EHEr He

Er He

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Er He has a total of 54 co-authors. Here are the top co-authors by number of shared publications:

  • Ye Zhang

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    10 shared publications
  • Tingting Ye

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center (ChemBIC) Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    9 shared publications
  • Jiacheng Wang

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing China

    8 shared publications
  • Yiding Jiao

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing China

    8 shared publications
  • Fangyan Li

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Center Collaborative Innovation Center of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing China

    7 shared publications
  • Jiang Lu

    National Laboratory of Solid State Microstructures Jiangsu Key Laboratory of Artificial Functional Materials Chemistry and Biomedicine Innovation Centre Collaborative Innovation Centre of Advanced Microstructures College of Engineering and Applied Sciences Nanjing University Nanjing 210023 China

    7 shared publications

Latest Publications

  • A New Metalgel Current Collector for Simultaneous Rapid and Stable Zinc Electrochemistry

    by Fangyan Li, Er He, Yiding Jiao, Shuo Yang, Jiacheng Wang, Haidong Wang, Xinyu Liu, Xusong Li, Hanting Zhang, Yuanzhen Wang, et al.

    Achieving both high‐rate capability and long‐term cycling stability in zinc anode remains challenging due to the fundamental trade‐off. Fast kinetics require maximum interfacial area for charge transfer, while stability demands minimal zinc/electrolyte contact to suppress parasitic reactions and dendrite growth. However, in previous studies, zinc deposited at the electrode/electrolyte interface, leading to limited lifetimes (≤ 1200 h at a utilization ratio of ≥ 60%) and high overpotentials (≥ 480 mV at 50 mA·cm −2 ). Here, we design a new metalgel current collector to effectively resolve the above limitation. The metalgel comprises a biphasic gallium–indium–zinc continuum immobilized within a 3D polymer network, establishing both ion and electron conduction pathways that maximize the electrochemically active interface. The biphasic gallium–indium–zinc contains solid metallic zinc dispersed within the liquid gallium–indium–zinc alloy phase, enabling inward zinc deposition/stripping via a reversible dissolution–precipitation alloying process. This inward‐deposition/stripping minimizes zinc/electrolyte contact and suppresses parasitic reactions and dendrite formation, enabling zinc anodes to achieve over 4300 h of stable cycling at 80% zinc utilization ratio and maintain only 156.6 mV overpotential at an ultrahigh current density of 100 mA·cm −2 . By decoupling interfacial kinetics from interfacial instabilities, this work presents a new paradigm for high‐performance metal batteries.


  • Anion‐Confined Interface Enabling Uniform Stripping of Magnesium Anode

    by Shuo Yang, Hao‐Ran Xing, Yiding Jiao, Fangyan Li, Er He, Hanting Zhang, Chenyu Bai, Yiran Li, Yuanzhen Wang, Jie Song, et al.

    The non‐uniform stripping behavior of magnesium (Mg) anodes severely limits their utilization ratio and areal capacity, presenting a critical barrier to the practical application of Mg‐based batteries. Herein, an anion‐confined interface on the Mg anode is introduced that facilitates uniform stripping by regulating the migration of interfacial anions. This strategy enables Mg anodes to achieve a record‐high areal capacity of 17.24 mAh·cm −2 with a utilization ratio of 90%. Consequently, an unprecedented ampere‐hour‐scale rechargeable Mg‐ion pouch cell is demonstrated. Furthermore, modified Mg‐air batteries exhibit stable operation with a high average energy density of 2300 Wh·kg −1 , reducing performance deviation from 16.3% to 4.4%. These findings provide mechanistic insights into ion migration control at the Mg interface and offer a robust pathway toward high‐performance Mg‐based batteries.


  • Electrochemical Activation Inducing Rocksalt‐to‐Spinel Transformation for Prolonged Service Life of LiMn 2 O 4 Cathodes

    by Fangyan Li, Yiding Jiao, Shuo Yang, Wei Mao, Qiantu Tao, Chenyu Bai, Er He, Luhe Li, Tingting Ye, Yiran Li, et al.

