    A systematic characterization of plastic scintillation dosimeters response in magnetic fields: I. Experimental measurements

    by Yunuen Cervantes, Simon Lambert-Girard, Ilias Billas, François Therriault-Proulx, Hugo Bouchard, Louis Archambault, Luc Beaulieu

    Objective. This study aims to evaluate the performance of five distinct plastic scintillation dosimeters (PSDs) in magnetic fields, as well as to validate the accuracy of the hyperspectral approach for stem-effect correction. The effect of the magnetic field on different base core materials and components within the PSDs was also investigated, as well as the effect of field size and orientation. Approach. Each PSD was placed at 5 cm depth in a water tank inside an electromagnet gap. Magnetic fields, between 0 and 1.5 T, were set to be perpendicular to the 6 MeV photon beam and to the PSD axis. The detector axis was either parallel or perpendicular to the photon beam. Different field sizes were used. The hyperspectral technique was validated and used to determine the scintillation, fluorescence and Cherenkov components at different magnetic fields. Main results. The hyperspectral method accurately removes stem effects in magnetic fields, even when calibration is performed at 0 T. The stem light yield shows good agreement with clear fiber measurements, with relative differences within 2.0%. In the parallel orientation, the corrected PSD response is highly symmetric relative to magnetic field polarity, with a maximum variation of only 0.2% from unity. Scintillation light yield increases with magnetic field by 3.6%–6.25% depending on PSD properties. Cherenkov light yield varies up to 230% and down to 0.30% of the 0 T value, depending on magnetic field polarity. The impact of magnetic fields depends primarily on the properties of the scintillator itself, with polyvinyltoluene-based probes showing greater sensitivity than polystyrene-based probes. The inclusion of a wavelength shifter has minimal on the magnetic field’s effect on scintillation light yield. Normalized scintillation light yield decreases with smaller field sizes. Significance. PSDs are well-suited for accurate dosimetry in magnetic fields, provided that accurate stem-effect correction techniques are applied. The scintillator properties play a significant role in determining the PSD’s sensitivity to magnetic fields. The hyperspectral method is a robust approach for accurate stem-effect removal in such conditions.


  • Open Access

    A systematic characterization of plastic scintillation dosimeters response in magnetic fields: II. Monte Carlo simulations

    by Yunuen Cervantes, Simon Lambert-Girard, Ilias Billas, François Therriault-Proulx, Hugo Bouchard, Louis Archambault, Luc Beaulieu

    Purpose. This study aims to investigate and validate the response of plastic scintillation dosimeters (PSDs) in the presence of magnetic fields using Monte Carlo simulations, focusing on the accuracy of electron fluence, dose calculations, and the optical processes of scintillation and Cherenkov radiation. Methods. Monte Carlo simulations, using EGSnrc and TOPAS, of the PSD response under magnetic fields were performed. First, electron fluence simulations were conducted with three different physics lists g4em-penelope, g4em-standard_opt3 and g4em-standard_opt4, with the goal of benchmarking their performance in magnetic fields. Secondly, a Fano test for dose calculations was performed using only the g4em-penelope physics list. Thirdly, the Cherenkov process under magnetic fields was validated against theoretical predictions. Finally, a PSD probe was modeled and simulated, with results compared against measurements. Results. The g4em-penelope physics list demonstrated a most balanced performance, showing the closest agreement with EGSnrc simulations and lower variability in magnetic fields than g4em-standard_opt4. Fano test results showed an accuracy of at least 0.36% for dose calculations. Simulations of Cherenkov radiation in ideal conditions were in agreement with theoretical predictions at both 0 T and 1.5 T. Monte Carlo simulations successfully reproduced experimental trends for Cherenkov radiation under magnetic fields. However, discrepancies were found, with deviations of up to 7.7% when electrons were deflected towards the tip and up to 21.0% in the opposite direction, likely due to modeling limitations. A key result is that Monte Carlo simulations of the scintillation process in magnetic fields failed to reproduce experimental observations. While experimental results showed a significant effect of magnetic fields on scintillation yield, the simulations did not reflect this behavior. Conclusion. This study establishes that TOPAS, specifically using the g4em-penelope physics list, is a reliable tool for simulating dose, electron fluence, and Cherenkov radiation in the presence of magnetic fields. However, significant discrepancies were observed in the scintillation processes, where Monte Carlo simulations failed to reproduce the effect of magnetic fields seen in experimental measurements. These findings point out the need for further refinement of simulation models, particularly in accurately representing scintillation under magnetic fields.


  • Open Access

    Monte Carlo investigation of electron fluence perturbation in MRI-guided radiotherapy beams using six commercial radiation detectors

