Yannick Antoine Abanda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yannick Antoine Abanda has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Aristide Tolok Nelem
Higher Technical Teachers’ Training College of the University of Ebolowa, Ebolowa, Cameroon
3 shared publications - Pierre Ele
University of Yaoundé I
3 shared publications - Achille Melingui
Department of Electrical and Telecommunications Engineering, Ecole Nationale Suprieure Polytechnique, University of Yaound 1, Yaound, Cameroon
2 shared publications - Mathieu Jean Pierre Pesdjock
University of Ebolowa
2 shared publications Alain Tiedeu
National Advanced School of Engineering, LETS PO Box 8390 Yaoundé Cameroon
1 shared publication- Alain Tiedeu
Instrumentation, Signal and Image Laboratory, National Advanced School of Engineering, University of Yaoundé I, Yaoundé, Cameroon
1 shared publication
Latest Publications
- Open Access
- 30 September 2026
- Published by Politechnika Lubelska in Applied Computer Science
- Vol. 22 (3) , 196-218
Implementation of an IEC 61215-oriented photovoltaic module test emulator with integrated predictive maintenance capabilities
This paper presents a hybrid software-based framework for photovoltaic (PV) testing, monitoring, and predictive maintenance that combines a physically validated PV emulator with data-driven diagnostic models. The emulator reproduces selected IEC 61215-inspired test scenarios, including electrical characterisation, irradiance/temperature variations, simulated accelerated ageing, and electrical fault scenarios—without relying on real solar irradiation, enabling realistic I–V and P–V curve generation under controlled settings for performance assessment and algorithm validation. Note that the emulator is a complementary validation tool and does not substitute for formal IEC 61215 certification. Building on this emulator, a two-stage intelligent monitoring architecture is proposed. First, an unsupervised autoencoder learns normal PV behaviour and detects anomalies by analysing reconstruction errors. It shows strong discriminative capability, achieving a high ROC–AUC while remaining robust across varying environmental conditions, thereby enabling early detection of abrupt faults and progressive degradation. Second, a supervised bidirectional gated recurrent unit (BiGRU) model performs fault classification by explicitly exploiting temporal dependencies in electrical signals. The BiGRU classifier achieves an overall accuracy exceeding 99%, with high class-wise precision and recall across multiple fault categories, including resistive faults, degradation, soiling, and severe electrical failures. The framework is validated on emulator-based and analytically derived datasets (Sandia, Madison, Cenerg models), demonstrating strong generalisation and stability across operating conditions; field validation on real PV installations is identified as a key next step. Overall, integrating physical emulation, unsupervised anomaly detection, and supervised temporal classification provides a robust and scalable predictive maintenance solution for PV installations, particularly in environments with high climatic variability.
- 30 September 2026
- Published by Politechnika Lubelska in Applied Computer Science
- Vol. 22 (3) , 196-218
Open AccessImplementation of an IEC 61215-oriented photovoltaic module test emulator with integrated predictive maintenance capabilities
This paper presents a hybrid software-based framework for photovoltaic (PV) testing, monitoring, and predictive maintenance that combines a physically validated PV emulator with data-driven diagnostic models. The emulator reproduces selected IEC 61215-inspired test scenarios, including electrical characterisation, irradiance/temperature variations, simulated accelerated ageing, and electrical fault scenarios—without relying on real solar irradiation, enabling realistic I–V and P–V curve generation under controlled settings for performance assessment and algorithm validation. Note that the emulator is a complementary validation tool and does not substitute for formal IEC 61215 certification. Building on this emulator, a two-stage intelligent monitoring architecture is proposed. First, an unsupervised autoencoder learns normal PV behaviour and detects anomalies by analysing reconstruction errors. It shows strong discriminative capability, achieving a high ROC–AUC while remaining robust across varying environmental conditions, thereby enabling early detection of abrupt faults and progressive degradation. Second, a supervised bidirectional gated recurrent unit (BiGRU) model performs fault classification by explicitly exploiting temporal dependencies in electrical signals. The BiGRU classifier achieves an overall accuracy exceeding 99%, with high class-wise precision and recall across multiple fault categories, including resistive faults, degradation, soiling, and severe electrical failures. The framework is validated on emulator-based and analytically derived datasets (Sandia, Madison, Cenerg models), demonstrating strong generalisation and stability across operating conditions; field validation on real PV installations is identified as a key next step. Overall, integrating physical emulation, unsupervised anomaly detection, and supervised temporal classification provides a robust and scalable predictive maintenance solution for PV installations, particularly in environments with high climatic variability.