    LiMn 2 O 4 spinel is emerging as a promising cathode material for lithium‐ion batteries, largely due to its open framework that facilitates Li + diffusion and excellent rate performance. However, the charge–discharge cycling of the LiMn 2 O 4 cathode leads to severe structural degradation and rapid capacity decay. Here, an electrochemical activation strategy is introduced, employing a facile galvano‐potentiostatic charging operation, to restore the lost capacity of LiMn 2 O 4 cathode without damaging the battery configuration. With an electrochemical activation strategy, the cycle life of the LiMn 2 O 4 cathode is extended from an initial 1500 to an impressive 14 000 cycles at a 5C rate with Li metal as the anode, while increasing the total discharge energy by ten times. Remarkably, the electrochemical activation enhances the diffusion kinetics of Li + , with the diffusion coefficient experiencing a 37.2% increase. Further investigation reveals that this improvement in capacity and diffusion kinetics results from a transformation of the redox‐inert LiMnO 2 rocksalt layer on the surface of degraded cathodes back into active spinel. This transformation is confirmed through electron microscopy and corroborated by density functional theory simulations. Moreover, the viability of this electrochemical activation strategy has been demonstrated in pouch cell configurations with Li metal as the anode, underscoring its potential for broader application.


  • A Temperature‐Sensing Hydrogel Coating on The Medical Catheter

    by Yiran Li, Dan Li, Jiacheng Wang, Tingting Ye, Qianming Li, Luhe Li, Rui Gao, Yuanzhen Wang, Junye Ren, Fangyan Li, et al.

    Medical surgical catheters are widely used in the medical field for drug delivery or postoperative drainage. However, infections associated with local temperature rise often occur at the catheter‐tissue interface, resulting in irreversible pathological damage, cognitive behavioral abnormalities, or even an increased risk of mortality if not monitored in time. Herein, an in situ temperature‐sensing hydrogel coating on the outer surface of medical surgical catheters for real‐time infection monitoring is developed. The hydrogel coating exhibits a record temperature coefficient of resistance of 2.90% °C−1 and maintains stable in vivo. Besides, the hydrogel layer forms a mechanically compatible catheter‐tissue interface and minimizes the risk of inflammatory responses due to its tissue‐like softness (Young's modulus of 4.24 kPa). By applying it in the early detection of infections in the brain of SD rats, the individual survival rate has increased to 90% with timely intervention.


  • A Mitochondrion‐Inspired Magnesium–Oxygen Biobattery with High Energy Density In Vivo

    by Er He, Junye Ren, Lie Wang, Fangyan Li, Luhe Li, Tingting Ye, Yiding Jiao, Dan Li, Jiacheng Wang, Yuanzhen Wang, et al.

    Implantable batteries are urgently needed as a power source to meet the demands of the next generation of biomedical electronic devices. However, existing implantable batteries suffer from unsatisfactory energy density, hindering the miniaturization of these devices. Here, a mitochondrion‐inspired magnesium–oxygen biobattery that achieves both high energy density and biocompatibility in vivo is reported. The resulting biobattery exhibits a recorded energy density of 2517 Wh L–1/1491 Wh kg–1 based on the total volume/mass of the device in vivo, which is ≈2.5 times higher than the current state‐of‐the‐art, and can adapt to different environments for stable discharges. The volume of the magnesium–oxygen biobattery can be as thin as 0.015 mm3 and can be scaled up to 400 times larger without reducing the energy density. Additionally, it shows a stable biobattery/tissue interface, significantly reducing foreign body reactions. This work presents an effective strategy for the development of high‐performance implantable batteries.


  • A Tissue‐Like Soft All‐Hydrogel Battery

    by Tingting Ye, Jiacheng Wang, Yiding Jiao, Luhe Li, Er He, Lie Wang, Yiran Li, Yanjing Yun, Dan Li, Jiang Lu, et al.

    To develop wearable and implantable bioelectronics accommodating the dynamic and uneven biological tissues and reducing undesired immune responses, it is critical to adopt batteries with matched mechanical properties with tissues as power sources. However, the batteries available cannot reach the softness of tissues due to the high Young's moduli of components (e.g., metals, carbon materials, conductive polymers, or composite materials). The fabrication of tissue‐like soft batteries thus remains a challenge. Here, the first ultrasoft batteries totally based on hydrogels are reported. The ultrasoft batteries exhibit Young's moduli of 80 kPa, perfectly matching skin and organs (e.g., heart). The high specific capacities of 82 mAh g−1 in all‐hydrogel lithium‐ion batteries and 370 mAh g−1 in all‐hydrogel zinc‐ion batteries at a current density of 0.5 A g−1 are achieved. Both high stability and biocompatibility of the all‐hydrogel batteries have been demonstrated upon the applications of wearable and implantable. This work illuminates a pathway for designing power sources for wearable and implantable electronics with matched mechanical properties.


  • Designing Porous Antifouling Interfaces for High‐Power Implantable Biofuel Cell

    by Lie Wang, Er He, Rui Gao, Xiaotong Wu, Anwei Zhou, Jiang Lu, Tiancheng Zhao, Jiaxin Li, Yanjing Yun, Luhe Li, et al.

