LWLie Wang

Lie Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lie Wang has a total of 71 co-authors. Here are the top co-authors by number of shared publications:

  • Ye Zhang

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    10 shared publications
  • Luhe Li

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    9 shared publications
  • Tingting Ye

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center (ChemBIC) Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    8 shared publications
  • Er He

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center (ChemBIC), Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    7 shared publications
  • Jiacheng Wang

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing China

    7 shared publications
  • Yiding Jiao

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing China

    7 shared publications

Latest Publications

  • Open Access

    Moisture-driven discharge chemistry enables the fabrication of highly reversible magnesium–oxygen polymer batteries

    by Ju Lin, Long Jiang, Shifan Zheng, Jing Zhou, Yulong Wan, Lie Wang

    A moisture-driven Mg–O 2 polymer battery enables a new discharge pathway forming Mg 3 (OH) 5 Cl·4H 2 O as the dominant product, achieving highly reversible redox chemistry and record-long cycling stability.


  • A Water-Triggered Fiber-Shaped Magnesium-Air Battery with Prolonged Shelf Life

    by Yulong Wan, Shifan Zheng, Jing Zhou, Long Jiang, Ju Lin, Huangjian Chen, Yonghao Tian, Renbo Deng, Ye Zhang, Lie Wang


  • A Temperature‐Sensing Hydrogel Coating on The Medical Catheter

    by Yiran Li, Dan Li, Jiacheng Wang, Tingting Ye, Qianming Li, Luhe Li, Rui Gao, Yuanzhen Wang, Junye Ren, Fangyan Li, et al.

    Medical surgical catheters are widely used in the medical field for drug delivery or postoperative drainage. However, infections associated with local temperature rise often occur at the catheter‐tissue interface, resulting in irreversible pathological damage, cognitive behavioral abnormalities, or even an increased risk of mortality if not monitored in time. Herein, an in situ temperature‐sensing hydrogel coating on the outer surface of medical surgical catheters for real‐time infection monitoring is developed. The hydrogel coating exhibits a record temperature coefficient of resistance of 2.90% °C−1 and maintains stable in vivo. Besides, the hydrogel layer forms a mechanically compatible catheter‐tissue interface and minimizes the risk of inflammatory responses due to its tissue‐like softness (Young's modulus of 4.24 kPa). By applying it in the early detection of infections in the brain of SD rats, the individual survival rate has increased to 90% with timely intervention.


  • A Mitochondrion‐Inspired Magnesium–Oxygen Biobattery with High Energy Density In Vivo

    by Er He, Junye Ren, Lie Wang, Fangyan Li, Luhe Li, Tingting Ye, Yiding Jiao, Dan Li, Jiacheng Wang, Yuanzhen Wang, et al.

    Implantable batteries are urgently needed as a power source to meet the demands of the next generation of biomedical electronic devices. However, existing implantable batteries suffer from unsatisfactory energy density, hindering the miniaturization of these devices. Here, a mitochondrion‐inspired magnesium–oxygen biobattery that achieves both high energy density and biocompatibility in vivo is reported. The resulting biobattery exhibits a recorded energy density of 2517 Wh L–1/1491 Wh kg–1 based on the total volume/mass of the device in vivo, which is ≈2.5 times higher than the current state‐of‐the‐art, and can adapt to different environments for stable discharges. The volume of the magnesium–oxygen biobattery can be as thin as 0.015 mm3 and can be scaled up to 400 times larger without reducing the energy density. Additionally, it shows a stable biobattery/tissue interface, significantly reducing foreign body reactions. This work presents an effective strategy for the development of high‐performance implantable batteries.


  • High‐Performance Neutral Zinc‐Air Batteries Based on Hybrid Zinc/Carbon Nanotube Fiber Anodes

    by Hao Chen, Luhe Li, Lie Wang, Fangyan Li, Jiacheng Wang, Yiding Jiao, Ye Zhang

    Neutral zinc‐air batteries are considered potential wearable energy storage devices due to their high theoretical energy density, superior safety, and low cost. However, the current performance of neutral zinc‐air batteries is severely influenced by the zinc anodes. The pure zinc anode can be comminuted during charge and discharge cycles due to its unstable electrode structure, resulting in the failure of electrical contact. As a result, the battery exhibits low capacity and short cycle life. In addition, the pure zinc anodes show slow reaction kinetics in neutral electrolytes, which causes the battery to perform low power density and poor energy efficiency. Besides, pure zinc anodes own high bending stiffness, which cannot meet the demands for powering flexible electronics. Herein, a new kind of hybrid zinc/carbon nanotube fiber anode with a stable electrode structure, high reaction activity, as well as high flexibility is proposed to produce high‐performance neutral zinc‐air batteries. The fabricated fiber battery showed a high specific capacity and maximum power density of 645.3 mAh g−1 and 615.8 mW g−1, respectively. Furthermore, a high energy efficiency of 71% is achieved, the highest among the reported neutral zinc‐air batteries. The entire fiber battery is highly flexible, highlighting its potential for wearable energy storage applications.


  • A Core–Sheath Sensing Yarn‐Based Electrochemical Fabric System for Powerful Sweat Capture and Stable Sensing

    by Lie Wang, Jiang Lu, Qianming Li, Luhe Li, Er He, Yiding Jiao, Tingting Ye, Ye Zhang

    Wearable sweat sensing technologies have received wide attention for personalized health monitoring with continuous and molecular‐level insight in a noninvasive manner. However, it remains significantly challenging to simultaneously capture a sufficient volume of sweat and achieve stable contact between electrodes and sweat, especially in a relatively mild sweating condition. Herein, a wearable electrochemical fabric sensor is developed by embroidering diversified sensing yarns with a multi‐ply cotton sheath and carbon nanotube‐based sensing fiber core into a super‐hydrophobic fabric substrate. The device allows for sweat enrichment among the core–sheath sensing yarn and reduce ineffective diffusion, thus remarkably increasing the sweat capture efficiency. As a result, only 0.5 µL of sweat is needed to achieve stable circuit connectivity, 1/20 of the lowest volume reported to date. The device also maintains a highly durable sensing performance, obtained even during dynamic deformation processes such as bending, twisting, and shaking. It can be further designed into an integrated sports shirt system, which can perform real‐time monitoring of multiple chemical information (e.g., glucose, Na+, K+, and pH) of sweat for users at the states of both intense exercise conditions such as badminton and relatively mild conditions like walking and eating.