- Open Access
- 7 September 2026
- Published by Universe Scientific Publishing Pte. Ltd. in Clean Energy Science and Technology
Power quality analysis and energy consumption monitoring across hospitals in Cameroon
The quality of electrical supply is the main cause of premature failure of biomedical equipment in Cameroon, where nearly 95% of hospital devices are imported and designed to operate under stable mains conditions. This study, based on real hospital data, utilises data collected by CURES (University Centre for Energy Research in Healthcare) in four Cameroonian hospitals. The data collection yielded 3,474 ten-minute intervals. A model-free algorithm enabled, in turn: the profiling of regulatory compliance against the EN 50160 and IEEE 519-2014 standards; the detection of anomalies via SPE and Hotelling’s T2 statistics derived from PCA; the localization of faults through residual structuring; unsupervised classification using the K-means method validated by the elbow and silhouette criteria; and finally, the modelling of temporal dependence via a robust vector autoregressive model with parameter estimation based on the M-estimator. Four disturbance profiles were identified. A Spearman’s correlation of ρ = −1.00 between anomaly rates and compliance scores indicates the internal consistency between the compliance scoring and the anomaly detection outputs. With a frequency compliance rate of 28.9% and a score of 47.8%, Djoum Hospital is the most critical site, while Obala achieved the highest score (72.6%). These results highlight the urgent need to deploy reactive compensation and frequency stabilisation systems in the rural hospital facilities included in this study.
- 7 September 2026
- Published by Universe Scientific Publishing Pte. Ltd. in Clean Energy Science and Technology
Open AccessPower quality analysis and energy consumption monitoring across hospitals in Cameroon
The quality of electrical supply is the main cause of premature failure of biomedical equipment in Cameroon, where nearly 95% of hospital devices are imported and designed to operate under stable mains conditions. This study, based on real hospital data, utilises data collected by CURES (University Centre for Energy Research in Healthcare) in four Cameroonian hospitals. The data collection yielded 3,474 ten-minute intervals. A model-free algorithm enabled, in turn: the profiling of regulatory compliance against the EN 50160 and IEEE 519-2014 standards; the detection of anomalies via SPE and Hotelling’s T2 statistics derived from PCA; the localization of faults through residual structuring; unsupervised classification using the K-means method validated by the elbow and silhouette criteria; and finally, the modelling of temporal dependence via a robust vector autoregressive model with parameter estimation based on the M-estimator. Four disturbance profiles were identified. A Spearman’s correlation of ρ = −1.00 between anomaly rates and compliance scores indicates the internal consistency between the compliance scoring and the anomaly detection outputs. With a frequency compliance rate of 28.9% and a score of 47.8%, Djoum Hospital is the most critical site, while Obala achieved the highest score (72.6%). These results highlight the urgent need to deploy reactive compensation and frequency stabilisation systems in the rural hospital facilities included in this study.
- Open Access
- 3 September 2023
- Published by MDPI AG in Inventions
- Vol. 8 (5) , 113
Contribution to the Development of a Smart Ultrasound Scanner: Design and Analysis of the High-Voltage Power Supply of the Transmitter
A smart ultrasound scanner plays an important role in the transition to point-of-care imaging. DC–DC bipolar converters are essential in the generation of the ultrasound burst signal as they power the piezoelectric transducer. The conventional bipolar converter has minimal output gain and high-voltage stress, and the longer duty cycle on the semiconductors produces high conduction losses and reduces the efficiency of the system. The transmitter supply voltage is minimal, necessitating the use of high-gain bipolar converters. This proposed study is concerned with the development of an improved high-output voltage gain symmetric bipolar DC–DC converter topology which may be suitable for applications such as powering a smart ultrasound scanner transmitter. The proposed converter combines the conventional single-ended primary inductor converter (SEPIC) with a voltage multiplier cell (VMC) to improve voltage gain, transistor duty cycle, efficiency, and reliability. The present study describes the working principle of the proposed converter. The analysis of the voltage gain is carried out in continuous current mode (CCM) and discontinuous current mode (DCM), taking into account the nonidealities of the device. The simulation of the proposed system is carried out in the numerical environment Matlab/Simulink in order to verify its characteristics. A prototype model is realized and the experimental study presented validates the theoretical arguments and simulations. Due to the advantages of continuous input current, self-balancing bipolar outputs, and small component size, the proposed converter is a suitable choice for smart ultrasound transmitters.
