OMOleksii Mykhailenko

Oleksii Mykhailenko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oleksii Mykhailenko has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Adaptive control of power receivers supply voltage in underground mines

    by Oleh Sinchuk, Oleksii Mykhailenko, Ihor Sinchuk, Maryna Kotiakova, Vladyslav Baranovskyi, Mila Baranovska

    Purpose. This research aims to synthesize an automated system for stabilising the supply voltage of individual electrical consumers at iron ore mines when it deviates from standardised values due to unpredictable disturbances in the mine power systems. Methods. A dynamic voltage restorer was used to stabilize the supply voltage of mine electrical consumers. The basic control system for the dynamic voltage restorer was developed using control theory methods, such as linear-quadratic control. Heuristic optimization methods were used to adapt the linear-quadratic regulator to unpredictable disturbances. The control integral absolute error was taken as the criterion. Numerical analysis was used to check the quality of transients during voltage stabilization using the proposed system. Findings. The adaptive control system for a dynamic voltage restorer has been developed to stabilize the supply voltage of individual electrical consumers at iron ore mines. The optimal genetic algorithm parameters have been determined, including the population size and mutation rates of the linear-quadratic regulator weight matrices. It minimizes the integral absolute error and, as a result, eliminates overshoot (overshoot is no more than 0.058%) and reduces the transient time (up to 95%) compared to the unoptimized system. Originality. The method of adaptive automated linear-quadratic regulator tuning based on a genetic algorithm is proposed. For the first time, it is used to control a dynamic voltage restorer installed between the power grid and the mine electrical consumer. This method has enabled the compensation of fluctuations in the mine power grid voltage at the consumer end, without overshoot and with short settling times. Practical implications. The results can be used for the development of digital controllers embedded firmware for dynamic voltage restorers, providing real-time voltage fluctuation compensation and improving the power supply quality to mine electrical consumers.

  • Model-based designof a cone crusher adaptive control system

    by O. Yu Mykhailenko, D. V Tsyplenkov, O. V Ilchenko, H. V Kolomits, V. S Lazariev

    Purpose. The purpose of the article is to develop a methodology for creating cone crusher adaptive control system based on the model-based design method for automated software generation of microprocessor controllers. Methodology. A method based on a block-oriented predictive model was used to generate control signals for the cone crusher. The parameters and structure of this model were identified in real time using measured data from the plant. A prototype of the control system was created in MATLAB/Simulink. Then, the model-based design method was used to generate software for digital signal processors. Mathematical statistics methods were employed to analyze the experimental results. Findings. A method of model-based design of an adaptive control system for a cone crusher has been developed. This system uses a predictive model of a block-oriented structure. This model adjusts the predictive controller’s structure and parameters directly during operation. This approach makes it possible to divide the functions of identifying the process model and generating controls between the two digital controllers. Consequently, the average computational time is reduced while ensuring the stabilization of the degree of homogeneity of ore crushing and separate output of the control size class, with respective standard deviation coefficients not exceeding 3.42 and 1.83 %, respectively. Originality. The regularity of the effect of the closed-side setting and the eccentric speed on the particle size distribution of crushed ore has been established. This shows that high homogeneity of the crushed product is ensured by simultaneously adjusting these input coordinates. We propose a new method for synthesizing an adaptive cone crusher control system based on a model-based design approach. This method provides automated real-time generation of software for microprocessor-based controllers, allowing the system to quickly adjust to changes in rock mass characteristics and other disturbances. Practical value. A hardware and software implementation of an adaptive control system for a cone crusher is proposed. This system is based on a block-oriented predictive model. The model ensures the stabilization of the required ore particle size distribution. This stabilization is achieved by adjusting the closed-side setting and the eccentric speed. The system is based on 16-bit, low-cost digital signal processors. A prototype of the system was tested in a crushing plant at a metallurgical enterprise.

  • Open Access

    Analysis of power quality indicators in the development of a smart grid at an underground mine

    by Oleh M. Sinchuk, Oleksii Yu. Mykhailenko, Ihor O. Sinchuk, Maryna H. Kotiakova

