Wei Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei Zhou has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Long Wei
Chinese Academy of Sciences
6 shared publications - Mingjie Yang
Key Laboratory of Particle Astrophysics & Experimental Physics Division & Computing Center, Institute of High Energy Physics, Chinese Academy of Sciences, 19B Yuquan Road, Beijing, 100049, China
4 shared publications - Yingjie Wang
Beijing Engineering Research Center of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
4 shared publications - Pei Chai
State Grid Shandong Electric Power Construction Company, Jinan City, Shandong Province, China
3 shared publications - Yantao Liu
Chinese Academy of Sciences
3 shared publications Xian-Chao Huang
Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
2 shared publications
Latest Publications
- 1 July 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (07) , P07023
Comparative study of the gamma-ray response of liquid scintillators developed for neutrino experiments and EJ-309
A comparative study of the gamma-ray response of Daya Bay gadolinium-loaded liquid scintillator (Gd-LS), JUNO liquid scintillator (LS), and the commercial reference scintillator EJ-309 was carried out using a compact 2-inch photomultiplier-tube-based detector system. Measurements were performed under identical conditions with 137Cs, 22Na, and 241Am radioactive sources. The measured spectra are dominated by Compton continua, and the Compton-edge positions were extracted from the smoothed spectra using a first-derivative method. Based on the 137Cs spectra, the relative light yields of Daya Bay Gd-LS and JUNO LS were determined to be (60.7 ± 0.2)% and (63.7 ± 0.2)% of that of EJ-309 LS, respectively, where the uncertainty reflects the variation associated with the Compton-edge extraction. Energy calibration based on the extracted Compton-edge positions shows approximately linear energy-ADC relationships for the three scintillators under the present detector and readout configuration. Although the LAB-based scintillators provide lower light output than EJ-309 LS, they show stable gamma-ray response in the present compact detector system and may serve as useful candidates for further radiation-detection studies beyond large-volume neutrino experiments.
- 1 July 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (07) , P07023
Comparative study of the gamma-ray response of liquid scintillators developed for neutrino experiments and EJ-309
A comparative study of the gamma-ray response of Daya Bay gadolinium-loaded liquid scintillator (Gd-LS), JUNO liquid scintillator (LS), and the commercial reference scintillator EJ-309 was carried out using a compact 2-inch photomultiplier-tube-based detector system. Measurements were performed under identical conditions with 137Cs, 22Na, and 241Am radioactive sources. The measured spectra are dominated by Compton continua, and the Compton-edge positions were extracted from the smoothed spectra using a first-derivative method. Based on the 137Cs spectra, the relative light yields of Daya Bay Gd-LS and JUNO LS were determined to be (60.7 ± 0.2)% and (63.7 ± 0.2)% of that of EJ-309 LS, respectively, where the uncertainty reflects the variation associated with the Compton-edge extraction. Energy calibration based on the extracted Compton-edge positions shows approximately linear energy-ADC relationships for the three scintillators under the present detector and readout configuration. Although the LAB-based scintillators provide lower light output than EJ-309 LS, they show stable gamma-ray response in the present compact detector system and may serve as useful candidates for further radiation-detection studies beyond large-volume neutrino experiments.
- 1 November 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 113308
An instrument for measuring scintillators efficiently based on silicon photomultipliers
An instrument used for measuring multiple scintillators’ light output and energy resolution was developed. The instrument consisted of a light sensor array which was composed of 64 discrete SiPMs (Silicon Photomultipliers), a corresponding individual channel readout electronics system, and a data processing algorithm. A Teflon grid and a large interval between adjacent SiPMs were employed to eliminate the optical cross talk among scintillators. The scintillators’ light output was obtained by comparing with a reference sample with known light output. Given the SiPM temperature dependency and the difference among each SiPM, a temperature offset correction algorithm and a non-uniformity correction algorithm were added to the instrument. A positioning algorithm, based on nine points, was designed to evaluate the performance of a scintillator array. Tests were performed to evaluate the instrument’s performance. The uniformity of 64 channels for light output measurement was better than 98%, the stability was better than 98% when temperature varied from 15 °C to 40 °C, and the nonlinearity under 511 keV was better than 2%. This instrument was capable of selecting scintillators and evaluating the packaging technology of scintillator arrays with high efficiency and accuracy.
- 1 November 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 113308
An instrument for measuring scintillators efficiently based on silicon photomultipliers
An instrument used for measuring multiple scintillators’ light output and energy resolution was developed. The instrument consisted of a light sensor array which was composed of 64 discrete SiPMs (Silicon Photomultipliers), a corresponding individual channel readout electronics system, and a data processing algorithm. A Teflon grid and a large interval between adjacent SiPMs were employed to eliminate the optical cross talk among scintillators. The scintillators’ light output was obtained by comparing with a reference sample with known light output. Given the SiPM temperature dependency and the difference among each SiPM, a temperature offset correction algorithm and a non-uniformity correction algorithm were added to the instrument. A positioning algorithm, based on nine points, was designed to evaluate the performance of a scintillator array. Tests were performed to evaluate the instrument’s performance. The uniformity of 64 channels for light output measurement was better than 98%, the stability was better than 98% when temperature varied from 15 °C to 40 °C, and the nonlinearity under 511 keV was better than 2%. This instrument was capable of selecting scintillators and evaluating the packaging technology of scintillator arrays with high efficiency and accuracy.
- 31 August 2016
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 27 (5) , 119
A QTC-based signal readout for position-sensitive multi-output detectors
- 31 August 2016
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 27 (5) , 119
A QTC-based signal readout for position-sensitive multi-output detectors
- 1 May 2016
- Published by IOP Publishing in Chinese Physics C
- Vol. 40 (5) , 058201
High resolution image reconstruction method for a double-plane PET system with changeable spacing
- 1 May 2016
- Published by IOP Publishing in Chinese Physics C
- Vol. 40 (5) , 058201
High resolution image reconstruction method for a double-plane PET system with changeable spacing
- 1 January 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 107, 177-182
Far field 3D localization of radioactive hot spots using a coded aperture camera
- 1 January 2016
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 107, 177-182
Far field 3D localization of radioactive hot spots using a coded aperture camera
- 1 June 2015
- Published by Elsevier in Radiation Measurements
- Vol. 77, 34-40
Development of a panorama coded-aperture gamma camera for radiation detection
- 1 June 2015
- Published by Elsevier in Radiation Measurements
- Vol. 77, 34-40
Development of a panorama coded-aperture gamma camera for radiation detection