SRStefan Alexander Rudhart

Stefan Alexander Rudhart

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stefan Alexander Rudhart has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Stephan Hoch

    Department of Otolaryngology, Head and Neck Surgery, University Hospital Marburg, Philipps-Universität Marburg, Marburg, Germany.

    5 shared publications
  • Boris A. Stuck

    Department of Otolaryngology, Head and Neck Surgery, University Hospital Marburg, Philipps-University of Marburg, Marburg, Germany

    2 shared publications
  • Francesca Gehrt

    Affiliation Department of Otolaryngology, Head and Neck Surgery, University Hospital Marburg, Philipps-University, Marburg, Hessen, Germany

    2 shared publications
  • Frank Günther

    Affiliation Department of Medical Microbiology and Hygiene, University Hospital Marburg, Philipps-University, Marburg, Hessen, Germany

    2 shared publications
  • A. Nastev

    1 shared publication
  • Alexander Philippe Maas

    Klinik und Poliklinik für Hals-Nasen-Ohren-Heilkunde, Universitätsklinikum Bonn, Bonn, Deutschland

    1 shared publication

Latest Publications

  • Open Access

    Peritonsillar abscess in children: A retrospective analysis on surgical and antimicrobial approaches

    by Stefan Alexander Rudhart, Thorsten Send, Maike Tilk, Barbara Leggewie, Franziska Bosse, Klaus Eichhorn, Sebastian Strieth, Stephan Hoch, Alexander Philippe Maas

    Background: Peritonsillar abscess (PTA) is a prevalent infection for specialists in otorhinolaryngology and pediatric primary care providers, that has the potential to cause severe complications. The aim of this study is to investigate the surgical treatment of pediatric peritonsillar abscesses and to compare the risk profiles of bilateral surgery versus surgery on the affected side alone. In addition, the evaluation of the microbiological smears obtained intraoperatively should provide information on whether the calculated antibiotic therapy adequately covers the microbial spectrum. Methods: We conducted a retrospective analysis of pediatric patients (n = 150), who were treated for PTA between 2009 and 2024 by unilateral tonsillectomy (UTE) or bilateral tonsillectomy (BTE). Patient charts were analyzed regarding risk of bleeding, occurrence of other complications, recurrence rates in case of UTE as well as microbiological flora and antibiotic treatment. Results: Postoperative bleeding did not differ significantly between both groups. In 4.4% of the patients treated by UTE a recurrent PTA was found. No other severe complications after surgical treatment were found. Antibiotic treatment mainly relied on Cefuroxime and Ampicillin-Sulbactam, which is in accordance with the detected microbiological flora. Conclusions: No relevant differences were found with regard to the complication rate between UTE und BTE in pediatric patients. Broad-spectrum antibiotics were used in accordance with the detected microbiological flora. Since 2019, calculated antibiotic therapy with Ampicillin-Sulbactam has been the treatment of choice for pediatric PTA.


  • Open Access

    Analysis of bacterial contamination and the effectiveness of UV light-based reprocessing of everyday medical devices

    by Stefan Alexander Rudhart, Frank Günther, Laura Isabel Dapper, Francesca Gehrt, Boris Alexander Stuck, Stephan Hoch

    Background: The reprocessing of daily used medical devices is often inadequate, making them a potential source of infection. In addition, there are usually no consistent and technically standardized procedures available for this purpose. Hence, the aim of this study is to analyze the bacterial contamination and the effectiveness of Ultraviolet light-based (UV light-based) reprocessing of daily used medical devices. Material and methods: Six different everyday medical devices (20 each; stethoscopes, tourniquets, bandage scissors, reflex hammers, tuning forks, and nystagmus glasses) were tested for bacterial contamination. All medical devices were then exposed to UV-C light for 25 seconds. Medical devices with a smooth surface were pre-cleaned with a water-based wipe. Contact samples were taken before and after reprocessing. Results: Immediately after clinical use, 104 of 120 contact samples showed an average bacterial contamination of 44.8±64.3 colony forming units (CFU) (0–300 CFU), also including potentially pathogenic bacteria. Two further culture media were completely overgrown with potentially pathogenic bacteria. The stethoscopes were found to have the highest average contamination of 90±91.6 CFU. After reprocessing, 118 of 120 samples were sterile, resulting in an average residual contamination of 0.02±0.1 CFU in two samples, whereby only bacteria of the ordinary skin flora were found. Conclusion: The present study shows the potentially clinically relevant bacterial contamination of everyday used medical devices. The reprocessing method tested here using UV light appears to be a suitable method for disinfection, especially for objects that up to now have been difficult to disinfect or cannot be disinfected in a standardized manner.