    У роботі показані результати експериментальних досліджень показників якості електроенергії в системіелектропостачання підземного залізорудного рудника при плануванні розробки розумної електромережі. Вимірюванняпроводилися спеціалізованим обладнанням у точках електромережі з рівнями напруги 6 і 0,4 кВ. Проаналізовано ключовіпоказники якості електроенергії, як-то відхилення напруги, сумарний коефіцієнт гармонічних спотворень струму й напруги,а також відхилення частоти. Встановлено, що в мережі 6 кВ падіння напруги знаходиться в межах гранично допустимогорівня (+/-10 %). У частині електромережі з рівнем напруги 0,4 кВ виникають критичні відхилення напруги, які перевищуютьстандартизовану межу. Сумарний коефіцієнт гармонічних спотворень напруги та струму, а також частота тут знаходяться вмежах норми. На основі отриманих даних виявлено системний характер проблем з якістю напруги у віддалених від поверхнівузлах системи електропостачання підземного рудника. Це вимагає потребує виконання детального технічного аудиту станукабельних ліній, трансформаторів, а також оцінки можливості застосування спеціалізованих засобів компенсації падіньнапруги (наприклад, динамічних відновлювачів напруги, статичних компенсаторів тощо). Такі заходи є необхідними длязабезпечення стабільного та надійного електропостачання в умовах розбудови розумної електромережі підземногозалізорудного підприємства, що має ключове значення для забезпечення надійного електропостачання підземнихелектроприймачів та поліпшення конкурентоспроможності гірничорудного виробництва

  • Open Access

    “Smart” power control for receivers up to 1000 V at underground mining enterprises

    by Oleh M. Sinchuk, Oleksii Yu. Mykhailenko, Danyil V. Kobeliatskyi

    У роботі розглядається «розумне» керування електроспоживанням електроприймачів напругою до 1000 В підземногозалізорудного підприємства для оптимізації добових витрат на електроенергію. Актуальність роботу обумовлюєтьсявисоким рівнем енерговитрат на ведення гірничих процесів при підземному способі видобутку залізорудної сировини. Такяк графік роботи електроприймачів до 1000 В не жорстко фіксований, то це дозволяє гнучко керувати електроспоживаннямвраховуючи погодинну зміну тарифів на електроенергію на протязі доби. Запропоновано евристичний підхід до«розумного» керування електроспоживанням на основі генетичного алгоритму, що є гарною альтернативою класичнимпідходам, як-то, наприклад, змішане цілочисельне лінійне програмування, яке обмежене до застосування в онлайн режимічерез свій офлайн характер та неможливість обробки складних обмежень,. Об’єктом дослідження є електроспоживанняелектроприймачів кількох блоків горизонту залізорудної шахти, що включають як постійно (вентиляція, водовідлив), так ізмінно (бурові верстати, лебідки) працюючі у часі навантаження. Цільова функція була сформульована таким чином, щобмінімізувати загальні витрати на електроенергію підземного залізорудного підприємства на протязі доби шляхомоптимізації розподілу часу підключення до електромережі кожного приймача. Під час дослідження були проаналізовані трипараметри налаштування генетичного алгоритму: обсяг популяції, вид функції схрещування та кількість елітних фенотипів.Найменші витрати на електроенергію (41454,99 грн) були досягнуті при розмірі популяції 100 фенотипів, 10 елітнихфенотипах в кожній популяції і функції схрещування Лапласа. Такі витрати були на 4,86% нижчими за найгірший результат(43470,55 грн), котрий мав місце при популяції 200 фенотипів, 0 елітних фенотипів і одноточковому виді схрещування.Виявилося, що число елітних фенотипів суттєво покращує якість роботи генетичного алгоритму та прискорює швидкістьоптимізації. Перехід від 0 до 20 елітних фенотипів скоротило кількість поколінь необхідних для мінімізації витрат наелектроенергію з 300 до 91 (на 69,7%). Також було встановлено, що мінімальні витрати на електроенергію підземногогірничорудного підприємства не завжди співпадають з найнижчими значеннями середньоквадратичної потужності, так яктут найважливішим є розподіл електроспоживання відносно часу коли діють пікові тарифи. Найбільш ефективніналаштування генетичного алгоритму забезпечили збалансованість споживання електроенергії на протязі доби, уникаючиспоживання у часові проміжки, коли тарифи максимальні. Результати дослідження підтвердили доцільність використаннягенетичного алгоритму під час керування споживанням електроенергії і та інтеграції подібних систем при впровадженніsmart grid-технологій у промислові енергосистеми.

