  • Degradation, Lifetime, and Failure Modes of Metal Oxide Varistors in Low-Voltage DC Circuit Breaker Applications

    by Yang Liu, Kayla Chuong, Yichuan Liu, Zhi Jin Zhang, Lauren M. Garten, Lukas Graber

    The metal oxide varistor (MOV) has been a critical enabling component for emerging applications in low-voltage dc circuit breakers (LVDCCBs). Although its properties align well with this application, its long-term performance, including degradation, failure modes, and service lifetime, remains poorly understood. Based on an accelerated degradation test (ADT) platform, this work collects extensive data to track degradation patterns and identify failure modes using statistical methods. A power-function-based model is proposed to identify the driving forces behind degradation, and a complete lifetime map of LVDCCB MOVs is achieved. The model predicts the lifetime of LVDCCB MOVs with a confidence level of 79.18%. The model and statistical analysis indicate that charge is the driving force for the defined failure mode, which needs to be addressed in the LVDCCB design while energy drives the catastrophic failure mode, which needs to be avoided in the LVDCCB design.

  • A Dual-Loop Frequency-Feedforward PLL for Three-Phase VSC Transient Stability Improvement

    by Yuqi Fu, Zhi Jin Zhang, Martin Ordonez

    A dual-loop frequency-feedforward phase-locked loop (DLFF-PLL) is proposed in this article. The proposed structure achieves angle and frequency tracking without integrator-based loop compensator commonly used in the conventional synchronous reference frame PLL. A dual-loop structure is proposed for tracking frequency and phase, respectively, where a feedforward filter provides the identified frequency from the frequency-tracking loop to the phase-tracking loop to ensure synchronization. The proposed dual-loop structure enables a simple transient-stability-improving technique for grid-connected voltage-sourced converters (VSCs) by placing a saturation block in the frequency feedforward path. Under weak grid conditions, the PLL bandwidth is automatically reduced by saturating the frequency feedforward. As a result, DLFF-PLL with feedforward saturation effectively improves the transient stability of the VSC, e.g., when subjected to large phase and grid impedance jumps.


  • Open Access

    Hypergeometric behavior of metal oxide varistors in DC circuit breakers

    by Yang Liu, Zhi Jin(Justin) Zhang, Kayla Chuong, Zhiyang Jin, Alfonso J. Cruz, Lauren M. Garten, Lukas Graber


  • Interactions of AGC Cyber-Attacks and Remedial Action Schemes in a Two-Area System

    by Abdulmannan Ajabnoor, Zhi Jin Zhang, Maryam Saeedifard, Dominic Groß

    Automatic generation control (AGC) adjusts generator set-points through communication to maintain frequency stability and scheduled power transfer between neighboring areas of power systems. Due to cyber-vulnerabilities in communication networks, the AGC signal is susceptible to attacks, potentially leading to abnormal frequency deviations. This paper analyzes an attack strategy targeting AGC and the factors influencing its success. First, the paper outlines the attacker model and briefly reviews the feedback attack policy. Then, it examines the impact of power system parameters on the likelihood of a successful attack, using a decision tree algorithm, establishing guidelines to identify worst-case scenarios from a system operator’s perspective. Adhering to these guidelines can increase the probability of a successful attack, which is verified using phasor simulation with detailed turbine/governor and protection models. Additionally, the paper examines the attacker threat model, which identifies the attack surface required to steer the system frequency to an unsafe state while avoiding the activation of the remedial action scheme (RAS). If an attacker gains access, they could prevent the tripping of generator circuit breakers, thereby increasing the risk of a system-wide collapse and/or blackout.


  • A Passive-Active Intrusion Detection Scheme for Multiterminal HVdc Grid Line Protection Attacks

    by Zhi Jin Justin Zhang, Matthieu Bloch, Jiuping Pan, Maryam Saeedifard

    Emerging multiterminal dc (MTDC) grids are envisioned to be highly reliant on information communication technology, making them vulnerable to cyber-security threats. In particular, digital substations that house dc-side line fault protection schemes can be compromised by manipulated measurement signals that resemble actual faults, resulting in outages of dc transmission lines. Therefore, it is imperative to defend against such cyber-attacks. To this end, this article proposes an intrusion detection scheme (IDS) for dc line protection schemes. The IDS comprises two stages, passive and active, that operate sequentially. In the first passive stage, the IDS analyzes voltage and current measurements to detect potential cyber-attacks. In the second active stage, the hybrid solid-state dc circuit breaker is actively controlled to identify attacks that evade the passive stage and achieve a moving target defense. The IDS i) conforms with the MTDC grid protection requirements, ii) only utilizes local measurements, and iii) is universal as different algorithms can be incorporated in this scheme while its hybrid passive and active structure stays intact. Off-line simulation and experimental performance evaluation results demonstrate that the IDS is able to detect a variety of cyber-attacks, including the fully-synchronized replay attack (one of the most sophisticated and stealthiest attacks).


