YJYiding Jiao

Yiding Jiao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yiding Jiao has a total of 100 co-authors. Here are the top co-authors by number of shared publications:

  • Ye Zhang

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    17 shared publications
  • Jiacheng Wang

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing China

    9 shared publications
  • Er He

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center (ChemBIC), Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    8 shared publications
  • Lie Wang

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center (ChemBIC) Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    7 shared publications
  • Luhe Li

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    7 shared publications
  • Tingting Ye

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center (ChemBIC) Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    7 shared publications

Latest Publications

  • Open Access

    Growing Fiber Sensors Enable Continuous In Vivo Monitoring of Plant Hormones

    by Kuangyi Zou, Jiacheng Wang, Xiangyi Li, Sicheng Huang, Fei Zhou, Hongyu Chen, Yiding Jiao, Qianming Li, Yiran Li, Er He, et al.

    Plant stress during growth, caused by extreme environments and biotic attacks, threatens global biodiversity and crop production, necessitating urgent elucidation of plant adaptation mechanisms. Endogenous hormones of plant growth serve as master regulators and earliest indicators of stress adaptation, making it crucial to monitor their dynamics continuously. However, existing methods, including chromatography and electrochemical probes, fail because of their mismatch with the irreversible and plastic nature of plant growth. Here, we unexpectedly find a growing fiber sensor based on an electrode consisting of a dynamic polymer network infiltrated with liquid metal, termed metalgel. The sensor undergoes irreversible elongation ∼up to 10 times its original length under just 3.2 kPa tensile stress, at least 2 orders of magnitude lower than existing electronic conductive systems, thus achieving synchronous deformation with plant growth without inducing mechanical damage or hormonal disturbances. Hormone dynamics and relevant signaling pathways during plant growth in response to pathogen infection, salt stress, and even extreme ultraviolet radiation are thus revealed by the sensor. This work provides quantitative insights into plant stress resilience mechanisms and offers a feasible route to alleviate the food and ecological crises.

  • Light-Controlled Battery-Integrated Nerve Conduit for Peripheral Nerve Pain Management

    by Er He, Haidong Wang, Fangyan Li, Tingting Ye, Yiding Jiao, Luhe Li, Jie Song, Hanting Zhang, Shuo Yang, Jiacheng Wang, et al.

    Pain management typically relies on pharmaceutical treatments, which frequently carry a risk of dependence and exhibit limited efficacy. The utilization of implantable electroceuticals is a developing field that shows great promise as an alternative. However, current devices are incapable of providing long-term, reliable electrical stimulation in situ. Here, we present a light-controlled, battery-integrated nerve conduit with tunable output, enabled by the light-induced reversible relocation of water molecules in the electrolyte. Precise modulation of the nerve conduit's electrical output is realized through the modulation of light intensity and pulsing protocols. The design of the device eliminates the need for external control circuitry, thus minimizing the size and maximizing energy efficiency. Consequently, the nerve conduit possesses a total volume of just 26 mm3. This compact and conformal design enables direct nerve interfacing, and hence facilitates precise and programmable neuromodulation in situ. Moreover, in vivo studies demonstrate its efficacy in the inhibition of peripheral nerve pain for a period of up to 30 days.


  • Atmospheric Water Harvesting Enables High-Performance Metal–Air Batteries

    by Hanting Zhang, Er He, Fangyan Li, Shuo Yang, Yiding Jiao, Chenyu Bai, Yiran Li, Yuanzhen Wang, Haidong Wang, Jiacheng Wang, et al.

  • A New Metalgel Current Collector for Simultaneous Rapid and Stable Zinc Electrochemistry

    by Fangyan Li, Er He, Yiding Jiao, Shuo Yang, Jiacheng Wang, Haidong Wang, Xinyu Liu, Xusong Li, Hanting Zhang, Yuanzhen Wang, et al.

