Ryan Herbst
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ryan Herbst has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Larry Ruckman
SLAC National Accelerator Laboratory, 2575 Sand Hill Road, M/S 96, Menlo Park, CA 94025, U.S.A.
4 shared publications - Abhilasha Dave
SLAC National Accelerator Laboratory
2 shared publications - Amirari Diego
RadiaBeam Technologies LLC 2 , Santa Monica, California 90404
2 shared publications - Andrew Ames
Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, Massachusetts 02138, USA
2 shared publications - Angelo Dragone
SLAC National Accelerator Laboratory
2 shared publications - Brian Mong
SLAC National Accelerator Laboratory Palo Alto, CA United States
2 shared publications
Latest Publications
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , P08017
Discrete wavelet transform for serial X-ray crystallography image segmentation
Upcoming LCLS-II/II-HE operation at repetition rates approaching 1 MHz demands on-detector data reduction to manage the resulting data volumes. We present a 2D discrete wavelet transform (DWT) pre-processing algorithm that segments background scatter from crystal diffraction in serial crystallography images, enabling early data analysis and, when combined with peak finding, lossy compression by transmitting only the identified diffraction peaks. The method zeroes the approximation (LL) coefficients of a multi-level Haar wavelet decomposition and reconstructs from detail subbands only, exploiting the natural separation of smooth background and sharp Bragg peaks in the wavelet domain. Evaluated on 100 simulated nanoBragg frames with known ground truth, the pipeline achieves F 1 ≈ 0.96 at four decomposition levels ( J = 4), substantially outperforming the established peakfinder8 algorithm ( F 1 ≈ 0.37) in both precision ( P ≈ 1.00 vs. 0.94) and recall ( R ≈ 0.92 vs. 0.24). A comparison of 12 wavelet families confirms that Haar is optimal for Bragg-peak detection due to its minimal filter support. Downstream crystallographic analysis performed on real ePix10kA data shows that CC* and R split converge at J = 4 and track the unprocessed baseline through the practical resolution limit. Under added noise exceeding ∼ 50 ADU, the current pipeline's precision degrades significantly more than that of the pf8 algorithm, exposing a limitation of the proposed strategy. We also demonstrate an FPGA implementation of the DWT filters on an Alveo U200 at 200 MHz, with a projected resource footprint compatible with integration into the upcoming ePix UHR firmware and a path to on-detector ASIC implementation in SparkPix detector family.
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , P08017
Discrete wavelet transform for serial X-ray crystallography image segmentation
Upcoming LCLS-II/II-HE operation at repetition rates approaching 1 MHz demands on-detector data reduction to manage the resulting data volumes. We present a 2D discrete wavelet transform (DWT) pre-processing algorithm that segments background scatter from crystal diffraction in serial crystallography images, enabling early data analysis and, when combined with peak finding, lossy compression by transmitting only the identified diffraction peaks. The method zeroes the approximation (LL) coefficients of a multi-level Haar wavelet decomposition and reconstructs from detail subbands only, exploiting the natural separation of smooth background and sharp Bragg peaks in the wavelet domain. Evaluated on 100 simulated nanoBragg frames with known ground truth, the pipeline achieves F 1 ≈ 0.96 at four decomposition levels ( J = 4), substantially outperforming the established peakfinder8 algorithm ( F 1 ≈ 0.37) in both precision ( P ≈ 1.00 vs. 0.94) and recall ( R ≈ 0.92 vs. 0.24). A comparison of 12 wavelet families confirms that Haar is optimal for Bragg-peak detection due to its minimal filter support. Downstream crystallographic analysis performed on real ePix10kA data shows that CC* and R split converge at J = 4 and track the unprocessed baseline through the practical resolution limit. Under added noise exceeding ∼ 50 ADU, the current pipeline's precision degrades significantly more than that of the pf8 algorithm, exposing a limitation of the proposed strategy. We also demonstrate an FPGA implementation of the DWT filters on an Alveo U200 at 200 MHz, with a projected resource footprint compatible with integration into the upcoming ePix UHR firmware and a path to on-detector ASIC implementation in SparkPix detector family.