  • Overvoltage Suppression and Energy Balancing for Sequential Tripping of Hybrid DC Circuit Breakers

    by Zhi Jin Zhang, Maryam Saeedifard

    During sequential tripping of dc hybrid circuit breakers (HCBs), the energy-absorbing metal-oxide varistors (MOVs) are inserted one after the other rather than simultaneously. This tripping scheme has been demonstrated to be effective in reducing the peak fault current and fault interruption time. However, the voltage overshoots during the sequential tripping process need to be suppressed and the fault energy among the MOVs needs to be balanced. Therefore, this article proposes, first, a simple overvoltage suppression method and second, a modified sequential tripping algorithm for HCBs. The former method is realized by increasing the turn- off gate resistance of the semiconductor devices, for which an analytical expression relating the HCB peak overvoltage and the semiconductor switch's gate resistance is provided. The latter algorithm is able to evenly distribute the MOV energy absorption under different grid conditions with the least number of switching events via a predefined tripping scheme and an energy feedback loop. Verification results from both time-domain simulation and a 1.2 kV circuit breaker hardware corroborate the efficacies of the proposed strategies, which will improve the performance of the sequentially tripped HCBs.


  • Open Access

    Evaluation Tests of Metal Oxide Varistors for DC Circuit Breakers

    by Chunmeng Xu, Andrew Rockhill, Zhi Jin Zhang, Matthew Bosworth, Maryam Saeedifard, Michael Steurer, Peter Zeller, Lukas Graber

    With emerging technologies and products in power semiconductors and ultrafast mechanical switches, direct-current circuit breakers (DCCBs) have been developing rapidly. Yet the metal-oxide varistors (MOVs), being the indispensable DCCB components, are less analyzed and tested so far. Generally, MOVs in DCCBs are used to dissipate energy and limit overvoltage surges during switching events. This emerging application of MOVs calls for new design procedures and evaluation tests to ensure MOV performance under non-standard stresses and repetitive energy pulses. In this paper, online-monitored stress endurance tests are performed on MOVs that are employed in a 12 kV DCCB. Most MOVs have endured the DCCB-derived stresses for about 3500 pulses with little variation in their voltage-current characteristics, while only one fails after 1000 pulse tests and gets damaged by a shunt conductive channel. Different from conventional operating points of MOVs in their voltage-current characteristics, the MOVs in DCCB applications are found to work routinely in the temporary overvoltage (TOV) region with a decreasing TOV current over time. As these behaviors of MOVs are scarcely reported in the literature or covered by their datasheets, this study presents one of the first publicly available endurance test data that address the knowledge gaps about energy-dissipating MOVs in switchgear applications.


  • Lifetime-Based Selection Procedures for DC Circuit Breaker Varistors

    by Zhi Jin Zhang, Matthew Bosworth, Chunmeng Xu, Andrew Rockhill, Peter Zeller, Maryam Saeedifard, Lukas Graber, Michael Steurer

    Varistors are widely used in dc circuit breaker (DCCB) application as fault energy absorption elements, which is not an application the varistors are originally designed for. The fault energy stress adversely impacts the varistor lifetime, thus affecting DCCB reliability and performance. This article presents two methods for choosing the appropriate varistor type and arrangement in a DCCB by linking 1) varistor lifetime and 2) DCCB component- and system-level parameters. The first method uses a set-based design approach with random Latin hypercube sampling to narrow down viable solutions. In comparison, the second method relies on a point-based design approach and proposes an integer programming problem to optimize varistor lifetime. Both procedures are applied to the selection of varistors in 1) a 12 kV DCCB rated for 2-kA nominal current and a peak fault current of 15 kA and 2) a reduced-scale 1.2-kV DCCB hardware prototype, using publicly available varistor data. The article shows the possibility of design for varistor lifetime in DCCB applications, and concludes that both selection procedures provide consistent, reasonable, and verifiable results. However, the results also pinpoint the significant gaps and call for future work on impulse stress versus lifetime relationships for DCCB varistors.