Jiacheng Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jiacheng Wang has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Ye Zhang
National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China
11 shared publications - Yiding Jiao
National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing China
9 shared publications - Er He
National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center (ChemBIC), Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China
8 shared publications - Fangyan Li
National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing China
7 shared publications - Lie Wang
National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center (ChemBIC) Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China
7 shared publications - Luhe Li
National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China
7 shared publications
Latest Publications
- Open Access
- 28 August 2026
- Published by Wiley in Advanced Materials
- Vol. 38 (59) , e74856
Growing Fiber Sensors Enable Continuous In Vivo Monitoring of Plant Hormones
Plant stress during growth, caused by extreme environments and biotic attacks, threatens global biodiversity and crop production, necessitating urgent elucidation of plant adaptation mechanisms. Endogenous hormones of plant growth serve as master regulators and earliest indicators of stress adaptation, making it crucial to monitor their dynamics continuously. However, existing methods, including chromatography and electrochemical probes, fail because of their mismatch with the irreversible and plastic nature of plant growth. Here, we unexpectedly find a growing fiber sensor based on an electrode consisting of a dynamic polymer network infiltrated with liquid metal, termed metalgel. The sensor undergoes irreversible elongation ∼up to 10 times its original length under just 3.2 kPa tensile stress, at least 2 orders of magnitude lower than existing electronic conductive systems, thus achieving synchronous deformation with plant growth without inducing mechanical damage or hormonal disturbances. Hormone dynamics and relevant signaling pathways during plant growth in response to pathogen infection, salt stress, and even extreme ultraviolet radiation are thus revealed by the sensor. This work provides quantitative insights into plant stress resilience mechanisms and offers a feasible route to alleviate the food and ecological crises.
- 28 August 2026
- Published by Wiley in Advanced Materials
- Vol. 38 (59) , e74856
Open AccessGrowing Fiber Sensors Enable Continuous In Vivo Monitoring of Plant Hormones
Plant stress during growth, caused by extreme environments and biotic attacks, threatens global biodiversity and crop production, necessitating urgent elucidation of plant adaptation mechanisms. Endogenous hormones of plant growth serve as master regulators and earliest indicators of stress adaptation, making it crucial to monitor their dynamics continuously. However, existing methods, including chromatography and electrochemical probes, fail because of their mismatch with the irreversible and plastic nature of plant growth. Here, we unexpectedly find a growing fiber sensor based on an electrode consisting of a dynamic polymer network infiltrated with liquid metal, termed metalgel. The sensor undergoes irreversible elongation ∼up to 10 times its original length under just 3.2 kPa tensile stress, at least 2 orders of magnitude lower than existing electronic conductive systems, thus achieving synchronous deformation with plant growth without inducing mechanical damage or hormonal disturbances. Hormone dynamics and relevant signaling pathways during plant growth in response to pathogen infection, salt stress, and even extreme ultraviolet radiation are thus revealed by the sensor. This work provides quantitative insights into plant stress resilience mechanisms and offers a feasible route to alleviate the food and ecological crises.
A New Metalgel Current Collector for Simultaneous Rapid and Stable Zinc Electrochemistry
Achieving both high‐rate capability and long‐term cycling stability in zinc anode remains challenging due to the fundamental trade‐off. Fast kinetics require maximum interfacial area for charge transfer, while stability demands minimal zinc/electrolyte contact to suppress parasitic reactions and dendrite growth. However, in previous studies, zinc deposited at the electrode/electrolyte interface, leading to limited lifetimes (≤ 1200 h at a utilization ratio of ≥ 60%) and high overpotentials (≥ 480 mV at 50 mA·cm −2 ). Here, we design a new metalgel current collector to effectively resolve the above limitation. The metalgel comprises a biphasic gallium–indium–zinc continuum immobilized within a 3D polymer network, establishing both ion and electron conduction pathways that maximize the electrochemically active interface. The biphasic gallium–indium–zinc contains solid metallic zinc dispersed within the liquid gallium–indium–zinc alloy phase, enabling inward zinc deposition/stripping via a reversible dissolution–precipitation alloying process. This inward‐deposition/stripping minimizes zinc/electrolyte contact and suppresses parasitic reactions and dendrite formation, enabling zinc anodes to achieve over 4300 h of stable cycling at 80% zinc utilization ratio and maintain only 156.6 mV overpotential at an ultrahigh current density of 100 mA·cm −2 . By decoupling interfacial kinetics from interfacial instabilities, this work presents a new paradigm for high‐performance metal batteries.