  • Open Access

    The Multifactorial Approach to Power Quality Analysis in Underground Mining

    by Tetiana Beridze, Oleksii Mykhailenko, Ihor Sinchuk, Maryna Kotiakova, Mykhailo Rogoza, Maciej Jamiński

    This research presents the development of a multifactorial static multiplicative model for analysing power quality in underground mining power systems. The objective is to synthesize a generalized indicator of power quality by integrating key parameters such as voltage dips and sags, frequency deviations, harmonic distortion, and other critical indicators that influence the energy efficiency and reliability of the electrical network. The proposed model structure was developed using the synthesis method, with its parameters identified through a maladaptive approach based on the least squares method. To validate the model's accuracy, mathematical statistics techniques were employed. As a result, mathematical relationships were derived to evaluate a generalized power quality index using data on voltage drop, frequency deviation, and harmonic distortion. The model, characterized as static and multiplicative, requires full-spectrum quality data for parameter identification via a non-adaptive approach. Comparative accuracy analysis between a single-factor model and the proposed three-factor model revealed a correlation coefficient of 0.951 for the former and 0.923 for the latter. While the multifactor model demonstrates a 2.94% reduction in statistical accuracy, both models qualify as having "very high" reliability according to the Chaddock scale. This confirms the practical applicability of the multifactor approach in real-world mining energy systems. The scientific novelty lies in the improved multifactor model structure that synthesizes multiple quality indicators into a unified framework. Its practical value is evident in applications for managing power flow within industrial microgrids in underground mines, particularly those integrating local power generation sources.

  • Improving the efficiency of street lighting electrical systems

    by O. M Sinchuk, T. M Beridze, O. Yu Mykhailenko, V. V Horshkov, M. V Rogoza, R Strzelecki

    Purpose. To derive mathematical expressions that, using the available information, will allow forecasting the levels of electricity consumption by the city’s outdoor lighting network in the main possible scenarios for several years ahead, as well as when developing an energy-efficient smart control system for the electrotechnical complex of lighting complex. Methodology. Creating an effective intelligent outdoor lighting control system involves the use of the following methods. First, using the empirical measurement method, information on illumination, electricity consumption, car and pedestrian traffic is obtained. Statistical methods are used to identify patterns and relationships between the measured values, as well as to make subsequent forecasts. For intelligent control of outdoor lighting, a decision-making method based on fuzzy inference is used, which allows one, based on information about the operating conditions of the outdoor lighting network, to determine the recommended value of the current or value of lighting devices and the required power source. This approach will ensure maximum system efficiency. Findings. The obtained analytical dependencies for forecasting the electricity consumption, which are based on data from different time intervals, have determination coefficients of 66.8 and 88.1 %, respectively. The simulation of the operation of a fuzzy control system for the electricity consumption of outdoor lighting on the example of an operated part of the road operated and illuminated by ten 100 W LED lamps for summer and winter nights with different discrete control steps confirms the possibility of achieving the efficiency of outdoor lighting when using the proposed controllability option. The combined-powered control system is more efficient, reducing electricity consumption in summer and winter by more than 70 % compared to traditional control schemes. Originality. A fuzzy control system for the electrical complex of outdoor lighting in cities is improved, which takes into account the electricity tariff in addition to the level of illumination and the car or pedestrian traffic when generating the control action for the LED driver and determining the rational power source (grid or grid/battery) for lighting devices. Practical value. The architecture of the system for controlling electricity consumption by electrical receivers of lighting networks based on the fuzzy inference algorithm is developed, which is recommended for use to ensure an increase in the energy efficiency of this class of municipal consumers.

  • Fuzzy control system for the electrical complex of street lighting in settlements

    by Oleh Sinchuk, Oleksii Mykhailenko, Viktor Horshkov

    Oleh Sinchuk, Professor, Doctor in Technics (Doctor of Technic Sciences), Kryvyi Rih National University, Kryvyi Rih, Ukraine, e-mail: sinchuk@knu.edu.ua, ORCID ID: 0000-0002-7621-9979 Oleksii Mykhailenko, Associate Professor, PhD in Technics (Candidate of Technics Sciences), Kryvyi Rih National University, Kryvyi Rih, Ukraine, e-mail: mykhailenko@knu.edu.ua , ORCID ID: 0000-0003-2898-6652 Viktor Horshkov, Mining and Electromechanical College of Kryvyi Rih National University, Kryvyi Rih, Ukraine, e-mail: horshkov@knu.edu.ua The article deals with the issue of improving the energy efficiency of electrical systems that provide comfortable living conditions for the population of cities and towns, namely street lighting. A fuzzy control system for a group of LED luminaires of a road section is created that regulates the power of the lighting devices and, accordingly, their brightness and controls the connection to a power source (either to the grid or to a battery) depending on the level of illumination, traffic intensity and electricity tariff. It was found that a controlled system with combined power supply is more efficient. It reduces electricity consumption on a typical summer night by 75.31% and 74.93%, and on a winter night by 80.4% and 77.68% compared to the traditional street lighting option, when the lighting network is either completely shut down at night or operates at only 50% of capacity, respectively. It can be stated that the fuzzy control system for the electrical complex of street lighting is energy efficient. It is also recommended that specialized enterprises in settlements responsible for the lighting network pay more attention not only to replacing light sources with new, more energy-efficient ones, but also to introducing alternative power sources for lighting installations that allow charging batteries during daylight hours, such as solar panels. This, along with the use of the fuzzy control system under consideration, will make it possible to save even more on electricity costs, which is very important in today's environment.

