    Realization of long axial field-of-view PET technology in the clinic and research environment

    by Florence M Muller, Margaret E Daube-Witherspoon, Elizabeth J Li, Austin R Pantel, Joel S Karp

    Long axial field-of-view (AFOV) PET-CT instruments have significantly higher sensitivity than conventional PET scanners, allowing for reduced scan time and/or reduced radiotracer dose. The long axial coverage also permits multiorgan dynamic imaging with fine temporal sampling. In this article, we discuss how the technical advantages of long AFOV PET instruments are being realized in the clinic and exploited in research studies. We describe some practical considerations for these systems in the clinic, as well as their benefits beyond the clinic. We consider alternate scanner designs to mitigate the high cost of long AFOV systems currently in use and describe how deep learning is being applied to long AFOV PET studies to reduce image noise, allowing for even shorter scans to minimize motion, aid in dynamic imaging applications, and image generation. We conclude with some ideas on what future developments may be on the horizon for long AFOV PET.


  • Randoms Estimation for Long Axial Field-of-View PET

    by Margaret E. Daube-Witherspoon, Stephen C. Moore, Joel S. Karp

    The high sensitivity of long axial field-of-view (AFOV) PET scanners has enabled studies over a wide range of count rates and count densities. However, these systems have a large axial acceptance angle that necessitates a wide coincidence window to capture the oblique true coincidences. In addition, the measured delays sinogram is sparse and noisy. We studied four methods of randoms estimation on a long AFOV system to assess their impact on accuracy and image noise: measured delays using a delayed coincidence window (RD), 2D Casey averaging of measured delays (RD-smooth), 2D average of measured delays (RD-ave – the current default method on the PennPET Explorer), and estimation of randoms from singles (RS). We looked at cases with varying count densities, randoms fractions, and non-pure positron emitters. A positive bias observed at low randoms counts for the RD and RD-smooth methods was not seen with the RD-ave or RS methods. For all cases, quantitative results with RS agreed to within 2.5% of the RD-ave method, while RD and RD-smooth estimates showed differences of 5-49%, with larger differences in areas of low uptake. The RS method is a practical technique for list-mode data and list-mode reconstruction by reducing the size of stored list events. It also avoids small approximations in the RDave method. For long AFOV systems, estimating randoms from singles is a practical and accurate method.

  • Open Access

    Impact of deep learning denoising on kinetic modelling for low-dose dynamic PET: application to single- and dual-tracer imaging protocols

    by Florence M. Muller, Elizabeth J. Li, Margaret E. Daube-Witherspoon, Austin R. Pantel, Corinde E. Wiers, Jacob G. Dubroff, Christian Vanhove, Stefaan Vandenberghe, Joel S. Karp

    Purpose: Long-axial field-of-view PET scanners capture multi-organ tracer distribution with high sensitivity, enabling lower dose dynamic protocols and dual-tracer imaging for comprehensive disease characterization. However, reducing dose may compromise data quality and time-activity curve (TAC) fitting, leading to higher bias in kinetic parameters. Parametric imaging poses further challenges due to noise amplification in voxel-based modelling. We explore the potential of deep learning denoising (DL-DN) to improve quantification for low-dose dynamic PET. Methods: Using 16 [18F]FDG PET studies from the PennPET Explorer, we trained a DL framework on 10-min images from late-phase uptake (static data) that were sub-sampled from 1/2 to 1/300 of the counts. This model was used to denoise early-to-late dynamic frame images. Its impact on quantification was evaluated using compartmental modelling and voxel-based graphical analysis for parametric imaging for single- and dual-tracer dynamic studies with [18F]FDG and [18F]FGln at original (injected) and reduced (sub-sampled) doses. Quantification differences were evaluated for the area under the curve of TACs, Ki for [18F]FDG and VT for [18F]FGln, and parametric images. Results: DL-DN consistently improved image quality across all dynamic frames, systematically enhancing TAC consistency and reducing tissue-dependent bias and variability in Ki and VT down to 40 MBq doses. DL-DN preserved tumor heterogeneity in Logan VT images and delineation of high-flux regions in Patlak Ki maps. In a /[18F]FDG dual-tracer study, bias trends aligned with single-tracer results but showed reduced accuracy for [¹⁸F]FGln in breast lesions at very low doses (4 MBq). Conclusion: This study demonstrates that applying DL-DN trained on static [18F]FDG PET images to dynamic [18F]FDG and [18F]FGln PET can permit significantly reduced doses, preserving accurate FDG Ki and FGln VT measurements, and enhancing parametric image quality. DL-DN shows promise for improving dynamic PET quantification at reduced doses, including novel dual-tracer studies.


  • Total-body PET: a new paradigm for molecular imaging

    by Margaret E Daube-Witherspoon, Austin R Pantel, Daniel A Pryma, Joel S Karp

    Total body (TB) positron emission tomography (PET) instruments have dramatically changed the paradigm of PET clinical and research studies due to their very high sensitivity and capability to image dynamic radiopharmaceutical distributions in the major organs of the body simultaneously. In this manuscript, we review the design of these systems and discuss general challenges and trade-offs to maximize the performance gains of current TB-PET systems. We then describe new concepts and technology that may impact future TB-PET systems. The manuscript summarizes what has been learned from the initial sites with TB-PET and explores potential research and clinical applications of TB-PET. The current generation of TB-PET systems range in axial field-of-view (AFOV) from 1 to 2 m and serve to illustrate the benefits and opportunities of a longer AFOV for various applications in PET. In only a few years of use these new TB-PET systems have shown that they will play an important role in expanding the field of molecular imaging and benefiting clinical practice.