A New Metalgel Current Collector for Simultaneous Rapid and Stable Zinc Electrochemistry
Achieving both high‐rate capability and long‐term cycling stability in zinc anode remains challenging due to the fundamental trade‐off. Fast kinetics require maximum interfacial area for charge transfer, while stability demands minimal zinc/electrolyte contact to suppress parasitic reactions and dendrite growth. However, in previous studies, zinc deposited at the electrode/electrolyte interface, leading to limited lifetimes (≤ 1200 h at a utilization ratio of ≥ 60%) and high overpotentials (≥ 480 mV at 50 mA·cm −2 ). Here, we design a new metalgel current collector to effectively resolve the above limitation. The metalgel comprises a biphasic gallium–indium–zinc continuum immobilized within a 3D polymer network, establishing both ion and electron conduction pathways that maximize the electrochemically active interface. The biphasic gallium–indium–zinc contains solid metallic zinc dispersed within the liquid gallium–indium–zinc alloy phase, enabling inward zinc deposition/stripping via a reversible dissolution–precipitation alloying process. This inward‐deposition/stripping minimizes zinc/electrolyte contact and suppresses parasitic reactions and dendrite formation, enabling zinc anodes to achieve over 4300 h of stable cycling at 80% zinc utilization ratio and maintain only 156.6 mV overpotential at an ultrahigh current density of 100 mA·cm −2 . By decoupling interfacial kinetics from interfacial instabilities, this work presents a new paradigm for high‐performance metal batteries.
- 24 October 2024
- Published by Wiley in Advanced Materials
- Vol. 36 (49) , e2409137
A Metalgel with Liquid Metal Continuum Immobilized in Polymer Network
Gels are formed by fluids that expand throughout the whole volume of 3D polymer networks. To unlock unprecedented properties, exploring new fluids immobilized in polymer networks is crucial. Here, a new liquid metal‐polymer gel material termed “metalgel” is introduced via fluid replacement strategy, featuring 92.40% vol liquid metal fluid as a continuum immobilized by interconnected nanoscale polymer network. The unique structure endows metalgel with high electrical conductivity (up to 3.18 × 10 6 S·m ‒1 ), tissue‐like softness (Young's modulus as low as 70 kPa), and low gas permeability (4.50 × 10 ‒22 m 2 ·s ‒1 ·Pa ‒1 ). Besides, metalgel demonstrates electrical stability under extreme deformations, such as being run over by a 4.5‐metric‐tonne truck, and maintains its integrity in various environments for up to 180 days. The immobilization of high‐volume‐fraction liquid metal fluid is realized by electrostatic interactions is further revealed. Potential applications for metalgel are diverse and include soft electromagnetic shielding, hermetic sealing, and stimulating/sensing electrodes in implantable bioelectronics, underscoring its broad applicability.
- 24 October 2024
- Published by Wiley in Advanced Materials
- Vol. 36 (49) , e2409137
A Metalgel with Liquid Metal Continuum Immobilized in Polymer Network
Gels are formed by fluids that expand throughout the whole volume of 3D polymer networks. To unlock unprecedented properties, exploring new fluids immobilized in polymer networks is crucial. Here, a new liquid metal‐polymer gel material termed “metalgel” is introduced via fluid replacement strategy, featuring 92.40% vol liquid metal fluid as a continuum immobilized by interconnected nanoscale polymer network. The unique structure endows metalgel with high electrical conductivity (up to 3.18 × 10 6 S·m ‒1 ), tissue‐like softness (Young's modulus as low as 70 kPa), and low gas permeability (4.50 × 10 ‒22 m 2 ·s ‒1 ·Pa ‒1 ). Besides, metalgel demonstrates electrical stability under extreme deformations, such as being run over by a 4.5‐metric‐tonne truck, and maintains its integrity in various environments for up to 180 days. The immobilization of high‐volume‐fraction liquid metal fluid is realized by electrostatic interactions is further revealed. Potential applications for metalgel are diverse and include soft electromagnetic shielding, hermetic sealing, and stimulating/sensing electrodes in implantable bioelectronics, underscoring its broad applicability.