    by Yunuen Cervantes, Simon Duane, Hugo Bouchard

    With the integration of treatments with MRI-linacs to the clinical workflow, the understanding and characterization of detector response in reference dosimetry in magnetic fields are required. The external magnetic field perturbs the electron fluence. The degree of perturbation depends on the irradiation conditions and on the detector type. The purpose of this study is to evaluate the magnetic field impact on the electron fluence spectra in several detectors to provide a deeper understanding of detector response in these conditions. Monte Carlo calculations of the electron fluence are performed in six detectors (solid-state: PTW60012 and PTW60019, ionization chambers: PTW30013, PTW31010, PTW31021, and PTW31022) in water and irradiated by a 7 MV FFF photon beam with a small and a reference field, at 0 and 1.5 T. Three chamber axis orientations are investigated: parallel or perpendicular (either the Lorentz force pointing towards the stem or the tip) to the magnetic field and always perpendicular to the photon beam. One orientation for the solid-state detector is studied: parallel to the photon beam and perpendicular to the magnetic field. Additionally, electron fluence spectra are calculated in modified detector geometries to identify the underlying physical mechanisms behind the fluence perturbations. The total electron fluence in the Farmer chamber varies up to 1.24% and 5.12% at 1.5 T, in the parallel and perpendicular orientation, respectively. The interplay between the gyration radius and the Farmer chamber cavity length significantly affects the electron fluence in the perpendicular orientation. For the small-cavity chambers, the maximal variation in total electron fluence is 0.19% in the parallel orientation for the reference field. Significant small-field effects occur in these chambers; the magnetic field reduces the total electron fluence (with respect to the no field case) between 9.86% and 14.50%, depending on the orientation. The magnetic field strongly impacted the solid-state detectors in both field sizes, probably due to the high-Z components and cavity density. The maximal reductions of total electron fluence are 15.06 ± 0.09% (silicon) and 16.00 ± 0.07% (microDiamond). This work provides insights into detector response in magnetic fields by illustrating the interplay between several factors causing dosimetric perturbation effects: (1) chamber and magnetic field orientation, (2) cavity size and shape, (3) extracameral components, (4) air gaps and their asymmetry, (5) electron energy. Low-energy electron trajectories are more susceptible to change in magnetic fields, and are associated with detector response perturbation. Detectors with higher density and high-Z extracameral components exhibit more significant perturbations in the presence of a magnetic field, regardless of field size.


  • Open Access

    Monte Carlo calculation of detector perturbation and quality correction factors in a 1.5 T magnetic resonance guided radiation therapy small photon beams

    by Yunuen Cervantes, Jasmine Duchaine, Ilias Billas, Simon Duane, Hugo Bouchard

    Objective. With future advances in magnetic resonance imaging-guided radiation therapy, small photon beams are expected to be included regularly in clinical treatments. This study provides physical insights on detector dose-response to multiple megavoltage photon beam sizes coupled to magnetic fields and determines optimal orientations for measurements. Approach. Monte Carlo simulations determine small-cavity detector (solid-state: PTW60012 and PTW60019, ionization chambers: PTW31010, PTW31021, and PTW31022) dose-responses in water to an Elekta Unity 7 MV FFF photon beam. Investigations are performed for field widths between 0.25 and 10 cm in four detector axis orientations with respect to the 1.5 T magnetic field and the photon beam. The magnetic field effect on the overall perturbation factor (P MC) accounting for the extracameral components, atomic composition, and density is quantified in each orientation. The density (P ρ ) and volume averaging (P vol) perturbation factors and quality correction factors ( k Q B , Q f B , f ) accounting for the magnetic field are also calculated in each orientation. Main results. Results show that P vol remains the most significant perturbation both with and without magnetic fields. In most cases, the magnetic field effect on P vol is 1% or less. The magnetic field effect on P ρ is more significant on ionization chambers than on solid-state detectors. This effect increases up to 1.564 ± 0.001 with decreasing field size for chambers. On the contrary, the magnetic field effect on the extracameral perturbation factor is higher on solid-state detectors than on ionization chambers. For chambers, the magnetic field effect on P MC is only significant for field widths Significance. Solid-state detectors’ dose-response is strongly affected by the magnetic field in all orientations. The magnetic field impact on ionization chamber response increases with decreasing field size. In general, ionization chambers yield k Q B , Q f B , f closer to unity, especially in orientations where the chamber axis is parallel to the magnetic field.


  • Small-cavity chamber dose response in megavoltage photon beams coupled to magnetic fields

    by Yunuen Cervantes, Ilias Billas, David R Shipley, Simon Duane, Hugo Bouchard

    In MRgRT, dosimetry measurements are performed in the presence of magnetic fields. For high-resolution measurements, small-cavity ionization chambers are required. While Monte Carlo simulations are essential to determine dosimetry correction factors, models of small-chambers require careful validation with experimental measurements. The aim of this study is to characterize small-cavity chamber response coupled to magnetic fields. Small-cavity chambers (PTW31010, PTW31016, PTW31021 and PTW3022) are irradiated by a 6 MV photon beam for 9 magnetic field strengths between -1.5 T and +1.5 T. The chamber axis is orientated either parallel or perpendicular to the irradiation beam, with the magnetic field always perpendicular to the beam. MC simulations are performed in EGSnrc. The sensitive volume of the chambers is reduced to account for the inefficiency adjacent to the guard electrode (dead volume) based on COMSOL calculations of electric potentials. The magnetic field affects the chamber response by up to 4.1% and 4.5% in the parallel and perpendicular orientations, respectively, compared to no magnetic field. The maximal difference in dose response between experiments and simulations is up to 6.1% and 4.5% for parallel and perpendicular orientation, respectively. When the dead volume is removed, which accounts for the 15%-23% of the nominal volume, the difference, in most cases, is within the stated uncertainties. Nevertheless, for a particular chamber, the reduced nominal volume barely improved the agreement between the experimental and calculated relative response (4.53% to 4.13%). This disagreement may be due to the imperfect chamber geometry model, as was found from microCT images. A detailed uncertainty analysis is presented. The characterization of small-cavity ion chamber response coupled to magnetic fields is complex. Small differences between real and model chamber geometry that normally would be insignificant become an issue in the presence of magnetic fields. Accurate characterization of the nominal volume is essential for small-cavity ion chamber modelling.