  • A Tissue‐Like Soft All‐Hydrogel Battery

    by Tingting Ye, Jiacheng Wang, Yiding Jiao, Luhe Li, Er He, Lie Wang, Yiran Li, Yanjing Yun, Dan Li, Jiang Lu, et al.

    To develop wearable and implantable bioelectronics accommodating the dynamic and uneven biological tissues and reducing undesired immune responses, it is critical to adopt batteries with matched mechanical properties with tissues as power sources. However, the batteries available cannot reach the softness of tissues due to the high Young's moduli of components (e.g., metals, carbon materials, conductive polymers, or composite materials). The fabrication of tissue‐like soft batteries thus remains a challenge. Here, the first ultrasoft batteries totally based on hydrogels are reported. The ultrasoft batteries exhibit Young's moduli of 80 kPa, perfectly matching skin and organs (e.g., heart). The high specific capacities of 82 mAh g−1 in all‐hydrogel lithium‐ion batteries and 370 mAh g−1 in all‐hydrogel zinc‐ion batteries at a current density of 0.5 A g−1 are achieved. Both high stability and biocompatibility of the all‐hydrogel batteries have been demonstrated upon the applications of wearable and implantable. This work illuminates a pathway for designing power sources for wearable and implantable electronics with matched mechanical properties.


  • Designing Porous Antifouling Interfaces for High‐Power Implantable Biofuel Cell

    by Lie Wang, Er He, Rui Gao, Xiaotong Wu, Anwei Zhou, Jiang Lu, Tiancheng Zhao, Jiaxin Li, Yanjing Yun, Luhe Li, et al.

    Biofuel cells that can convert the chemical energy of biomass such as glucose into electricity are expected to continuously obtain energy from living organisms and solve bottlenecks of energy supply for implanted electronics. However, the use of biofuel cells is limited mainly by the sharp drop in performance after implanting in living organisms caused by biofouling and electrode surface inactivation. Herein, a simple and effective strategy to overcome these problems by designing a porous antifouling interface on biofuel cells, is demonstrated. It resists the biofouling from body fluid while sustaining reactant penetration, and also enhances immobilization of enzymes. As a result, the biofuel cell can maintain almost 100% performance after implanting in living organisms, and a maximal output power of 76.6 mW cm‐3 is achieved in vivo, which is ≈96 times of the highest performance reported to date. This strategy is universal and can be extended to the other electronic devices such as electrochemical sensors, which presents a new avenue for developing high‐performance implanted electronics.


  • Engineering Polymer Glue towards 90% Zinc Utilization for 1000 Hours to Make High‐Performance Zn‐Ion Batteries

    by Yiding Jiao, Fangyan Li, Xin Jin, Qingsong Lei, Luhe Li, Lie Wang, Tingting Ye, Er He, Jiacheng Wang, Hao Chen, et al.

    Zinc (Zn) metal is considered the promising anode for “post‐lithium” energy storage due to its high volumetric capacity, low redox potential, abundant reserve, and low cost. However, extravagant Zn is required in present Zn batteries, featuring low Zn utilization rate and device‐scale energy/power densities far below theoretical values. The limited reversibility of Zn metal is attributed to the spontaneous parasitic reactions of Zn with aqueous electrolytes, that is, corrosion with water, passive by‐product formation, and dendrite growth. Here, a new ion‐selective polymer glue coated on Zn anode is designed, isolating the Zn anode from the electrolyte by blocking water diffusion while allowing rapid Zn2+ ion migration and facilitating uniform electrodeposition. Hence, a record‐high Zn utilization of 90% is realized for 1000 h at high current densities, in sharp contrast to much poorer cyclability (usually < 200 h) at lower Zn utilization (50–85%) reported to date. When matched with the vanadium‐based cathode, the resulting Zn‐ion battery exhibited an ultrahigh device‐scale energy density of 228 Wh kg−1, comparable to commercial lithium‐ion batteries.


  • High‐Energy‐Density Magnesium‐Air Battery Based on Dual‐Layer Gel Electrolyte

    by Luhe Li, Hao Chen, Er He, Lie Wang, Tingting Ye, Jiang Lu, Yiding Jiao, Jiacheng Wang, Rui Gao, Huisheng Peng, et al.

    Mg‐air batteries are explored as the next‐generation power systems for wearable and implantable electronics as they could work stably in neutral electrolytes and are also biocompatible. However, high corrosion rate and low utilization of Mg anode largely impair the performance of Mg‐air battery with low discharge voltage, poor specific capacity and low energy density. Here, to the best of our knowledge, we first report a dual‐layer gel electrolyte to simultaneously solve the above two problems by preventing the corrosion of Mg anode and the production of dense passive layer, respectively. The resulting Mg‐air batteries produced an average specific capacity of 2190 mAh g−1 based on the total Mg anode (99.3 % utilization rate of Mg anode) and energy density of 2282 Wh kg−1 based on the total anode and air electrode, both of which are the highest among the reported Mg‐air batteries. Besides, our Mg‐air batteries could be made into a fiber shape, and they were flexible to work stably under various deformations such as bending and twisting.