Electrochemical Activation Inducing Rocksalt‐to‐Spinel Transformation for Prolonged Service Life of LiMn 2 O 4 Cathodes
LiMn 2 O 4 spinel is emerging as a promising cathode material for lithium‐ion batteries, largely due to its open framework that facilitates Li + diffusion and excellent rate performance. However, the charge–discharge cycling of the LiMn 2 O 4 cathode leads to severe structural degradation and rapid capacity decay. Here, an electrochemical activation strategy is introduced, employing a facile galvano‐potentiostatic charging operation, to restore the lost capacity of LiMn 2 O 4 cathode without damaging the battery configuration. With an electrochemical activation strategy, the cycle life of the LiMn 2 O 4 cathode is extended from an initial 1500 to an impressive 14 000 cycles at a 5C rate with Li metal as the anode, while increasing the total discharge energy by ten times. Remarkably, the electrochemical activation enhances the diffusion kinetics of Li + , with the diffusion coefficient experiencing a 37.2% increase. Further investigation reveals that this improvement in capacity and diffusion kinetics results from a transformation of the redox‐inert LiMnO 2 rocksalt layer on the surface of degraded cathodes back into active spinel. This transformation is confirmed through electron microscopy and corroborated by density functional theory simulations. Moreover, the viability of this electrochemical activation strategy has been demonstrated in pouch cell configurations with Li metal as the anode, underscoring its potential for broader application.
Electrochemical Activation Inducing Rocksalt‐to‐Spinel Transformation for Prolonged Service Life of LiMn 2 O 4 Cathodes
LiMn 2 O 4 spinel is emerging as a promising cathode material for lithium‐ion batteries, largely due to its open framework that facilitates Li + diffusion and excellent rate performance. However, the charge–discharge cycling of the LiMn 2 O 4 cathode leads to severe structural degradation and rapid capacity decay. Here, an electrochemical activation strategy is introduced, employing a facile galvano‐potentiostatic charging operation, to restore the lost capacity of LiMn 2 O 4 cathode without damaging the battery configuration. With an electrochemical activation strategy, the cycle life of the LiMn 2 O 4 cathode is extended from an initial 1500 to an impressive 14 000 cycles at a 5C rate with Li metal as the anode, while increasing the total discharge energy by ten times. Remarkably, the electrochemical activation enhances the diffusion kinetics of Li + , with the diffusion coefficient experiencing a 37.2% increase. Further investigation reveals that this improvement in capacity and diffusion kinetics results from a transformation of the redox‐inert LiMnO 2 rocksalt layer on the surface of degraded cathodes back into active spinel. This transformation is confirmed through electron microscopy and corroborated by density functional theory simulations. Moreover, the viability of this electrochemical activation strategy has been demonstrated in pouch cell configurations with Li metal as the anode, underscoring its potential for broader application.
- 22 November 2023
- Published by Wiley in Advanced Functional Materials
- Vol. 34 (10)
A Temperature‐Sensing Hydrogel Coating on The Medical Catheter
Medical surgical catheters are widely used in the medical field for drug delivery or postoperative drainage. However, infections associated with local temperature rise often occur at the catheter‐tissue interface, resulting in irreversible pathological damage, cognitive behavioral abnormalities, or even an increased risk of mortality if not monitored in time. Herein, an in situ temperature‐sensing hydrogel coating on the outer surface of medical surgical catheters for real‐time infection monitoring is developed. The hydrogel coating exhibits a record temperature coefficient of resistance of 2.90% °C−1 and maintains stable in vivo. Besides, the hydrogel layer forms a mechanically compatible catheter‐tissue interface and minimizes the risk of inflammatory responses due to its tissue‐like softness (Young's modulus of 4.24 kPa). By applying it in the early detection of infections in the brain of SD rats, the individual survival rate has increased to 90% with timely intervention.
