TBThomas Bull

Thomas Bull

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas Bull has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The impact of surface dimensions on the accuracy of an intraoral scanner

    by Sneha Chotaliya, Saoirse O'TOole, Rupert S Austin, Thomas Bull, David Bartlett

  • Experimental Study of Arc Motion Near Splitter Plates in Low-Voltage Switching Devices

    by Dongkyu Shin, Thomas G. Bull, John W. McBride

    Switching performance of a low voltage switching device (LVSD) is determined by limiting current and stopping re-ignition. This is strongly influenced by how the arc moves inside the LVSD quenching chamber during the switching process. Improved switching performance is achieved when the arc quickly enters and stays inside the splitter plates of the LVSD, with the arc attached to the surface of the plates. This paper studies arc motion around splitter plates in LVSDs and the correlation with arc voltage. Arc motion is investigated using a high-speed optical arc imaging system (AIS). It is observed that the arc fluctuates as it enters the splitter plates, with periods inside the plates followed by sudden re-strikes of the arc roots outside the plates. The AIS system allows the measurement of arc displacement and a correlation with the arc voltage. The results show two phases, with a narrow correlation while the arc in the chamber out of the splitter plates and a distributed correlation while in the splitter plates. Further a new performance parameter the splitter time (ST) ratio is defined. The influence of the ST ratio on the chamber vent design is investigated. It is found that with wider and well distributed vent apertures the ST ratio is higher than with a closed vent, and arc motion on entry to the plates is improved.


  • Open Access

    Surface form analysis on complex freeform organic structures – measuring erosive wear on human teeth in vitro

    by P Mylonas, R Moazzez, A Joiner, D Bartlett, T Bull, J McBride

    Natural human enamel (NHE) is a complex freeform surface which has presented significant difficulties in measuring surface form change using non-contacting laser profilometry (NCLP). Measuring surface form change on NHE is a metrology proxy for measuring dental tooth structure loss, and characterising this using non-ISO parameters (volume, surface area, and normalised lesion depth) has been seldom studied due surface complexity and undetermined measurement errors. This study determines NCLP measurement errors (instrument repeatability and method reproducibility) for non-ISO parameters, characterises change in surface form on NHE following a dietary pH-cycling model. NHE (n = 1) was scanned consecutively twenty-times using NCLP with/without sample replacement producing consecutive surface profile data. Residual data was created after subtracting consecutive filtered profile data (80 μm, Gaussian filter), and mean (SD) volume, surface area, and normalised lesion depth was determined within a 1.5 mm circular region of interest (ROI). Volume error (expressed as height variation across ROI surface area) was 0.022 μm (instrument repeatability) and 0.149 μm (method reproducibility), whilst surface area error (expressed as percentage change of the surface area deviation across the entire surface area) was 0.034% (repeatability error) and 0.081% (reproducibility error). Sixty-four natural enamel surfaces taped with polyvinyl-chloride tape leaving 1.5 mm exposed ROI underwent dietary erosion cycling (three 5-min cycles, 0.3% citric acid w/v, pH 3.2) generating artificial erosion lesions. Samples were scanned with NCLP before/after each erosion cycle, scans filtered for microtexture, and after-erosion scans were subtracted from before-erosion scans. NCLP results show mean (SD) volume, surface area, normalised depth, and 3D step-height of the eroded area increased significantly after each erosion cycle, with no significant difference in calcium and phosphate release after each cycle. We demonstrate a robust and valid dental model with analysis workflow to measure surface form change in NHE using NCLP, improving understanding of measuring surface form change in complex freeform surfaces.


  • The measurement threshold and limitations of an intra-oral scanner on polished human enamel

    by Polyvios Charalambous, Saoirse O’toole, Thomas Bull, David Bartlett, Rupert Austin


  • Experimental Study of Relationship Between Arc Light Intensity and Temperature in Low-Voltage Switching Devices

    by Dongkyu Shin, Thomas G. Bull, John W. McBride

    Arc motion in a quenching chamber has a significant influence on switching performance in a low voltage switching device (LVSD). A high-speed optical arc imaging system (AIS) has been used to investigate the influence of the design parameters of a quenching chamber on arc motion. Arc light intensity is transmitted to the photodiodes of the AIS through optical fibres during the switching process. The AIS and associated software enable the detailed arc motion to be tracked inside the chamber at an image sampling rate of 1 MHz. Since higher arc temperature leads to greater radiation, it is assumed that the arc light intensity measured by the AIS is related to the arc temperature. However, there has been little empirical study of the correlation between the arc temperature and light intensity measured by the AIS. In this paper, the relationship between the arc temperature and light intensity is investigated by measuring arc spectra and arc images. Arc spectra are captured by a spectrometer when the arc is ignited by copper wire in a narrow enclosed chamber and they are used to calculate the arc temperature by the Boltzmann plot method. At the same time, the AIS records the arc images from points adjacent to the fibre of the arc spectrometer. It is found that the arc light intensity measured by the AIS is directly related to the arc temperature; the correlation between the fourth power of temperature and the light intensity is an approximately linear trend.


