Alireza Tabrizikahou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alireza Tabrizikahou has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Mieczysław Kuczma
Institute of Building Engineering, Poznan University of Technology, Piotrowo 5, 60-965 Poznan, Poland
8 shared publications - Jan Białasik
Institute of Building Engineering, Poznan University of Technology, Piotrowo 5, 60-965 Poznan, Poland
4 shared publications - Moslem Shahverdi
Empa, Swiss Fed Labs Mat Sci & Technol, Uberlandstr 129, CH-8600 Dubendorf, Switzerland
4 shared publications - Magdalena Łasecka-Plura
Institute of Structural Analysis, Poznan University of Technology, Piotrowo 5, 60-965 Poznań, Poland
3 shared publications - Ahad Javanmardi
College of Civil Engineering, Key Lab of Fujian Province, University Town, Fuzhou University, Fuzhou, China
2 shared publications - Dominika Samulczyk
Institute of Building Engineering, Poznan University of Technology, Piotrowo 5, 60-965 Poznan, Poland
2 shared publications
Latest Publications
- Open Access
Direct Tensile Behavior of Thermally Activated Concrete Reinforced with Short Iron-Based Shape Memory Alloy (Fe-SMA) Fibers: Experimental and Numerical Investigation
Short iron-based shape memory alloy (Fe-SMA) fibers can act as active internal reinforcement after thermal activation. This study examined the direct tensile behavior of concrete containing 2.0% by volume of straight Fe-SMA fibers, geometrically identical steel fibers, or no fibers. ASTM C307 briquettes were tested under ambient conditions and after a 150 min hold at a chamber temperature of 160 °C, followed by cooling. Plain-concrete flexural and compressive tests characterized matrix degradation. Mean tensile strengths were 7.96 and 7.18 MPa for the unheated steel-fiber and Fe-SMA groups, respectively. After heating, these values were 5.89 and 9.41 MPa. The Fe-SMA increase was 31.1%, corresponding to a mean difference of 2.23 MPa with a 95% confidence interval of 1.66–2.80 MPa. A three-dimensional ABAQUS/CAE model with randomly distributed, fully bonded fibers reproduced the main response features using a recovery-stress target adopted from prior same-batch characterization. Separate numerical sweeps predicted higher strength with increasing fiber content and decreasing diameter within the investigated ranges. These results support the feasibility of thermally activated short Fe-SMA reinforcement. The numerical recommendations remain conditional on the idealized interface, adopted activation model, and investigated parameter ranges. Direct core-temperature monitoring and microscopic interface characterization remain necessary for further validation.
Open AccessDirect Tensile Behavior of Thermally Activated Concrete Reinforced with Short Iron-Based Shape Memory Alloy (Fe-SMA) Fibers: Experimental and Numerical Investigation
Short iron-based shape memory alloy (Fe-SMA) fibers can act as active internal reinforcement after thermal activation. This study examined the direct tensile behavior of concrete containing 2.0% by volume of straight Fe-SMA fibers, geometrically identical steel fibers, or no fibers. ASTM C307 briquettes were tested under ambient conditions and after a 150 min hold at a chamber temperature of 160 °C, followed by cooling. Plain-concrete flexural and compressive tests characterized matrix degradation. Mean tensile strengths were 7.96 and 7.18 MPa for the unheated steel-fiber and Fe-SMA groups, respectively. After heating, these values were 5.89 and 9.41 MPa. The Fe-SMA increase was 31.1%, corresponding to a mean difference of 2.23 MPa with a 95% confidence interval of 1.66–2.80 MPa. A three-dimensional ABAQUS/CAE model with randomly distributed, fully bonded fibers reproduced the main response features using a recovery-stress target adopted from prior same-batch characterization. Separate numerical sweeps predicted higher strength with increasing fiber content and decreasing diameter within the investigated ranges. These results support the feasibility of thermally activated short Fe-SMA reinforcement. The numerical recommendations remain conditional on the idealized interface, adopted activation model, and investigated parameter ranges. Direct core-temperature monitoring and microscopic interface characterization remain necessary for further validation.