- 22 November 2023
- Published by Wiley in Advanced Functional Materials
- Vol. 34 (10)
A Temperature‐Sensing Hydrogel Coating on The Medical Catheter
Medical surgical catheters are widely used in the medical field for drug delivery or postoperative drainage. However, infections associated with local temperature rise often occur at the catheter‐tissue interface, resulting in irreversible pathological damage, cognitive behavioral abnormalities, or even an increased risk of mortality if not monitored in time. Herein, an in situ temperature‐sensing hydrogel coating on the outer surface of medical surgical catheters for real‐time infection monitoring is developed. The hydrogel coating exhibits a record temperature coefficient of resistance of 2.90% °C−1 and maintains stable in vivo. Besides, the hydrogel layer forms a mechanically compatible catheter‐tissue interface and minimizes the risk of inflammatory responses due to its tissue‐like softness (Young's modulus of 4.24 kPa). By applying it in the early detection of infections in the brain of SD rats, the individual survival rate has increased to 90% with timely intervention.
- 10 October 2023
- Published by Wiley in Advanced Materials
- Vol. 35 (45) , e2304141
A Mitochondrion‐Inspired Magnesium–Oxygen Biobattery with High Energy Density In Vivo
Implantable batteries are urgently needed as a power source to meet the demands of the next generation of biomedical electronic devices. However, existing implantable batteries suffer from unsatisfactory energy density, hindering the miniaturization of these devices. Here, a mitochondrion‐inspired magnesium–oxygen biobattery that achieves both high energy density and biocompatibility in vivo is reported. The resulting biobattery exhibits a recorded energy density of 2517 Wh L–1/1491 Wh kg–1 based on the total volume/mass of the device in vivo, which is ≈2.5 times higher than the current state‐of‐the‐art, and can adapt to different environments for stable discharges. The volume of the magnesium–oxygen biobattery can be as thin as 0.015 mm3 and can be scaled up to 400 times larger without reducing the energy density. Additionally, it shows a stable biobattery/tissue interface, significantly reducing foreign body reactions. This work presents an effective strategy for the development of high‐performance implantable batteries.
- 10 October 2023
- Published by Wiley in Advanced Materials
- Vol. 35 (45) , e2304141
A Mitochondrion‐Inspired Magnesium–Oxygen Biobattery with High Energy Density In Vivo
Implantable batteries are urgently needed as a power source to meet the demands of the next generation of biomedical electronic devices. However, existing implantable batteries suffer from unsatisfactory energy density, hindering the miniaturization of these devices. Here, a mitochondrion‐inspired magnesium–oxygen biobattery that achieves both high energy density and biocompatibility in vivo is reported. The resulting biobattery exhibits a recorded energy density of 2517 Wh L–1/1491 Wh kg–1 based on the total volume/mass of the device in vivo, which is ≈2.5 times higher than the current state‐of‐the‐art, and can adapt to different environments for stable discharges. The volume of the magnesium–oxygen biobattery can be as thin as 0.015 mm3 and can be scaled up to 400 times larger without reducing the energy density. Additionally, it shows a stable biobattery/tissue interface, significantly reducing foreign body reactions. This work presents an effective strategy for the development of high‐performance implantable batteries.
- 28 August 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (24)
High‐Performance Neutral Zinc‐Air Batteries Based on Hybrid Zinc/Carbon Nanotube Fiber Anodes
Neutral zinc‐air batteries are considered potential wearable energy storage devices due to their high theoretical energy density, superior safety, and low cost. However, the current performance of neutral zinc‐air batteries is severely influenced by the zinc anodes. The pure zinc anode can be comminuted during charge and discharge cycles due to its unstable electrode structure, resulting in the failure of electrical contact. As a result, the battery exhibits low capacity and short cycle life. In addition, the pure zinc anodes show slow reaction kinetics in neutral electrolytes, which causes the battery to perform low power density and poor energy efficiency. Besides, pure zinc anodes own high bending stiffness, which cannot meet the demands for powering flexible electronics. Herein, a new kind of hybrid zinc/carbon nanotube fiber anode with a stable electrode structure, high reaction activity, as well as high flexibility is proposed to produce high‐performance neutral zinc‐air batteries. The fabricated fiber battery showed a high specific capacity and maximum power density of 645.3 mAh g−1 and 615.8 mW g−1, respectively. Furthermore, a high energy efficiency of 71% is achieved, the highest among the reported neutral zinc‐air batteries. The entire fiber battery is highly flexible, highlighting its potential for wearable energy storage applications.
