Zhan Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhan Gao has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Jianfeng Zhao
College of Mechanical and Electrical Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publications - Yaohua Li
School of Automotive, Chang’an University, Xi’an, China
2 shared publications - Alberto M. Cuitino
Department of Mechanical and Aerospace Engineering, Rutgers University, Piscataway, NJ 08854, USA
1 shared publication - Bo Zhang
South China University of Technology
1 shared publication - Cheng Jin
School of Electrical Engineering, Southeast University, Nanjing, China
1 shared publication - Dong Yang
School of Civil Engineering, Chongqing University 1 , No. 83 Shabeijie, Shapingba, Chongqing 400045
1 shared publication
Latest Publications
- 29 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (7) , 8517-8538
Hybrid Improved Carrier-Based PWM Strategy for Three-Level Neutral-Point-Clamped Inverter With Wide Frequency Range
The three-level neutral-point-clamped inverter used in the variable frequency system has the characteristics of a wide frequency range, and the PWM strategy needs to be designed for the low-frequency region with low modulation index and the high-frequency region with low carrier ratio, respectively. The traditional carrier-based PWM (CBPWM) is simple to implement, but in the low-frequency region, CBPWM will cause narrow pulse and voltage distortion; while in the high-frequency region, CBPWM can only achieve the synchronized modulation with half-wave symmetrical (HWS) and three-phase symmetrical (TPS) waveforms when the carrier ratio is an odd integer multiple of three, and it cannot realize the square-wave modulation. To solve the defects of CBPWM, this paper proposes improved CBPWM (ICBPWM) I, which can avoid narrow pulse and generate line voltage accurately at any low modulation index, ICBPWM II, which can ensure the voltage to meet TPS and HWS when the carrier ratio is an arbitrary integer multiple of three, and ICBPWM III, which can achieve square-wave modulation, separately. On this basis, by using ICBPWM I, ICBPWM II, and ICBPWM III in combination, a hybrid ICBPWM strategy with wide frequency range is further proposed. Finally, the proposed strategy is verified by simulation and experiment.
- 29 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (7) , 8517-8538
Hybrid Improved Carrier-Based PWM Strategy for Three-Level Neutral-Point-Clamped Inverter With Wide Frequency Range
The three-level neutral-point-clamped inverter used in the variable frequency system has the characteristics of a wide frequency range, and the PWM strategy needs to be designed for the low-frequency region with low modulation index and the high-frequency region with low carrier ratio, respectively. The traditional carrier-based PWM (CBPWM) is simple to implement, but in the low-frequency region, CBPWM will cause narrow pulse and voltage distortion; while in the high-frequency region, CBPWM can only achieve the synchronized modulation with half-wave symmetrical (HWS) and three-phase symmetrical (TPS) waveforms when the carrier ratio is an odd integer multiple of three, and it cannot realize the square-wave modulation. To solve the defects of CBPWM, this paper proposes improved CBPWM (ICBPWM) I, which can avoid narrow pulse and generate line voltage accurately at any low modulation index, ICBPWM II, which can ensure the voltage to meet TPS and HWS when the carrier ratio is an arbitrary integer multiple of three, and ICBPWM III, which can achieve square-wave modulation, separately. On this basis, by using ICBPWM I, ICBPWM II, and ICBPWM III in combination, a hybrid ICBPWM strategy with wide frequency range is further proposed. Finally, the proposed strategy is verified by simulation and experiment.
- 1 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis and Modeling of Multi-mode Operation for Series-parallel CLLC Resonant Converter
The direct current converters will be the key device for DC power distribution to achieve flexible control and active management of voltage and power between the medium-voltage direct current (MVDC) distribution grid and the low voltage direct current micro-grid. This paper proposes a new control strategy for the dual-active-bridge (DAB) converters with CLLC resonant tank. Compared to traditional control strategies, three modes of operation are in the new strategy to achieve bidirectional transmission of power and voltage control. Each mode of operation provides an accurate modeling analysis process to obtain a small-signal model. Series voltage balance and parallel power balance of the resonators are theoretically equivalent. In addition, distributed, modular, and plug & play design strategies also can be easily applied for the converter. The simulation results verify the effectiveness of the analysis and modeling.