- Open Access
- 13 October 2026
- Published by MDPI AG in Preprints.org
Direct Tensile Behavior of Thermally Activated Concrete Reinforced with Short Iron-Based Shape Memory Alloy (Fe-SMA) Fibers: Experimental and Numerical Investigation
Short iron-based shape memory alloy (Fe-SMA) fibers can act as active internal reinforcement after thermal activation. This study examined the direct tensile behavior of concrete containing 2.0% by volume of straight Fe-SMA fibers, geometrically identical steel fibers, or no fibers. ASTM C307 briquettes were tested under ambient conditions and after a 150 min hold at a chamber temperature of 160 ◦C, followed by cooling. Plain-concrete flexural and compressive tests characterized matrix degradation. Mean tensile strengths were 7.96 and 7.18 MPa for the unheated steel-fiber and Fe-SMA groups, respectively. After heating, these values were 5.89 and 9.41 MPa. The Fe-SMA increase was 31.1%, corresponding to a mean difference of 2.23 MPa with a 95% confidence interval of 1.66–2.80 MPa. A three-dimensional ABAQUS/CAE model with randomly distributed, fully bonded fibers reproduced the main response features using a recovery-stress target adopted from prior same-batch characterization. Separate numerical sweeps predicted higher strength with increasing fiber content and decreasing diameter within the investigated ranges. These results support the feasibility of thermally activated short Fe-SMA reinforcement. The numerical recommendations remain conditional on the idealized interface, adopted activation model, and investigated parameter ranges. Direct core-temperature monitoring and microscopic interface characterization remain necessary for further validation.
- 13 October 2026
- Published by MDPI AG in Preprints.org
Open AccessDirect Tensile Behavior of Thermally Activated Concrete Reinforced with Short Iron-Based Shape Memory Alloy (Fe-SMA) Fibers: Experimental and Numerical Investigation
Short iron-based shape memory alloy (Fe-SMA) fibers can act as active internal reinforcement after thermal activation. This study examined the direct tensile behavior of concrete containing 2.0% by volume of straight Fe-SMA fibers, geometrically identical steel fibers, or no fibers. ASTM C307 briquettes were tested under ambient conditions and after a 150 min hold at a chamber temperature of 160 ◦C, followed by cooling. Plain-concrete flexural and compressive tests characterized matrix degradation. Mean tensile strengths were 7.96 and 7.18 MPa for the unheated steel-fiber and Fe-SMA groups, respectively. After heating, these values were 5.89 and 9.41 MPa. The Fe-SMA increase was 31.1%, corresponding to a mean difference of 2.23 MPa with a 95% confidence interval of 1.66–2.80 MPa. A three-dimensional ABAQUS/CAE model with randomly distributed, fully bonded fibers reproduced the main response features using a recovery-stress target adopted from prior same-batch characterization. Separate numerical sweeps predicted higher strength with increasing fiber content and decreasing diameter within the investigated ranges. These results support the feasibility of thermally activated short Fe-SMA reinforcement. The numerical recommendations remain conditional on the idealized interface, adopted activation model, and investigated parameter ranges. Direct core-temperature monitoring and microscopic interface characterization remain necessary for further validation.
- Open Access
Electrical Resistance Activation of Embedded Fe-SMA Rebars in Pre-Cracked UHPFRC Beams: Internal Temperature Evolution and Calibrated Electro-Thermal Simulation
Iron-based shape memory alloy (Fe–SMA) rebars can generate internal prestress in cement-based members after restrained thermal activation; however, the temperature actually reached by embedded rebars in cracked UHPFRC is difficult to infer from exposed bar segments. This study investigates electrical resistance activation of 4% prestrained Fe–SMA rebars embedded in pre-cracked UHPFRC beams and clarifies the activation-control problem by combining thermocouple measurements with a calibrated two-dimensional electro-thermal simulator. Twelve beams (150 × 150 × 600 mm) containing either Dramix 3D or Dramix 4D hooked steel fibers were first loaded in three-point bending to a mid-span displacement of 4 mm. The 4D series reached a 9.47% higher average pre-cracking load, confirming that fiber geometry modified the cracked state before heating. During activation, the exposed rebar segment reached 200 °C after approximately 77 s, whereas the embedded working segment reached the same target only after approximately 213 s; at that moment, the exposed segment was already close to 350 °C. The calibrated simulator reproduced the target activation time with an error of approximately 3 s and visualized the localized heat transfer from Fe–SMA to UHPFRC. The results demonstrate that activation control based only on exposed-bar temperature may cause under-activation of the embedded reinforcement, and that direct internal temperature monitoring is required for reliable Fe–SMA activation in cracked UHPFRC members.