  • Abbreviated scan protocols to capture 18F-FDG kinetics for long axial FOV PET scanners

    by Varsha Viswanath, Hasan Sari, Austin R. Pantel, Maurizio Conti, Margaret E. Daube-Witherspoon, Clemens Mingels, Ian Alberts, Lars Eriksson, Kuangyu Shi, Axel Rominger, et al.

    Purpose Kinetic parameters from dynamic 18F-fluorodeoxyglucose (FDG) imaging offer complementary insights to the study of disease compared to static clinical imaging. However, dynamic imaging protocols are cumbersome due to the long acquisition time. Long axial field-of-view (LAFOV) PET scanners (> 70 cm) have two advantages for dynamic imaging over clinical PET scanners with a standard axial field-of-view (SAFOV; 16–30 cm). The large axial coverage enables multi-organ dynamic imaging in a single bed position, and the high sensitivity may enable clinically routine abbreviated dynamic imaging protocols. Methods In this work, we studied two abbreviated protocols using data from a 65-min dynamic 18F-FDG scan: (A) dynamic imaging immediately post-injection (p.i.) for variable durations, and (B) dynamic imaging immediately p.i. for variable durations plus a 1-h p.i. (5-min-long) datapoint. Nine cancer patients were imaged on the Biograph Vision Quadra (Siemens Healthineers). Time-activity curves over the lesions (N = 39) were fitted using the Patlak graphical analysis and a 2-tissue-compartment (2C, k4 = 0) model for variable scan durations (5–60 min). Kinetic parameters from the complete dataset served as the reference. Lesions from all cancers were grouped into low, medium, and high flux groups, and bias and precision of Ki (Patlak) and Ki, K1, k2, and k3 (2C) were calculated for each group. Results Using only early dynamic data with the 2C (or Patlak) model, accurate quantification of Ki required at least 50 (or 55) min of dynamic data for low flux lesions, at least 30 (or 40) min for medium flux lesions, and at least 15 (or 20) min for high flux lesions to achieve both 10% bias and precision. The addition of the final (5-min) datapoint allowed for accurate quantification of Ki with a bias and precision of 10% using only 10–15 min of early dynamic data for either model. Conclusion Dynamic imaging for 10–15 min immediately p.i. followed by a 5-min scan at 1-h p.i can accurately and precisely quantify 18F-FDG on a long axial FOV scanner, potentially allowing for more widespread use of dynamic 18F-FDG imaging.


  • Scanner Design Considerations for Long Axial Field-of-View PET Systems

    by Margaret E. Daube-Witherspoon, Simon R. Cherry


  • Performance Characteristics of Long Axial Field-of-View PET Scanners With Axial Gaps

    by Margaret E. Daube-Witherspoon, Varsha Viswanath, Matthew E. Werner, Joel S. Karp

    The introduction of long (>60 cm) axial field-of-view (LAFOV) PET systems has shown their potential for clinical and research applications. LAFOV scanners are expensive, so there is interest in designing systems with longer axial coverage while mitigating cost by introducing detector gaps. We used measurements on the PennPET Explorer (64-cm axial field-of-view (AFOV) prototype) and simulations of scanners up to 143-cm long to assess scanner performance with axial gaps introduced by varying the number of detector rows in each ring. Removing detectors reduces the total sensitivity and results in a nonuniform axial noise profile. Axial resolution shows small (<; 0.5 mm) loss from the edge of the AFOV to the center, even for a 143-cm AFOV scanner with an unrestricted acceptance angle. The presence of large axial gaps increases the variability in axial resolution and contrast recovery across the AFOV compared to a system without gaps. More modest axial gaps show less variable behavior. The results suggest that designs where the gap is no larger than one-half of the width of a detector ring may be preferred, although the optimal choice of scanner design with the tradeoffs of performance and AFOV will depend on its intended usage.


  • Quantifying Bias and Precision of Kinetic Parameter Estimation on the PennPET Explorer, a Long Axial Field-of-View Scanner

    by Varsha Viswanath, Austin R. Pantel, Margaret E. Daube-Witherspoon, Robert Doot, Mark Muzi, David A. Mankoff, Joel S. Karp

    Long axial field-of-view (AFOV) PET scanners allow for full-body dynamic imaging in a single bed-position at very high sensitivity. However, the benefits for kinetic parameter estimation have yet to be studied. This work uses 1) a dynamic Geant4 Application for Tomographic Emission (GATE) simulation of [ 18 F]-fluorothymidine (FLT) in a modified NEMA IQ phantom and 2) a lesion embedding study of spheres in a dynamic [18F]-fluorodeoxyglucose (FDG) human subject imaged on the PennPET Explorer. Both studies were designed using published kinetic data of lung and liver cancers and modeled using two tissue compartments. Data were reconstructed at various emulated doses. Sphere time-activity curves (TACs) were measured on resulting dynamic images, and TACs were fit using a two-tissue-compartment model (k 4 ≠ 0) for the FLT study and both a two-tissue-compartment model (k 4 = 0) and Patlak graphical analysis for the FDG study to estimate flux (Ki) and delivery (K 1 ) parameters. Quantification of flux and K 1 shows lower bias and better precision for both radiotracers on the long AFOV scanner, especially at low doses. Dynamic imaging on a long AFOV system can be achieved for a greater range of injected doses, as low as 0.5-2 mCi depending on the sphere size and flux, compared to a standard AFOV scanner, while maintaining good kinetic parameter estimation.