- 28 August 2023
- Published by Wiley in Advanced Materials Technologies
- Vol. 8 (24)
High‐Performance Neutral Zinc‐Air Batteries Based on Hybrid Zinc/Carbon Nanotube Fiber Anodes
Neutral zinc‐air batteries are considered potential wearable energy storage devices due to their high theoretical energy density, superior safety, and low cost. However, the current performance of neutral zinc‐air batteries is severely influenced by the zinc anodes. The pure zinc anode can be comminuted during charge and discharge cycles due to its unstable electrode structure, resulting in the failure of electrical contact. As a result, the battery exhibits low capacity and short cycle life. In addition, the pure zinc anodes show slow reaction kinetics in neutral electrolytes, which causes the battery to perform low power density and poor energy efficiency. Besides, pure zinc anodes own high bending stiffness, which cannot meet the demands for powering flexible electronics. Herein, a new kind of hybrid zinc/carbon nanotube fiber anode with a stable electrode structure, high reaction activity, as well as high flexibility is proposed to produce high‐performance neutral zinc‐air batteries. The fabricated fiber battery showed a high specific capacity and maximum power density of 645.3 mAh g−1 and 615.8 mW g−1, respectively. Furthermore, a high energy efficiency of 71% is achieved, the highest among the reported neutral zinc‐air batteries. The entire fiber battery is highly flexible, highlighting its potential for wearable energy storage applications.
- Open Access
Personalizing Federated Medical Image Segmentation via Local Calibration
Medical image segmentation under federated learning (FL) is a promising direction by allowing multiple clinical sites to collaboratively learn a global model without centralizing datasets. However, using a single model to adapt to various data distributions from different sites is extremely challenging. Personalized FL tackles this issue by only utilizing partial model parameters shared from global server, while keeping the rest to adapt to its own data distribution in the local training of each site. However, most existing methods concentrate on the partial parameter splitting, while do not consider the \textit{inter-site in-consistencies} during the local training, which in fact can facilitate the knowledge communication over sites to benefit the model learning for improving the local accuracy. In this paper, we propose a personalized federated framework with \textbf{L}ocal \textbf{C}alibration (LC-Fed), to leverage the inter-site in-consistencies in both \textit{feature- and prediction- levels} to boost the segmentation. Concretely, as each local site has its alternative attention on the various features, we first design the contrastive site embedding coupled with channel selection operation to calibrate the encoded features. Moreover, we propose to exploit the knowledge of prediction-level in-consistency to guide the personalized modeling on the ambiguous regions, e.g., anatomical boundaries. It is achieved by computing a disagreement-aware map to calibrate the prediction. Effectiveness of our method has been verified on three medical image segmentation tasks with different modalities, where our method consistently shows superior performance to the state-of-the-art personalized FL methods. Code is available at https://github.com/jcwang123/FedLC.
Open AccessPersonalizing Federated Medical Image Segmentation via Local Calibration
Medical image segmentation under federated learning (FL) is a promising direction by allowing multiple clinical sites to collaboratively learn a global model without centralizing datasets. However, using a single model to adapt to various data distributions from different sites is extremely challenging. Personalized FL tackles this issue by only utilizing partial model parameters shared from global server, while keeping the rest to adapt to its own data distribution in the local training of each site. However, most existing methods concentrate on the partial parameter splitting, while do not consider the \textit{inter-site in-consistencies} during the local training, which in fact can facilitate the knowledge communication over sites to benefit the model learning for improving the local accuracy. In this paper, we propose a personalized federated framework with \textbf{L}ocal \textbf{C}alibration (LC-Fed), to leverage the inter-site in-consistencies in both \textit{feature- and prediction- levels} to boost the segmentation. Concretely, as each local site has its alternative attention on the various features, we first design the contrastive site embedding coupled with channel selection operation to calibrate the encoded features. Moreover, we propose to exploit the knowledge of prediction-level in-consistency to guide the personalized modeling on the ambiguous regions, e.g., anatomical boundaries. It is achieved by computing a disagreement-aware map to calibrate the prediction. Effectiveness of our method has been verified on three medical image segmentation tasks with different modalities, where our method consistently shows superior performance to the state-of-the-art personalized FL methods. Code is available at https://github.com/jcwang123/FedLC.