    Achieving both high‐rate capability and long‐term cycling stability in zinc anode remains challenging due to the fundamental trade‐off. Fast kinetics require maximum interfacial area for charge transfer, while stability demands minimal zinc/electrolyte contact to suppress parasitic reactions and dendrite growth. However, in previous studies, zinc deposited at the electrode/electrolyte interface, leading to limited lifetimes (≤ 1200 h at a utilization ratio of ≥ 60%) and high overpotentials (≥ 480 mV at 50 mA·cm −2 ). Here, we design a new metalgel current collector to effectively resolve the above limitation. The metalgel comprises a biphasic gallium–indium–zinc continuum immobilized within a 3D polymer network, establishing both ion and electron conduction pathways that maximize the electrochemically active interface. The biphasic gallium–indium–zinc contains solid metallic zinc dispersed within the liquid gallium–indium–zinc alloy phase, enabling inward zinc deposition/stripping via a reversible dissolution–precipitation alloying process. This inward‐deposition/stripping minimizes zinc/electrolyte contact and suppresses parasitic reactions and dendrite formation, enabling zinc anodes to achieve over 4300 h of stable cycling at 80% zinc utilization ratio and maintain only 156.6 mV overpotential at an ultrahigh current density of 100 mA·cm −2 . By decoupling interfacial kinetics from interfacial instabilities, this work presents a new paradigm for high‐performance metal batteries.


  • Metalgel Fiber with Excellent Electrical and Mechanical Properties

    by Yuanzhen Wang, Yiding Jiao, Jiacheng Wang, Hanting Zhang, Tingting Ye, Jiang Lu, Er He, Luhe Li, Jie Song, Chenyu Bai, et al.

    With the rapid advancement of soft electronics, particularly the rise of fiber electronics and smart textiles, there is an urgent need to develop high-performance fiber materials with both excellent electrical and mechanical properties. However, existing fiber materials including metal fibers, carbon-based fibers, intrinsically conductive polymer fibers, and composite fibers struggle to simultaneously meet the requirements. Here, we introduce a metalgel fiber with a unique structure. In metalgel fibers, liquid metal forms a continuum, extending throughout the entire volume of nanostructured fucoidan polymer networks, which are immobilized by electrostatic interactions. The distinctive structure imparts the fiber with metallic conductivity (2.8 × 106 S·m-1), softness (Young's modulus of 1.8 MPa), and stable electromechanical coupling properties (resistance change <5% after 20,000 times pressing, stretching, bending, and twisting cycles). The metalgel fibers were woven into multifunctional smart textiles, highlighting their potential for practical applications.


  • Implantable Batteries for Bioelectronics

    by Yiding Jiao, Er He, Tingting Ye, Yuanzhen Wang, Haotian Yin, Ye Zhang


  • Electrochemical Activation Inducing Rocksalt‐to‐Spinel Transformation for Prolonged Service Life of LiMn 2 O 4 Cathodes

    by Fangyan Li, Yiding Jiao, Shuo Yang, Wei Mao, Qiantu Tao, Chenyu Bai, Er He, Luhe Li, Tingting Ye, Yiran Li, et al.

    LiMn 2 O 4 spinel is emerging as a promising cathode material for lithium‐ion batteries, largely due to its open framework that facilitates Li + diffusion and excellent rate performance. However, the charge–discharge cycling of the LiMn 2 O 4 cathode leads to severe structural degradation and rapid capacity decay. Here, an electrochemical activation strategy is introduced, employing a facile galvano‐potentiostatic charging operation, to restore the lost capacity of LiMn 2 O 4 cathode without damaging the battery configuration. With an electrochemical activation strategy, the cycle life of the LiMn 2 O 4 cathode is extended from an initial 1500 to an impressive 14 000 cycles at a 5C rate with Li metal as the anode, while increasing the total discharge energy by ten times. Remarkably, the electrochemical activation enhances the diffusion kinetics of Li + , with the diffusion coefficient experiencing a 37.2% increase. Further investigation reveals that this improvement in capacity and diffusion kinetics results from a transformation of the redox‐inert LiMnO 2 rocksalt layer on the surface of degraded cathodes back into active spinel. This transformation is confirmed through electron microscopy and corroborated by density functional theory simulations. Moreover, the viability of this electrochemical activation strategy has been demonstrated in pouch cell configurations with Li metal as the anode, underscoring its potential for broader application.


