Edis Tunc
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Edis Tunc has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Alexander W. Koch
Institute for Measurement Systems and Sensor Technology, Technical University of Munich, Munich, Germany
1 shared publication- Florian Heilmeier
Chair of Metal Forming and Casting, Technical University of Munich (TUM), 85748 Garching, Germany
1 shared publication - Johannes Roths
Photonics Lab of Munich University of Applied Sciences, Munich, Germany
1 shared publication Klaus Weraneck
Institute for Measurement Systems and Sensor Technology, Technical University of Munich, Munich, Germany
1 shared publication- Markus Lindner
Photonics Laboratory, Munich University of Applied Sciences, Munich, Germany
1 shared publication - Martin Jakobi
Institute for Measurement Systems and Sensor Technology, Technical University of Munich, Theresienstr. 90, 80333 Munich, Germany
1 shared publication
Latest Publications
- 16 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (13) , 5352-5360
Regenerated Bragg Grating Sensor Array for Temperature Measurements During an Aluminum Casting Process
An array of regenerated fiber Bragg gratings (RFBGs) was employed to monitor the temperature distribution during an aluminum cast process. Significant temperature gradients in the cast part were observed during the cooling and solidification period. The direction and velocity of the solidification front was revealed by the temperature data obtained by the RFBGs at different measurement points. A generalized calibration curve was established and applied to the RFBG array, avoiding the need of individual calibration measurements of each sensor element of the array. Temperatures measured using the RFBGs and a thermocouple placed in a reference arm of the mold showed excellent agreements and indicated that no thermal drift of the RFBGs sensor elements occurred during the casting. The RFBG measurements were carried out with only a single fiber, which reduced the amount of lead cables in the melt and hence minimized the sensor-induced disturbances to the casting process. In addition, the limited number of cables enables the RFBG sensors to be deployed in small and complex cast geometries. Multipoint temperature sensors based on RFBG arrays can become important tools to improve the quality of casting processes.
- 16 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (13) , 5352-5360
Regenerated Bragg Grating Sensor Array for Temperature Measurements During an Aluminum Casting Process
An array of regenerated fiber Bragg gratings (RFBGs) was employed to monitor the temperature distribution during an aluminum cast process. Significant temperature gradients in the cast part were observed during the cooling and solidification period. The direction and velocity of the solidification front was revealed by the temperature data obtained by the RFBGs at different measurement points. A generalized calibration curve was established and applied to the RFBG array, avoiding the need of individual calibration measurements of each sensor element of the array. Temperatures measured using the RFBGs and a thermocouple placed in a reference arm of the mold showed excellent agreements and indicated that no thermal drift of the RFBGs sensor elements occurred during the casting. The RFBG measurements were carried out with only a single fiber, which reduced the amount of lead cables in the melt and hence minimized the sensor-induced disturbances to the casting process. In addition, the limited number of cables enables the RFBG sensors to be deployed in small and complex cast geometries. Multipoint temperature sensors based on RFBG arrays can become important tools to improve the quality of casting processes.