Open AccessElectrical Resistance Activation of Embedded Fe-SMA Rebars in Pre-Cracked UHPFRC Beams: Internal Temperature Evolution and Calibrated Electro-Thermal Simulation
Iron-based shape memory alloy (Fe–SMA) rebars can generate internal prestress in cement-based members after restrained thermal activation; however, the temperature actually reached by embedded rebars in cracked UHPFRC is difficult to infer from exposed bar segments. This study investigates electrical resistance activation of 4% prestrained Fe–SMA rebars embedded in pre-cracked UHPFRC beams and clarifies the activation-control problem by combining thermocouple measurements with a calibrated two-dimensional electro-thermal simulator. Twelve beams (150 × 150 × 600 mm) containing either Dramix 3D or Dramix 4D hooked steel fibers were first loaded in three-point bending to a mid-span displacement of 4 mm. The 4D series reached a 9.47% higher average pre-cracking load, confirming that fiber geometry modified the cracked state before heating. During activation, the exposed rebar segment reached 200 °C after approximately 77 s, whereas the embedded working segment reached the same target only after approximately 213 s; at that moment, the exposed segment was already close to 350 °C. The calibrated simulator reproduced the target activation time with an error of approximately 3 s and visualized the localized heat transfer from Fe–SMA to UHPFRC. The results demonstrate that activation control based only on exposed-bar temperature may cause under-activation of the embedded reinforcement, and that direct internal temperature monitoring is required for reliable Fe–SMA activation in cracked UHPFRC members.
- Open Access
Synergistic Effects of Fiber Inclination, Geometry, and Thermal Treatment on Fe-SMA Fiber Pull-Out Resistance in High-Performance Concrete
Iron-based shape memory alloy (Fe-SMA) fibers can enhance cementitious composites through both crack bridging and thermally activated recovery stresses. Since fiber pull-out governs load transfer at the micro scale, understanding the combined effects of fiber geometry, inclination, and thermal treatment is essential. This study experimentally investigated the pull-out behavior of hooked-end Fe-SMA fibers embedded in high-performance concrete (HPC). A total of 54 ASTM C307-type briquette specimens were tested using single-hook (3D) and double-hook (4D) fibers at inclination angles of 60°, 75°, and 90° under ambient, 100 °C, and 200 °C conditions. Additional flexural, compressive, and direct tensile tests were conducted on plain HPC exposed to the same thermal regime. At ambient temperature, 4D fibers showed 50–70% higher peak pull-out forces than 3D fibers. Heating to 100 °C further increased pull-out resistance by about 6–17%, and the 4D-60-100 configuration achieved the highest performance. In contrast, exposure to 200 °C reduced pull-out resistance by about 5–12% below ambient values. Overall, a 60° inclination generally provided a better response, while 90° produced the lowest. The results confirm that moderate thermal activation combined with double-hook geometry is the most effective strategy for maximizing Fe-SMA fiber–matrix load transfer in HPC.
Open AccessSynergistic Effects of Fiber Inclination, Geometry, and Thermal Treatment on Fe-SMA Fiber Pull-Out Resistance in High-Performance Concrete
Iron-based shape memory alloy (Fe-SMA) fibers can enhance cementitious composites through both crack bridging and thermally activated recovery stresses. Since fiber pull-out governs load transfer at the micro scale, understanding the combined effects of fiber geometry, inclination, and thermal treatment is essential. This study experimentally investigated the pull-out behavior of hooked-end Fe-SMA fibers embedded in high-performance concrete (HPC). A total of 54 ASTM C307-type briquette specimens were tested using single-hook (3D) and double-hook (4D) fibers at inclination angles of 60°, 75°, and 90° under ambient, 100 °C, and 200 °C conditions. Additional flexural, compressive, and direct tensile tests were conducted on plain HPC exposed to the same thermal regime. At ambient temperature, 4D fibers showed 50–70% higher peak pull-out forces than 3D fibers. Heating to 100 °C further increased pull-out resistance by about 6–17%, and the 4D-60-100 configuration achieved the highest performance. In contrast, exposure to 200 °C reduced pull-out resistance by about 5–12% below ambient values. Overall, a 60° inclination generally provided a better response, while 90° produced the lowest. The results confirm that moderate thermal activation combined with double-hook geometry is the most effective strategy for maximizing Fe-SMA fiber–matrix load transfer in HPC.
