‐based fitting using QUASS estimated the same exchange rate within 2%. These results aligned with in vivo findings where multi‐Lorentzian fitting of native Z‐spectra resulted in an exchange rate of 64 ± 13 s−1 (38 ± 16 s−1 after cardiac arrest), whereas model‐based fitting of QUASS Z‐spectra yielded an exchange rate of 126 ± 25 s−1 (49 ± 13 s−1).Conclusion: The model‐based fitting of QUASS CEST Z‐spectra enables consistent and accurate quantification of exchange parameters through Ω‐plot construction by reducing error due to signal overlap and nonequilibrium CEST effects.


  • Open Access

    Motion correction with subspace-based self-navigation for combined angiography, perfusion and structural imaging

    by Qijia Shen, Wenchuan Wu, Mark Chiew, Yang Ji, Joseph G. Woods, Thomas W. Okell

    Motion artifacts are problematic in many MRI modalities. “Self-navigating” approaches are desirable, since no additional scan time or hardware is required. However, the generation of a navigator image, to estimate and correct motion, is difficult in cases where the tissue contrast is changing during the navigator acquisition window, such as in magnetization- prepared methods. Here we propose a subspace approach to reconstruct accurate navigators in the presence of time-varying tissue contrast and apply it to a combined angiography, perfusion and structural imaging method using a golden ratio 3D cones trajectory. This arterial spin labeling-based pulse sequence relies on subtraction of label and control images to isolate the relatively weak blood signal, making it particularly susceptible to motion corruption. An inversion pulse leads to time-varying tissue contrast across the readout train, but by reconstructing subspace coefficient maps directly, artifacts due to the varying contrast were alleviated. This resulted in high-quality navigator images that were subsequently registered to estimate and correct for motion. In addition, a split-update method was proposed to efficiently reconstruct from mismatched label/control k-space data with locally low rank regularization enforced on the difference image. The correction process was tested with numerical simulation and in vivo data from 8 healthy subjects with and without cued motion. In numerical simulation, the subspace- based navigator achieved an 84% reduction in RMSE of residual motion compared to without motion correction. In vivo, motion correction resulted in noise-like and background artifacts being greatly reduced and vessel sharpness being noticeably improved. Correlation of angiography, perfusion and structural images with motion-free reference images also increased by 159%, 53% and 12%, respectively, after motion correction. These results show that subspace-based navigators can effectively improve the motion robustness of MR imaging in contrast-varying acquisitions.