MYMingjie Yang

Mingjie Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mingjie Yang has a total of 343 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Performance of LACT SiPM camera front-end electronics

    by Kefan Li, Huimin Yang, Mingjie Yang, Maomao Ge, Shoushan Zhang, Ming Wei, Qinyuan Zhao, Fengrong Zhu

    The Large Array of Imaging Atmospheric Cherenkov Telescope (LACT) will be constructed at the Large High Altitude Air Shower Observatory (LHAASO). It will collaborate with the LHAASO muon detector array to achieve observations of the fine structure of ultra-high energy gamma-ray sources. The camera employs an imaging technique to accurately measure and document the intensity and form of the atmospheric Cherenkov light as it reaches the telescope's focal plane. The LACT camera will utilize large-area silicon photomultiplier (SiPMs) as the photodetectors. The presence of quenching resistors and terminal capacitance lead to a longer recovery time for the avalanche discharge of SiPMs. As the area of the SiPM increases, the output pulse fall time becomes longer. This paper presents various design strategies for low-power, narrow pulse shaping circuits tailored for large-area SiPMs, and it offers a comprehensive comparative analysis of these circuit designs in relation to the LACT camera's design specifications.

  • Design and Development of an Automated Operation Program for LHAASO-WFCTA

    by Junxian Yang, Zhen Min, Yudong Wang, Shoushan Zhang, Mingjie Yang, Yong Zhang, Zhiyong You, Lisi Geng, Jinglong Zhang

    The Wide Field Cherenkov Telescope Array (WFCTA) is an essential component of the Large High Altitude Air Shower Observatory (LHAASO), consisting of 18 imaging Atmospheric Cherenkov telescopes. Each telescope is composed of multiple subsystems, featuring high integration and complexity. During observations, the operators need to control the corresponding equipment, monitor its status, and simultaneously judge the weather conditions at the site. The operation involves multiple devices and lengthy procedures, requiring collaboration among several operators. To enhance the observation efficiency of the WFCTA, we designed and developed the Cherenkov Telescope Automated Operation Meteorological Monitoring System Based On Cloud Data (CAMC) and an automated operation program. This program enables real-time collection of various status information from the telescopes and automatically controls the telescopes according to the observation process. The application of this program not only simplifies the operation of the telescopes and reduces the involvement of operators but also facilitates timely detection and handling of equipment malfunctions, while improving the timeliness and accuracy of weather judgment.

  • The cooling design scheme for the SiPM camera of the LACT experiment

    by Ming Wei, Mingjie Yang, Shoushan Zhang, Lisi Geng, Changge Zi, Jinfan Chang, Zhen Min, Maoyuan Liu

    The LACT experiment will construct 32 six-meter aperture imaging atmospheric Cherenkov telescopes at the LHAASO site for in-depth observation of the ultra-high-energy gamma-ray sources discovered by the LHAASO experiment. The telescope mainly consists of three parts: a support and rotation system, a reflector, and a silicon photomultiplier (SiPM) camera. The SiPM camera is composed of 1616 SiPM sensors connected to 1616 channels of readout electronics. This paper reports on a cooling scheme suitable for the SiPM camera's all-sky rotational working posture in a high-altitude environment, and the effectiveness of the cooling system is verified through thermal simulations and laboratory measurements.


  • Ultrasonic Driving Power Based on Resonance Frequency Tracking Method with Variable Step Size

    by Mingjie Yang, Dongdong Chen, Long Xiao

    In the ultrasonic driving power system for ultrasonic cleaning, the natural resonance frequency will drift as the depth in water variation of the piezoelectric transducer. Then, the efficiency of the power supply will decrease because of the detuning state. To solve this detuning problem, a resonance frequency tracking method with variable step size is adopted in this paper. By measuring the output current from full bridge inverter and DC source, and adjusting the output frequency of the power supply with variable step size, the current ratio between them is minimized, which makes the power return to resonant state and improves its efficiency. Finally, the series resonant frequency tracking experiments are carried out against different depths in water of piezoelectric transducer by a prototype setup. The test results show that the power can track the series resonant frequency effectively with different depths in water by the proposed method. Moreover, the efficiency of the overall power increases up to 14.06%.

  • A Modified Multi-objective FCS-MPC for the IPMSM with MTPA Operation

    by Aiyu Gu, Xijun Liu, Dengshu Zhang, Mingjie Yang

    In this paper, a modified control strategy of Finite-Control-Set Model Predictive Control (FCS-MPC) for the Interior Permanent Magnet Synchronous Motor (IPMSM) is proposed to solve the problem that the actual stator current cannot quickly track the given Maximum Torque Per Ampere (MTPA) current due to the integration saturation of the current regulator caused by sudden changes in load torque. The FCS-MPC controller is used to replace the PI current regulator, to obtain a more accurate voltage vector and achieve real-time dynamic tracking of the IPMSM MTPA target trajectory. The cost function of FCS-MPC control strategy is designed multi-objective combination to meet such requirements: torque tracking, MTPA current tracking and limitation of the maximum current. The simulation and experimental results show that the proposed control strategy can track the MTPA given current and torque in real time during load torque sudden changes.