- 3 September 2023
- Published by MDPI AG in Inventions
- Vol. 8 (5) , 113
Open AccessContribution to the Development of a Smart Ultrasound Scanner: Design and Analysis of the High-Voltage Power Supply of the Transmitter
A smart ultrasound scanner plays an important role in the transition to point-of-care imaging. DC–DC bipolar converters are essential in the generation of the ultrasound burst signal as they power the piezoelectric transducer. The conventional bipolar converter has minimal output gain and high-voltage stress, and the longer duty cycle on the semiconductors produces high conduction losses and reduces the efficiency of the system. The transmitter supply voltage is minimal, necessitating the use of high-gain bipolar converters. This proposed study is concerned with the development of an improved high-output voltage gain symmetric bipolar DC–DC converter topology which may be suitable for applications such as powering a smart ultrasound scanner transmitter. The proposed converter combines the conventional single-ended primary inductor converter (SEPIC) with a voltage multiplier cell (VMC) to improve voltage gain, transistor duty cycle, efficiency, and reliability. The present study describes the working principle of the proposed converter. The analysis of the voltage gain is carried out in continuous current mode (CCM) and discontinuous current mode (DCM), taking into account the nonidealities of the device. The simulation of the proposed system is carried out in the numerical environment Matlab/Simulink in order to verify its characteristics. A prototype model is realized and the experimental study presented validates the theoretical arguments and simulations. Due to the advantages of continuous input current, self-balancing bipolar outputs, and small component size, the proposed converter is a suitable choice for smart ultrasound transmitters.
- Open Access
- 14 July 2021
- Published by Hindawi Limited in Security and Communication Networks
- Vol. 2021, 1-16
Image Encryption with Fusion of Two Maps
In this paper, we propose a fusion technique for image encryption combining two maps and generate a new optimized map by fusing Hartley and Duffing chaotic oscillators. In order to measure and quantify the amount of chaos present in data sequences, the resultant map is tested by a new method of nonlinear time series analysis. This test ensures its robustness during its use to construct an encrypted image when combined with some mathematical function that we have designed. The cryptosystem was tested on images such as Lena, Barbara, Mandrill, and Man. The results were compared to those in the literature and proved satisfactory.
- 14 July 2021
- Published by Hindawi Limited in Security and Communication Networks
- Vol. 2021, 1-16
Open AccessImage Encryption with Fusion of Two Maps
In this paper, we propose a fusion technique for image encryption combining two maps and generate a new optimized map by fusing Hartley and Duffing chaotic oscillators. In order to measure and quantify the amount of chaos present in data sequences, the resultant map is tested by a new method of nonlinear time series analysis. This test ensures its robustness during its use to construct an encrypted image when combined with some mathematical function that we have designed. The cryptosystem was tested on images such as Lena, Barbara, Mandrill, and Man. The results were compared to those in the literature and proved satisfactory.
- Open Access
- 1 October 2016
- Published by Institution of Engineering and Technology (IET) in IET Image Processing
- Vol. 10 (10) , 742-750
Image encryption by chaos mixing
The need for image encryption is constantly on the rise and has led to the emergence of many techniques in literature. In recent years, many chaos‐based encryption techniques have developed with more or less success. In this study, we suggest one such approach using two oscillators. Mixed chaotic maps from the Colpitts and Duffing oscillators were used to encrypt images, which helped to increase the key space to 2 448 ≃ 7.26 × 10 134 . The authors also succeeded to reduce the encryption time by saving the mixed chaotic maps and reusing them as need arose. The proposed system was tested on well‐known images like Lena, NebulaM83, Mandrill and Clown.
- 1 October 2016
- Published by Institution of Engineering and Technology (IET) in IET Image Processing
- Vol. 10 (10) , 742-750
Open AccessImage encryption by chaos mixing
The need for image encryption is constantly on the rise and has led to the emergence of many techniques in literature. In recent years, many chaos‐based encryption techniques have developed with more or less success. In this study, we suggest one such approach using two oscillators. Mixed chaotic maps from the Colpitts and Duffing oscillators were used to encrypt images, which helped to increase the key space to 2 448 ≃ 7.26 × 10 134 . The authors also succeeded to reduce the encryption time by saving the mixed chaotic maps and reusing them as need arose. The proposed system was tested on well‐known images like Lena, NebulaM83, Mandrill and Clown.