    Biofuel cells that can convert the chemical energy of biomass such as glucose into electricity are expected to continuously obtain energy from living organisms and solve bottlenecks of energy supply for implanted electronics. However, the use of biofuel cells is limited mainly by the sharp drop in performance after implanting in living organisms caused by biofouling and electrode surface inactivation. Herein, a simple and effective strategy to overcome these problems by designing a porous antifouling interface on biofuel cells, is demonstrated. It resists the biofouling from body fluid while sustaining reactant penetration, and also enhances immobilization of enzymes. As a result, the biofuel cell can maintain almost 100% performance after implanting in living organisms, and a maximal output power of 76.6 mW cm‐3 is achieved in vivo, which is ≈96 times of the highest performance reported to date. This strategy is universal and can be extended to the other electronic devices such as electrochemical sensors, which presents a new avenue for developing high‐performance implanted electronics.


  • Engineering Polymer Glue towards 90% Zinc Utilization for 1000 Hours to Make High‐Performance Zn‐Ion Batteries

    by Yiding Jiao, Fangyan Li, Xin Jin, Qingsong Lei, Luhe Li, Lie Wang, Tingting Ye, Er He, Jiacheng Wang, Hao Chen, et al.

    Zinc (Zn) metal is considered the promising anode for “post‐lithium” energy storage due to its high volumetric capacity, low redox potential, abundant reserve, and low cost. However, extravagant Zn is required in present Zn batteries, featuring low Zn utilization rate and device‐scale energy/power densities far below theoretical values. The limited reversibility of Zn metal is attributed to the spontaneous parasitic reactions of Zn with aqueous electrolytes, that is, corrosion with water, passive by‐product formation, and dendrite growth. Here, a new ion‐selective polymer glue coated on Zn anode is designed, isolating the Zn anode from the electrolyte by blocking water diffusion while allowing rapid Zn2+ ion migration and facilitating uniform electrodeposition. Hence, a record‐high Zn utilization of 90% is realized for 1000 h at high current densities, in sharp contrast to much poorer cyclability (usually < 200 h) at lower Zn utilization (50–85%) reported to date. When matched with the vanadium‐based cathode, the resulting Zn‐ion battery exhibited an ultrahigh device‐scale energy density of 228 Wh kg−1, comparable to commercial lithium‐ion batteries.


  • High‐Energy‐Density Magnesium‐Air Battery Based on Dual‐Layer Gel Electrolyte

    by Luhe Li, Hao Chen, Er He, Lie Wang, Tingting Ye, Jiang Lu, Yiding Jiao, Jiacheng Wang, Rui Gao, Huisheng Peng, et al.

    Mg‐air batteries are explored as the next‐generation power systems for wearable and implantable electronics as they could work stably in neutral electrolytes and are also biocompatible. However, high corrosion rate and low utilization of Mg anode largely impair the performance of Mg‐air battery with low discharge voltage, poor specific capacity and low energy density. Here, to the best of our knowledge, we first report a dual‐layer gel electrolyte to simultaneously solve the above two problems by preventing the corrosion of Mg anode and the production of dense passive layer, respectively. The resulting Mg‐air batteries produced an average specific capacity of 2190 mAh g−1 based on the total Mg anode (99.3 % utilization rate of Mg anode) and energy density of 2282 Wh kg−1 based on the total anode and air electrode, both of which are the highest among the reported Mg‐air batteries. Besides, our Mg‐air batteries could be made into a fiber shape, and they were flexible to work stably under various deformations such as bending and twisting.


  • High‐Energy‐Density Magnesium‐Air Battery Based on Dual‐Layer Gel Electrolyte

    by Luhe Li, Hao Chen, Er He, Lie Wang, Tingting Ye, Jiang Lu, Yiding Jiao, Jiacheng Wang, Rui Gao, Huisheng Peng, et al.

    Mg‐air batteries are explored as the next‐generation power systems for wearable and implantable electronics as they could work stably in neutral electrolytes and are also biocompatible. However, high corrosion rate and low utilization of Mg anode largely impair the performance of Mg‐air battery with low discharge voltage, poor specific capacity and low energy density. Here, to the best of our knowledge, we first report a dual‐layer gel electrolyte to simultaneously solve the above two problems by preventing the corrosion of Mg anode and the production of dense passive layer, respectively. The resulting Mg‐air batteries produced an average specific capacity of 2190 mAh g−1 based on the total Mg anode (99.3 % utilization rate of Mg anode) and energy density of 2282 Wh kg−1 based on the total anode and air electrode, both of which are the highest among the reported Mg‐air batteries. Besides, our Mg‐air batteries could be made into a fiber shape, and they were flexible to work stably under various deformations such as bending and twisting.