Mykhailo Rogoza
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mykhailo Rogoza has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Oleg Sinchuk
Kryvyi Rih National University,Department of automated electromechanical systems in the industry and vehiclesKryvyi RihUkraine
2 shared publications - Oleksii Mykhailenko
Kryvyi Rih National University, Department of Power Systems and Energy Management, 11 Vitalii Matusevysch Str., Kryvyi Rih, 50027, Ukraine
2 shared publications - Vadym Reva
Державне Підприємство Конструкторське Бюро «Південне» ім М.К. Янгеля
2 shared publications - Yurii Papaika
Dnipro University of Technology, Dmytra Yavornytskoho Ave 19, Dnipro, Ukraine; Dnipropetrovsk Research Institute of Judicial Examination, Sicheslavska Naberezhna St, 17, Of. 801, Dnipro, Ukraine
2 shared publications - Andrey Kupin
Kryvyi Rih National University,Kryvyi Rih,Ukraine
1 shared publication - Danyil Kobeliatskyi1 shared publication
Latest Publications
- 30 December 2024
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 6,p. 66-72
Improving the efficiency of street lighting electrical systems
Purpose. To derive mathematical expressions that, using the available information, will allow forecasting the levels of electricity consumption by the city’s outdoor lighting network in the main possible scenarios for several years ahead, as well as when developing an energy-efficient smart control system for the electrotechnical complex of lighting complex. Methodology. Creating an effective intelligent outdoor lighting control system involves the use of the following methods. First, using the empirical measurement method, information on illumination, electricity consumption, car and pedestrian traffic is obtained. Statistical methods are used to identify patterns and relationships between the measured values, as well as to make subsequent forecasts. For intelligent control of outdoor lighting, a decision-making method based on fuzzy inference is used, which allows one, based on information about the operating conditions of the outdoor lighting network, to determine the recommended value of the current or value of lighting devices and the required power source. This approach will ensure maximum system efficiency. Findings. The obtained analytical dependencies for forecasting the electricity consumption, which are based on data from different time intervals, have determination coefficients of 66.8 and 88.1 %, respectively. The simulation of the operation of a fuzzy control system for the electricity consumption of outdoor lighting on the example of an operated part of the road operated and illuminated by ten 100 W LED lamps for summer and winter nights with different discrete control steps confirms the possibility of achieving the efficiency of outdoor lighting when using the proposed controllability option. The combined-powered control system is more efficient, reducing electricity consumption in summer and winter by more than 70 % compared to traditional control schemes. Originality. A fuzzy control system for the electrical complex of outdoor lighting in cities is improved, which takes into account the electricity tariff in addition to the level of illumination and the car or pedestrian traffic when generating the control action for the LED driver and determining the rational power source (grid or grid/battery) for lighting devices. Practical value. The architecture of the system for controlling electricity consumption by electrical receivers of lighting networks based on the fuzzy inference algorithm is developed, which is recommended for use to ensure an increase in the energy efficiency of this class of municipal consumers.
- 30 December 2024
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 6,p. 66-72
Improving the efficiency of street lighting electrical systems
Purpose. To derive mathematical expressions that, using the available information, will allow forecasting the levels of electricity consumption by the city’s outdoor lighting network in the main possible scenarios for several years ahead, as well as when developing an energy-efficient smart control system for the electrotechnical complex of lighting complex. Methodology. Creating an effective intelligent outdoor lighting control system involves the use of the following methods. First, using the empirical measurement method, information on illumination, electricity consumption, car and pedestrian traffic is obtained. Statistical methods are used to identify patterns and relationships between the measured values, as well as to make subsequent forecasts. For intelligent control of outdoor lighting, a decision-making method based on fuzzy inference is used, which allows one, based on information about the operating conditions of the outdoor lighting network, to determine the recommended value of the current or value of lighting devices and the required power source. This approach will ensure maximum system efficiency. Findings. The obtained analytical dependencies for forecasting the electricity consumption, which are based on data from different time intervals, have determination coefficients of 66.8 and 88.1 %, respectively. The simulation of the operation of a fuzzy control system for the electricity consumption of outdoor lighting on the example of an operated part of the road operated and illuminated by ten 100 W LED lamps for summer and winter nights with different discrete control steps confirms the possibility of achieving the efficiency of outdoor lighting when using the proposed controllability option. The combined-powered control system is more efficient, reducing electricity consumption in summer and winter by more than 70 % compared to traditional control schemes. Originality. A fuzzy control system for the electrical complex of outdoor lighting in cities is improved, which takes into account the electricity tariff in addition to the level of illumination and the car or pedestrian traffic when generating the control action for the LED driver and determining the rational power source (grid or grid/battery) for lighting devices. Practical value. The architecture of the system for controlling electricity consumption by electrical receivers of lighting networks based on the fuzzy inference algorithm is developed, which is recommended for use to ensure an increase in the energy efficiency of this class of municipal consumers.