  • A Highly Selective Implantable Electrochemical Fiber Sensor for Real-Time Monitoring of Blood Homovanillic Acid

    by Kuangyi Zou, Qianming Li, Dan Li, Yiding Jiao, Lie Wang, Luhe Li, Jiacheng Wang, Yiran Li, Rui Gao, Fangyan Li, et al.

    Homovanillic acid (HVA) is a major dopamine metabolite, and blood HVA is considered as central nervous system (CNS) dopamine biomarker, which reflects the progression of dopamine-associated CNS diseases and the behavioral response to therapeutic drugs. However, facing blood various active substances interference, particularly structurally similar catecholamines and their metabolites, real-time and accurate monitoring of blood HVA remains a challenge. Herein, a highly selective implantable electrochemical fiber sensor based on a molecularly imprinted polymer is reported to accurately monitor HVA in vivo. The sensor exhibits high selectivity, with a response intensity to HVA 12.6 times greater than that of catecholamines and their metabolites, achieving 97.8% accuracy in vivo. The sensor injected into the rat caudal vein tracked the real-time changes of blood HVA, which paralleled the brain dopamine fluctuations and indicated the behavioral response to dopamine increase. This study provides a universal design strategy for improving the selectivity of implantable electrochemical sensors.


  • A Temperature‐Sensing Hydrogel Coating on The Medical Catheter

    by Yiran Li, Dan Li, Jiacheng Wang, Tingting Ye, Qianming Li, Luhe Li, Rui Gao, Yuanzhen Wang, Junye Ren, Fangyan Li, et al.

    Medical surgical catheters are widely used in the medical field for drug delivery or postoperative drainage. However, infections associated with local temperature rise often occur at the catheter‐tissue interface, resulting in irreversible pathological damage, cognitive behavioral abnormalities, or even an increased risk of mortality if not monitored in time. Herein, an in situ temperature‐sensing hydrogel coating on the outer surface of medical surgical catheters for real‐time infection monitoring is developed. The hydrogel coating exhibits a record temperature coefficient of resistance of 2.90% °C−1 and maintains stable in vivo. Besides, the hydrogel layer forms a mechanically compatible catheter‐tissue interface and minimizes the risk of inflammatory responses due to its tissue‐like softness (Young's modulus of 4.24 kPa). By applying it in the early detection of infections in the brain of SD rats, the individual survival rate has increased to 90% with timely intervention.


  • A Mitochondrion‐Inspired Magnesium–Oxygen Biobattery with High Energy Density In Vivo

    by Er He, Junye Ren, Lie Wang, Fangyan Li, Luhe Li, Tingting Ye, Yiding Jiao, Dan Li, Jiacheng Wang, Yuanzhen Wang, et al.

    Implantable batteries are urgently needed as a power source to meet the demands of the next generation of biomedical electronic devices. However, existing implantable batteries suffer from unsatisfactory energy density, hindering the miniaturization of these devices. Here, a mitochondrion‐inspired magnesium–oxygen biobattery that achieves both high energy density and biocompatibility in vivo is reported. The resulting biobattery exhibits a recorded energy density of 2517 Wh L–1/1491 Wh kg–1 based on the total volume/mass of the device in vivo, which is ≈2.5 times higher than the current state‐of‐the‐art, and can adapt to different environments for stable discharges. The volume of the magnesium–oxygen biobattery can be as thin as 0.015 mm3 and can be scaled up to 400 times larger without reducing the energy density. Additionally, it shows a stable biobattery/tissue interface, significantly reducing foreign body reactions. This work presents an effective strategy for the development of high‐performance implantable batteries.