- 1 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Analysis and Modeling of Multi-mode Operation for Series-parallel CLLC Resonant Converter
The direct current converters will be the key device for DC power distribution to achieve flexible control and active management of voltage and power between the medium-voltage direct current (MVDC) distribution grid and the low voltage direct current micro-grid. This paper proposes a new control strategy for the dual-active-bridge (DAB) converters with CLLC resonant tank. Compared to traditional control strategies, three modes of operation are in the new strategy to achieve bidirectional transmission of power and voltage control. Each mode of operation provides an accurate modeling analysis process to obtain a small-signal model. Series voltage balance and parallel power balance of the resonators are theoretically equivalent. In addition, distributed, modular, and plug & play design strategies also can be easily applied for the converter. The simulation results verify the effectiveness of the analysis and modeling.
- 1 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Line Parameter Estimation of Distribution Network after Grounding Fault
With the high impedance single-phase ground fault occurs in a distribution network, the line parameters will change substantially. Typically, the neutral resonance grounding is used to compensate the fault current. Better results can be achieved with active compensation, but precise line parameters need to be known. In this paper, an existing method of estimating distribution line parameters using only RMS voltage and power measurements is employed to estimate distribution line parameters after high impedance single-phase ground fault. The power flow equation without voltage phase angle, the compensation model of active compensation device and the measurement error compensation model are established. Simulation results obtain the required line parameters while reducing measurement error and computational complexity. It is conducive to the subsequent state analysis of distribution lines.
- 1 February 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Line Parameter Estimation of Distribution Network after Grounding Fault
With the high impedance single-phase ground fault occurs in a distribution network, the line parameters will change substantially. Typically, the neutral resonance grounding is used to compensate the fault current. Better results can be achieved with active compensation, but precise line parameters need to be known. In this paper, an existing method of estimating distribution line parameters using only RMS voltage and power measurements is employed to estimate distribution line parameters after high impedance single-phase ground fault. The power flow equation without voltage phase angle, the compensation model of active compensation device and the measurement error compensation model are established. Simulation results obtain the required line parameters while reducing measurement error and computational complexity. It is conducive to the subsequent state analysis of distribution lines.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Analysis and Design of Fault-Tolerant Control of ANPC Inverter for Traction System
In this paper, a fault-tolerant control strategy of ANPC for traction-system is proposed. When ANPC inverters are used in the traction system, the device failure will lead to unpredictable failures of the motor. The fault-tolerant control strategy can effectively improve the reliability and stability of the traction system. This paper presents a new fault-tolerant control method for ANPC inverter. This method can effectively maintain the stability of the system when a transient fault or permanent fault occurs. Simulation and experimental results have proved the validity of the methods.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Analysis and Design of Fault-Tolerant Control of ANPC Inverter for Traction System
In this paper, a fault-tolerant control strategy of ANPC for traction-system is proposed. When ANPC inverters are used in the traction system, the device failure will lead to unpredictable failures of the motor. The fault-tolerant control strategy can effectively improve the reliability and stability of the traction system. This paper presents a new fault-tolerant control method for ANPC inverter. This method can effectively maintain the stability of the system when a transient fault or permanent fault occurs. Simulation and experimental results have proved the validity of the methods.
- 1 January 2005
- Published by ASME International in Journal of Engineering Materials and Technology
- Vol. 127 (1) , 40-45
Fatigue of As-Fabricated Open Cell Aluminum Foams
This paper presents the results of the combined experimental investigation and digital image correlation (DIC) analysis of the fatigue failure of open cell aluminum foams. Compression–compression cyclic loads were applied to foam specimens under the as-fabricated condition. Following characterization of the S-N curve behavior, the macroscale deformation of the tested foam under fatigue was recorded using an in-situ digital camera. The deformation sequence was then analyzed using DIC technique. It was found that foams failed with an abrupt strain jump when shear bands were formed, and serious deformation up to more than 30% was developed in the center of the shear band. The ex-situ scanning electron microscopy analysis indicated that the abrupt strain jump was due to the microscale damage accumulation in struts where surface cracks were formed and propagated.
- 1 January 2005
- Published by ASME International in Journal of Engineering Materials and Technology
- Vol. 127 (1) , 40-45
Fatigue of As-Fabricated Open Cell Aluminum Foams
This paper presents the results of the combined experimental investigation and digital image correlation (DIC) analysis of the fatigue failure of open cell aluminum foams. Compression–compression cyclic loads were applied to foam specimens under the as-fabricated condition. Following characterization of the S-N curve behavior, the macroscale deformation of the tested foam under fatigue was recorded using an in-situ digital camera. The deformation sequence was then analyzed using DIC technique. It was found that foams failed with an abrupt strain jump when shear bands were formed, and serious deformation up to more than 30% was developed in the center of the shear band. The ex-situ scanning electron microscopy analysis indicated that the abrupt strain jump was due to the microscale damage accumulation in struts where surface cracks were formed and propagated.