  • Heuristic control of power consumption by up to 1000 V electrical loads at mining enterprises

    by O. M Sinchuk, M. V Rogoza, O. Yu Mykhailenko, D. V Kobeliatskyi, V. O Fedotov

    Purpose. To develop a method for synthesizing the structure and algorithm of the system for automated control of power consumption by up to 1000 V electrical receivers at mining enterprises with iron ore underground mining methods. This enables direct control of the load connection to the industrial power grid to ensure minimum power costs depending on its cost per day ahead. Methodology. The problem of controlling power consumption of electrical receivers at iron ore underground mines is formalized as a binary form of mixed integer programming. To solve it, a binary implementation of the heuristic genetic algorithm is used. The mathematical modeling method analyzes the impact of genetic algorithm settings, such as the number of phenotypes in the population, the number of elite phenotypes that pass unchanged to the next generation, and the method of phenotype crossover on its quality. Findings. As a result of the research, it is found that the most effective way to control the process of power consumption based on an evolutionary genetic algorithm is to use the Laplace crossover function and keep the percentage of elite phenotypes in the population at 10 %. Moreover, at the smallest population size, the best accuracy is observed when using the Laplace function, while at one- and two-point crossover functions, it worsens, but not significantly (no more than 0.2 %). However, as the number of elite phenotypes increases, the duration of the evolutionary search in the control process is reduced by almost a factor of two in the case of one- and two-point crossovers. Originality. For the first time, the structure of a heuristic system for automated control of power consumption by underground electrical receivers with a supply voltage of up to 1000 V at iron ore underground mines has been developed on the basis of an evolutionary genetic algorithm. Depending on the designed volumes of ore production and the daily power cost per day, this allows determining the optimal power load schedule of underground distribution substations in advance, which, subject to the accepted limits on hourly and daily power, minimizes the cost of purchasing power, and thus reduces the cost of the final product. Practical value. The architecture of a heuristic system for controlling power consumption by electrical receivers with a voltage of up to 1000 V based on an evolutionary genetic algorithm is developed and recommended when optimizing the power load schedule of transformer substations of mining and metallurgical enterprises, in particular, of iron ore underground mines operating in this voltage class.


  • Open Access

    PUMPED-STORAGE HYDROELECTIC POWER PLANTS AS SOURCES OF DISTRIBUTED POWER GENERATION AS PART OF INDUSTRIAL POWER SYSTEMS

    by O. Mykhailenko, I. Sinchuk, K. Budnikov

    The article examines the economic aspects of the efficiency of power systems for mine loads, which include peak pumped-storage hydroelectric power plants that use reservoirs of the mine underground water drainage. The compari-son of power supply options was carried out according to the net present value (NPV) criterion, which was determined by changing the water inflow through the hydro turbine and power consumption. As a result of numerical experiments, it has been established that the greatest economic effect can be achieved by implementing a pumped-storage hydroelec-tric power plant consisting of four hydroturbines, two of which will be used during the half-peak price hours, and at other times, when the peak price is used, all facilities will be used to. Ref. 10, fig. 3, table. Key words: pumped-storage hydroelectric power plant, distributed power generation, mine drainage, net present value, efficiency.

  • Open Access

    Modeling and simulating dynamics of lithium-ion batteries using block-oriented models with piecewise linear static nonlinearity

    by Oleksii Mykhailenko

    The article deals with the research of the efficiency of modelling the dynamics of voltage change in lithium-ion rechargeable batteries in charging/discharging modes using nonlinear block-oriented systems. Drawing on experimental data, a structural and parametric identification of the Hammerstein, Wiener and Hammerstein-Wiener models with a polynomial structure of the linear dynamic block and piecewise linear static nonlinearities was performed. It has been established that the best modelling accuracy was ensured by using the Hammerstein-Wiener system with a linear model having the 6th order of the numerator and denominator polynomials and an input delay of 3 samples. It showed 15.67% and 6.2% higher accuracy compared to the Wiener and Hammerstein systems, respectively. The application of those models in battery management systems will make it possible to improve the control quality for battery assemblies of solar and wind power plants in the context of the variable nature of the charging/discharging processes due to the variability of weather conditions and fluctuations in power consumption during a 24-hour period. This will ensure a wider introduction of renewable power generation into existing power systems, which is currently the leading way to ensure sustainable development of the energy sector.