- 29 October 2021
- Published by Wiley in Advanced Materials
- Vol. 34 (4) , 2105120
A Tissue‐Like Soft All‐Hydrogel Battery
To develop wearable and implantable bioelectronics accommodating the dynamic and uneven biological tissues and reducing undesired immune responses, it is critical to adopt batteries with matched mechanical properties with tissues as power sources. However, the batteries available cannot reach the softness of tissues due to the high Young's moduli of components (e.g., metals, carbon materials, conductive polymers, or composite materials). The fabrication of tissue‐like soft batteries thus remains a challenge. Here, the first ultrasoft batteries totally based on hydrogels are reported. The ultrasoft batteries exhibit Young's moduli of 80 kPa, perfectly matching skin and organs (e.g., heart). The high specific capacities of 82 mAh g−1 in all‐hydrogel lithium‐ion batteries and 370 mAh g−1 in all‐hydrogel zinc‐ion batteries at a current density of 0.5 A g−1 are achieved. Both high stability and biocompatibility of the all‐hydrogel batteries have been demonstrated upon the applications of wearable and implantable. This work illuminates a pathway for designing power sources for wearable and implantable electronics with matched mechanical properties.
- 29 October 2021
- Published by Wiley in Advanced Materials
- Vol. 34 (4) , 2105120
A Tissue‐Like Soft All‐Hydrogel Battery
To develop wearable and implantable bioelectronics accommodating the dynamic and uneven biological tissues and reducing undesired immune responses, it is critical to adopt batteries with matched mechanical properties with tissues as power sources. However, the batteries available cannot reach the softness of tissues due to the high Young's moduli of components (e.g., metals, carbon materials, conductive polymers, or composite materials). The fabrication of tissue‐like soft batteries thus remains a challenge. Here, the first ultrasoft batteries totally based on hydrogels are reported. The ultrasoft batteries exhibit Young's moduli of 80 kPa, perfectly matching skin and organs (e.g., heart). The high specific capacities of 82 mAh g−1 in all‐hydrogel lithium‐ion batteries and 370 mAh g−1 in all‐hydrogel zinc‐ion batteries at a current density of 0.5 A g−1 are achieved. Both high stability and biocompatibility of the all‐hydrogel batteries have been demonstrated upon the applications of wearable and implantable. This work illuminates a pathway for designing power sources for wearable and implantable electronics with matched mechanical properties.
- 15 September 2021
- Published by Wiley in Advanced Functional Materials
- Vol. 31 (51) , 2107160
Designing Porous Antifouling Interfaces for High‐Power Implantable Biofuel Cell
Biofuel cells that can convert the chemical energy of biomass such as glucose into electricity are expected to continuously obtain energy from living organisms and solve bottlenecks of energy supply for implanted electronics. However, the use of biofuel cells is limited mainly by the sharp drop in performance after implanting in living organisms caused by biofouling and electrode surface inactivation. Herein, a simple and effective strategy to overcome these problems by designing a porous antifouling interface on biofuel cells, is demonstrated. It resists the biofouling from body fluid while sustaining reactant penetration, and also enhances immobilization of enzymes. As a result, the biofuel cell can maintain almost 100% performance after implanting in living organisms, and a maximal output power of 76.6 mW cm‐3 is achieved in vivo, which is ≈96 times of the highest performance reported to date. This strategy is universal and can be extended to the other electronic devices such as electrochemical sensors, which presents a new avenue for developing high‐performance implanted electronics.
- 15 September 2021
- Published by Wiley in Advanced Functional Materials
- Vol. 31 (51) , 2107160
Designing Porous Antifouling Interfaces for High‐Power Implantable Biofuel Cell
Biofuel cells that can convert the chemical energy of biomass such as glucose into electricity are expected to continuously obtain energy from living organisms and solve bottlenecks of energy supply for implanted electronics. However, the use of biofuel cells is limited mainly by the sharp drop in performance after implanting in living organisms caused by biofouling and electrode surface inactivation. Herein, a simple and effective strategy to overcome these problems by designing a porous antifouling interface on biofuel cells, is demonstrated. It resists the biofouling from body fluid while sustaining reactant penetration, and also enhances immobilization of enzymes. As a result, the biofuel cell can maintain almost 100% performance after implanting in living organisms, and a maximal output power of 76.6 mW cm‐3 is achieved in vivo, which is ≈96 times of the highest performance reported to date. This strategy is universal and can be extended to the other electronic devices such as electrochemical sensors, which presents a new avenue for developing high‐performance implanted electronics.