- 29 February 2024
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 1,p. 84-91
Heuristic control of power consumption by up to 1000 V electrical loads at mining enterprises
Purpose. To develop a method for synthesizing the structure and algorithm of the system for automated control of power consumption by up to 1000 V electrical receivers at mining enterprises with iron ore underground mining methods. This enables direct control of the load connection to the industrial power grid to ensure minimum power costs depending on its cost per day ahead. Methodology. The problem of controlling power consumption of electrical receivers at iron ore underground mines is formalized as a binary form of mixed integer programming. To solve it, a binary implementation of the heuristic genetic algorithm is used. The mathematical modeling method analyzes the impact of genetic algorithm settings, such as the number of phenotypes in the population, the number of elite phenotypes that pass unchanged to the next generation, and the method of phenotype crossover on its quality. Findings. As a result of the research, it is found that the most effective way to control the process of power consumption based on an evolutionary genetic algorithm is to use the Laplace crossover function and keep the percentage of elite phenotypes in the population at 10 %. Moreover, at the smallest population size, the best accuracy is observed when using the Laplace function, while at one- and two-point crossover functions, it worsens, but not significantly (no more than 0.2 %). However, as the number of elite phenotypes increases, the duration of the evolutionary search in the control process is reduced by almost a factor of two in the case of one- and two-point crossovers. Originality. For the first time, the structure of a heuristic system for automated control of power consumption by underground electrical receivers with a supply voltage of up to 1000 V at iron ore underground mines has been developed on the basis of an evolutionary genetic algorithm. Depending on the designed volumes of ore production and the daily power cost per day, this allows determining the optimal power load schedule of underground distribution substations in advance, which, subject to the accepted limits on hourly and daily power, minimizes the cost of purchasing power, and thus reduces the cost of the final product. Practical value. The architecture of a heuristic system for controlling power consumption by electrical receivers with a voltage of up to 1000 V based on an evolutionary genetic algorithm is developed and recommended when optimizing the power load schedule of transformer substations of mining and metallurgical enterprises, in particular, of iron ore underground mines operating in this voltage class.
- 29 February 2024
- Published by Dnipro University of Technology in Naukovyi Visnyk Natsionalnoho Hirnychoho Universytetu
- No. 1,p. 84-91
Heuristic control of power consumption by up to 1000 V electrical loads at mining enterprises
Purpose. To develop a method for synthesizing the structure and algorithm of the system for automated control of power consumption by up to 1000 V electrical receivers at mining enterprises with iron ore underground mining methods. This enables direct control of the load connection to the industrial power grid to ensure minimum power costs depending on its cost per day ahead. Methodology. The problem of controlling power consumption of electrical receivers at iron ore underground mines is formalized as a binary form of mixed integer programming. To solve it, a binary implementation of the heuristic genetic algorithm is used. The mathematical modeling method analyzes the impact of genetic algorithm settings, such as the number of phenotypes in the population, the number of elite phenotypes that pass unchanged to the next generation, and the method of phenotype crossover on its quality. Findings. As a result of the research, it is found that the most effective way to control the process of power consumption based on an evolutionary genetic algorithm is to use the Laplace crossover function and keep the percentage of elite phenotypes in the population at 10 %. Moreover, at the smallest population size, the best accuracy is observed when using the Laplace function, while at one- and two-point crossover functions, it worsens, but not significantly (no more than 0.2 %). However, as the number of elite phenotypes increases, the duration of the evolutionary search in the control process is reduced by almost a factor of two in the case of one- and two-point crossovers. Originality. For the first time, the structure of a heuristic system for automated control of power consumption by underground electrical receivers with a supply voltage of up to 1000 V at iron ore underground mines has been developed on the basis of an evolutionary genetic algorithm. Depending on the designed volumes of ore production and the daily power cost per day, this allows determining the optimal power load schedule of underground distribution substations in advance, which, subject to the accepted limits on hourly and daily power, minimizes the cost of purchasing power, and thus reduces the cost of the final product. Practical value. The architecture of a heuristic system for controlling power consumption by electrical receivers with a voltage of up to 1000 V based on an evolutionary genetic algorithm is developed and recommended when optimizing the power load schedule of transformer substations of mining and metallurgical enterprises, in particular, of iron ore underground mines operating in this voltage class.
- 1 January 2024
- Published by Publishing House Helvetica (Publications) in Transactions of Kremenchuk Mykhailo Ostrohradskyi National University
- No. 6 (149),p. 201-210
ANALYSIS OF POSSIBLE THE OFF-NOMINAL SITUATIONS AND METHODS OF THEIR MANAGEMENT DURING THE OPERATION OF POWER SUPPLY SYSTEMS OF SPACE ROCKET COMPLEXES
- 1 January 2024
- Published by Publishing House Helvetica (Publications) in Transactions of Kremenchuk Mykhailo Ostrohradskyi National University
- No. 6 (149),p. 201-210
ANALYSIS OF POSSIBLE THE OFF-NOMINAL SITUATIONS AND METHODS OF THEIR MANAGEMENT DURING THE OPERATION OF POWER SUPPLY SYSTEMS OF SPACE ROCKET COMPLEXES
- 1 January 2020
- Published by Dnipro University of Technology in Mining of Mineral Deposits
- Vol. 14 (3) , 101-111
Certain aspects concerning the development of a functioning scheme of the auto-mated system to control energy flows of underground iron-ore enterprises
- 1 January 2020
- Published by Dnipro University of Technology in Mining of Mineral Deposits
- Vol. 14 (3) , 101-111
Certain aspects concerning the development of a functioning scheme of the auto-mated system to control energy flows of underground iron-ore enterprises