  • Open Access

    UV-C Light-Based Surface Disinfection: Analysis of Its Virucidal Efficacy Using a Bacteriophage Model

    by Stefan A. Rudhart, Frank Günther, Laura Dapper, Boris A. Stuck, Stephan Hoch

    Background: The reprocessing of medical devices has become more complex due to increasing hygiene requirements. Previous studies showed satisfactory bactericidal disinfection effects of UV-C light in rigid and flexible endoscopes. Especially in the context of the current COVID-19 pandemic, virucidal properties are of high importance. In the present study, the virucidal efficacy of UV-C light surface disinfection was analyzed. Methods: MS-2 bacteriophages were applied to the test samples and irradiated by UV-C light using the UV Smart D25 device; unirradiated test samples were used as controls. A dilution series of the samples was mixed with 1 × 108 Escherichia coli and assayed. Results: 8.6 × 1012 pfu could be harvested from the unprocessed test samples. In the control group without UV-C exposure, a remaining contamination of 1.2 × 1012 pfu was detected, resulting in a procedural baseline reduction rate with a LOG10 reduction factor of 0.72. The LOG10 reduction factor was found to be 3.0 after 25 s of UV-C light exposure. After 50 and 75 s of UV-C radiation LOG10 reduction factors 4.2 and 5.9, respectively, were found, with all reductions being statistically significantly different to baseline. Conclusions: The tested UV system seems to provide a significant virucidal effect after a relatively short irradiation time.


  • Clinical Impact of CYFRA 21-1 a Marker for Treatment Failure in Patients With Oropharyngeal Cancer Treated by Radio(chemo)therapy

    by Stefan A. Rudhart, Philipp Langen, Kruthika Thangavelu, Francesca Gehrt, Petar Stankovic, Thomas Wilhelm, Boris A. Stuck, Stephan Hoch

    Background: Primary radio(chemo)therapy [R(C)T] is a treatment option for advanced oropharyngeal squamous cell carcinoma (OSCC). Nevertheless, early diagnostics of treatment failure is problematic. Cytokeratin fragment 19 (CYFRA 21-1), an established marker in the management of pulmonary cancer, might be helpful here. Hence, in this study the impact of CYFRA 21-1 as an indicator for treatment failure and tumor recurrence (TR) in OSCC after R(C)T was analyzed. Patients and Methods: The data of 77 patients with advanced OSCC and R(C)T were retrospectively examined. For determination of CYFRA 21-1 at the time of diagnosis and after R(C)T, an electrochemiluminescence immunoassay was used. Tumor residuals and tumor recurrence were pathologically verified after detection by radiological imaging and endoscopy. The mean follow-up was 44.4 months. Results: After R(C)T, 48 (62%) patients showed locoregional control and 29 (38%) patients experienced locoregional failure. No statistical difference in the CYFRA 21-1 level between groups both before (p=0.75) and after R(C)T (p=0.85) was found. Nevertheless, in cases of TR in follow-up, the CYFRA 21-1 level was significantly higher (p≤0.01). The occurrence of TR was significantly associated with a CYFRA 21-1 elevation at this time (p≤0.01). However, CYFRA 21-1 failed to show a suitable discriminative ability for TR (area under the curve=0.57). Conclusion: In OSCC, CYFRA 21-1 does not seem to be a useful marker for locoregional failure after R(C)T. Nevertheless, a higher level immediately after R(C)T and in the further course of the disease may be associated with TR in individual patients.


  • Open Access

    UV light-based reprocessing of flexible endoscopes without working channel in Oto-Rhino-Laryngology: an effective method?

    by Stefan A. Rudhart, Frank Günther, Laura Dapper, Kruthika Thangavelu, Urban W. Geisthoff, Petar Stankovic, Thomas Wilhelm, Boris A. Stuck, Stephan Hoch

    Background: Reprocessing of flexible endoscopes (FEs) is often expensive, time consuming, and becomes increasingly complex, due to rising demands of hygiene. After beneficial results in reprocessing of rigid endoscopes using Impelux™ UV-C light technology, we tested the same method for reprocessing of FEs without working channel. Materials and methods: Testing was performed on FEs without working channel after routine clinical use (transnasal flexible endoscopy). Disinfection consisted of mechanical precleaning and 60 s exposure to Impelux™ UV-C light technology. Bacterial contamination was tested on 50 FEs before and after disinfection. Further 50 FEs regarding protein residuals. The absolute effectiveness of the D60 was tested on 50 test bodies (RAMS) with a standardized contamination of 107 colony-forming units (CFU) of Enterococcus faecium. Results: The FEs were contaminated with a high average value of 916.7 CFU (± 1057 CFU) after clinical usage. After reprocessing, an average contamination of 2.8 CFU (± 1.6) on 14% (n = 7) of the FEs was detected consisting of non-pathogenic species, the remaining FE were sterile. After reprocessing, all FEs were protein-free (< 1 μg). The artificially contaminated test bodies showed no remaining bacterial contamination after disinfection, resulting in an average absolute germ reduction of about 107 CFU. Conclusion: Impelux™ UV-C light technology efficiently reduces bacterial contamination of FEs and might be useful in daily practice.


  • Anti-IgE: Einsatz auch bei allergischer Rhinitis?

    by O. Pfaar, F. Gehrt, H. Li, S.A. Rudhart, A. Nastev, B.A. Stuck, S. Hoch