  • Open Access

    Novel compact high-speed passive gamma-ray assay equipment for uranium enrichment measurement of fuel rods

    by Yantao Liu, Shuangquan Liu, Cunfeng Wei, Dongbao Yu, Peiling Wang, Xiaoming Wang, Yingjie Wang, Mingjie Yang, Jing Guo, Zhiming Zhang, et al.

    Uranium enrichment measurement is an essential quality inspection for fuel rods before delivery to users. Generally, compared with active neutron assay (ANA) equipment, passive gamma-ray assay (PGA) equipment is more economical and safer. However, the current PGA equipment based on photomultipliers is too slow (1 m/min) to meet the growing needs in China. Recently, we have developed a set of compact high-speed PGA equipment including four detection modules (128 units in total), a 128-channel data acquisition system (DAS), a power supply, special software, and an automatic loading and unloading mechanism. The detection unit is based on silicon photomultipliers in virtue of its compact size and good performance. The DAS processes signals of all units in parallel into a sequence of data packets carrying the energy information and the corresponding unit ID. The software integrates the data packets into a fluctuating count curve in a time-delay superposition method and identifies possible abnormal pellets. After calibrations, our equipment can locate abnormal pellets accurately at a speed of 6 m/min. In addition, it can directly measure the enrichment of fresh pellets not in secular equilibrium without waiting for two months. So far, the equipment has been successfully run for one year on the assembly line of China North Nuclear Fuel Co. and shows good potential to replace the traditional ANA equipment.


  • A scintillating plastic fiber array and multiplexer based 384-channel fast neutron spectrometer

    by Liyang Sun, Kai Zhuang, Xiaoming Wang, Heng An, Fanjian Zeng, Mingjie Yang, Wei Zhou, YuXiong Xue, Zhiming Zhang, Yingjie Wang, et al.

    A fast neutron detection system based on a scintillating plastic fiber array and multiplexer was designed to measure the spectrum of fast neutrons ranged 10 MeV–100 MeV. With the method of nuclear recoil, the energy of incident neutron was determined by measuring the recoil proton track and deposited energy in scintillating plastic fibers. The detection system was composed of a scintillating plastic fiber array, 6 position sensitive photomultiplier tubes, and a high-density readout electronics based on the multiplexer. The scintillating plastic fiber array was made as a staggered structure with two kinds of fibers in different sizes (0.5 mm-square fiber and 3 mm-square fiber). The structure provided a wider detection energy range and better detection efficiency than arrays made with uniform plastic fibers. A dedicated digital electronics system was well designed to control the whole readout system to provide 384-channel signal processing. The detector had a 48 mm × 48 mm effective detection area and a mechanical size of 34 cm × 34 cm × 27 cm. In the simulation of the detector model performance, the system gave an energy resolution of 23%-35% for neutrons ranged 10 MeV-100 MeV. Experimental results showed that the detector had a good energy linearity and energy resolutions were, respectively, 35.82% at 14.817 MeV, 36.84% at 21.264 MeV, 35.90% at 23.069 MeV, and 32.90% at 24.220 MeV. The optimized prototype model had potential in increasing fast neutron detection performance.


  • An instrument for measuring scintillators efficiently based on silicon photomultipliers

    by M. J. Yang, Z. M. Zhang, Y. J. Wang, D. W. Li, W. Zhou, H. H. Tang, Y. T. Liu, P. Chai, L. Shuai, X. C. Huang, et al.

    An instrument used for measuring multiple scintillators’ light output and energy resolution was developed. The instrument consisted of a light sensor array which was composed of 64 discrete SiPMs (Silicon Photomultipliers), a corresponding individual channel readout electronics system, and a data processing algorithm. A Teflon grid and a large interval between adjacent SiPMs were employed to eliminate the optical cross talk among scintillators. The scintillators’ light output was obtained by comparing with a reference sample with known light output. Given the SiPM temperature dependency and the difference among each SiPM, a temperature offset correction algorithm and a non-uniformity correction algorithm were added to the instrument. A positioning algorithm, based on nine points, was designed to evaluate the performance of a scintillator array. Tests were performed to evaluate the instrument’s performance. The uniformity of 64 channels for light output measurement was better than 98%, the stability was better than 98% when temperature varied from 15 °C to 40 °C, and the nonlinearity under 511 keV was better than 2%. This instrument was capable of selecting scintillators and evaluating the packaging technology of scintillator arrays with high efficiency and accuracy.