  • Optical metrology for the morphological characterization of surfaces: limitations, innovations, registration, and new directions

    by John W. McBride, Kevin J. Cross, Thomas Bull

    An overview is provided of the non-contact measurement of surface morphology, focusing on form and roughness. Existing methods considered include con-focal scanning methods for the evaluation of large-scale surfaces where comparisons are drawn with direct areal measurements where data stitching is required to provide coverage of large scale surfaces. The applications of large-scale surfaces presented include, free form dental metrology, paleontology and early cylindrical mechanical sound recordings. Data registration of free form surfaces is presented to determine low scale wear of dental surfaces. For the new directions, consideration is given to the application of precision X-ray computer tomography, to determine free form surfaces and applied to the dental surfaces. The results show that the con-focal method remains the best solution for complex free form surfaces and that the XCT systems while offering some advantages require further research for full application.

  • The In-situ Wear of a Hot and Cold Switched Au on Au Coated MWCNT Electrical Contact for a MEMS Switch Application

    by J. W. McBride, T. G. Bull

    The electrical contacts in metal-metal MEMS switches are normally made from thin (> $1~\mu \text{m}$) metallic film, e.g., (Au). The low contact force in a MEMS device results in a small area for conduction; to increase the area, a composite contact material has been developed. Sputter coated Au, applied to vertically-aligned multi-walled carbon nanotubes, (Au-MWCNT composite), has been shown to increase contact area and extend switching lifetime by orders of magnitude. In this study the Au-MWCNT composite contact is paired with a Au coated hemisphere contact under a contact force of$150~\mu \text{N}$, in an In-situ Contact Evolution (ICE) apparatus, to evaluate the durability of the contacts for two DC switching conditions; cold switching, at 4 V, $4~\mu \text{A}$, ($16\mu \text{W}$) and hot switching at 4 V, 50 mA (200mW). Under cold switching the contacts are shown to maintain a low stable resistance for 4 Billion cycles. The result leads to a re-evaluation of an established fine transfer model, used to predict switching life times.


  • The influence of Circuit Parameters on Molten Bridge Surface Degradation in a Au/MWCNT MEMS Switch Contact

    by Thomas. G. Bull, John W. McBride, Liudi Jiang

    The influence of circuit parameters on an Ohmic (metal-metal contact) MEMS (microelectromechanical system) switch contact pair are investigated under hot-switching (carrying current) circuit conditions below the arcing-threshold. A novel MEMS relay testing platform is used to investigate microscale contact surface change between individual switching events. The contact materials are a composite contact material of vertically-aligned carbon-nanotubes with a metallic (Au) layer, paired with an Au-coated ball contact. The evolution of the contact surface is evaluated along with the energy associated with the molten-metal bridge (MMB) phenomena. Circuit voltage is varied between 4 and 8 V DC and current between 20 and 50 mA to determine their influence on surface degradation. Two modes of voltage transient are observed. The first has been linked to the formation of a MMB and the second to a delamination event (DE) where the contacts separate with no MMB apparent. Results are presented on the relative likelihood of the DE or the MMB events occurring. After 100k cycles at switching conditions of 4V, 20 mA the contact surface demonstrates negligible wear. Increasing the current (4 V, 50 mA) or the voltage (8 V, 20 mA) both increase the average energy associated with opening and the contact wear. The increase in MMB energy and wear with supply voltage is unexpected and is discussed.


  • Experimental study on the influence of vent aperture size and distribution on arc motion and interruption in low-voltage switching devices

    by Dongkyu Shin, Igor O. Golosnoy, Thomas G. Bull, John W. McBride

    Enhanced switching performance during the interruption process is achieved when the arc quickly enters and stays within the splitter plate region with the arc itself remaining attached to the surface of the plates. It is well known that the vent design in low-voltage switching devices (LVSDs) has a significant influence on arc motion during an interruption event: however, there has been limited experimental studies correlating arc motion in the whole quenching chamber, including splitter plates region, to the size and distribution of the vent apertures, which are important for plasma flow in LVSDs. This paper uses high speed optical arc imaging to investigate arc motion in a LVSD as the vent aperture conditions are varied. It is shown that the arc moves further and more quickly if there is the larger vent size in the quenching chamber. In addition, the well distributed vent contributes to an increase in arc motion velocity and reduction in total arc duration.