- Open Access
- 19 March 2026
- Published by MDPI AG in Preprints.org
Synergistic Effects of Fiber Inclination, Geometry, and Thermal Treatment on Fe-SMA Fiber Pullout Resistance in High-Performance Concrete
Iron-based shape memory alloy (Fe-SMA) fibers can enhance cementitious composites through both crack-bridging and thermally activated recovery stresses. Since fiber pull-out governs load transfer at the microscale, understanding the combined effects of fiber geometry, inclination, and thermal treatment is essential. This study experimentally investigated the pull-out behavior of hooked-end Fe-SMA fibers embedded in high-performance concrete (HPC). A total of 54 ASTM C307-type briquette specimens were tested using single-hook (3D) and double-hook (4D) fibers at inclination angles of 60∘, 75∘, and 90∘ under ambient, 100 ∘C, and 200 ∘C conditions. Additional flexural, compressive, and direct tensile tests were conducted on plain HPC exposed to the same thermal regime. At ambient temperature, 4D fibers showed 50–70% higher peak pull-out forces than 3D fibers. Heating to 100 ∘C further increased pull-out resistance by about 6–17%, and the 4D-60-100 configuration achieved the highest performance. In contrast, exposure to 200 ∘C reduced pull-out resistance by about 5–12% below ambient values. Overall, a 60∘ inclination generally provided the best response, while 90∘ produced the lowest. The results confirm that moderate thermal activation combined with double-hook geometry is the most effective strategy for maximizing Fe-SMA fiber–matrix load transfer in HPC.
- 19 March 2026
- Published by MDPI AG in Preprints.org
Open AccessSynergistic Effects of Fiber Inclination, Geometry, and Thermal Treatment on Fe-SMA Fiber Pullout Resistance in High-Performance Concrete
Iron-based shape memory alloy (Fe-SMA) fibers can enhance cementitious composites through both crack-bridging and thermally activated recovery stresses. Since fiber pull-out governs load transfer at the microscale, understanding the combined effects of fiber geometry, inclination, and thermal treatment is essential. This study experimentally investigated the pull-out behavior of hooked-end Fe-SMA fibers embedded in high-performance concrete (HPC). A total of 54 ASTM C307-type briquette specimens were tested using single-hook (3D) and double-hook (4D) fibers at inclination angles of 60∘, 75∘, and 90∘ under ambient, 100 ∘C, and 200 ∘C conditions. Additional flexural, compressive, and direct tensile tests were conducted on plain HPC exposed to the same thermal regime. At ambient temperature, 4D fibers showed 50–70% higher peak pull-out forces than 3D fibers. Heating to 100 ∘C further increased pull-out resistance by about 6–17%, and the 4D-60-100 configuration achieved the highest performance. In contrast, exposure to 200 ∘C reduced pull-out resistance by about 5–12% below ambient values. Overall, a 60∘ inclination generally provided the best response, while 90∘ produced the lowest. The results confirm that moderate thermal activation combined with double-hook geometry is the most effective strategy for maximizing Fe-SMA fiber–matrix load transfer in HPC.
- 15 February 2025
- Published by Elsevier in Construction and Building Materials
- Vol. 467
Prestressing of concrete using iron-based shape memory alloy (Fe-SMA) short fibers: Experimental and numerical analysis
- 15 February 2025
- Published by Elsevier in Construction and Building Materials
- Vol. 467
Prestressing of concrete using iron-based shape memory alloy (Fe-SMA) short fibers: Experimental and numerical analysis
- Open Access
- 11 January 2025
- Published by Elsevier in Engineering Structures
- Vol. 327
Multiphysical simulation of iron-based shape memory alloy (Fe-SMA) activation embedded in concrete structures
- 11 January 2025
- Published by Elsevier in Engineering Structures
- Vol. 327
Open AccessMultiphysical simulation of iron-based shape memory alloy (Fe-SMA) activation embedded in concrete structures