- 16 April 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 228
Real-time plasma monitoring framework for advanced plasma control and ML-research in DIII-D
- 16 April 2026
- Published by Elsevier in Fusion Engineering and Design
- Vol. 228
Real-time plasma monitoring framework for advanced plasma control and ML-research in DIII-D
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
A compact low-level RF control system for advanced concept compact electron linear accelerator
A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight, and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analog upconversion and downconversion. Compared with the conventional heterodyne based architecture used for the LLRF system of a linear accelerator (LINAC), the elimination of analog mixers can significantly reduce the size and weight of the system, especially with LINAC requiring a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1° on the flattop of a 2 μs RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. This paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.
- 1 September 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (9)
A compact low-level RF control system for advanced concept compact electron linear accelerator
A compact low-level RF (LLRF) control system based on RF system-on-chip (RFSoC) technology has been designed for the Advanced Concept Compact Electron Linear-accelerator (ACCEL) program, which has challenging requirements in both RF performance and size, weight, and power consumption (SWaP). The compact LLRF solution employs the direct RF sampling technique of RFSoC, which samples the RF signals directly without any analog upconversion and downconversion. Compared with the conventional heterodyne based architecture used for the LLRF system of a linear accelerator (LINAC), the elimination of analog mixers can significantly reduce the size and weight of the system, especially with LINAC requiring a larger number of RF channels. Based on the requirements of ACCEL, a prototype LLRF platform has been developed, and the control schemes have been proposed. The prototype LLRF system demonstrated magnitude and phase fluctuation levels below 1% and 1° on the flattop of a 2 μs RF pulse. The LLRF control schemes proposed for ACCEL are implemented with a prototype hardware platform. This paper will introduce the new compact LLRF solution and summarize a selection of experimental test results of the prototype itself and with the accelerating structure cavities designed for ACCEL.
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system
Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. The NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C3) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C3. The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.
- 1 April 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (4)
High-power test of a C-band linear accelerating structure with an RFSoC-based LLRF system
Normal conducting linear particle accelerators consist of multiple rf stations with accelerating structure cavities. Low-level rf (LLRF) systems are employed to set the phase and amplitude of the field in the accelerating structure and to compensate for the pulse-to-pulse fluctuation of the rf field in the accelerating structures with a feedback loop. The LLRF systems are typically implemented with analog rf mixers, heterodyne-based architectures, and discrete data converters. There are multiple rf signals from each of the rf stations, so the number of rf channels required increases rapidly with multiple rf stations. With a large number of rf channels, the footprint, component cost, and system complexity of the LLRF hardware will increase significantly. To meet the design goals of being compact and affordable for future accelerators, we have designed the next-generation LLRF (NG-LLRF) with a higher integration level based on RFSoC technology. The NG-LLRF system samples rf signals directly and performs rf mixing digitally. The NG-LLRF has been characterized in loopback mode to evaluate the performance of the system and has also been tested with a standing-wave accelerating structure, a prototype for the Cool Copper Collider (C3) with a peak rf power level up to 16.45 MW. The loopback test demonstrated amplitude fluctuation below 0.15% and phase fluctuation below 0.15°, which are considerably better than the requirements of C3. The rf signals from the different stages of the accelerating structure at different power levels are measured by the NG-LLRF, which will be critical references for the control algorithm designs. The NG-LLRF also offers flexibility in waveform modulation, so we have used rf pulses with various modulation schemes, which could be useful for controlling some of the rf stations in accelerators. In this paper, the high-power test results at different stages of the test setup will be summarized, analyzed, and discussed.
- 1 December 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (12) , P12026
Development of a novel bunch oscillation recorder with RFSoC technology
The SuperKEKB accelerator is designed to achieve unprecedented luminosity levels, but this goal is currently hindered by Sudden Beam Loss (SBL) events. These events not only obstruct luminosity improvement but also pose a significant risk to accelerator components, the Belle II detectors, and the superconducting focusing system, potentially leading to severe damage and quenching of the superconducting system. To address this critical challenge, we have developed a novel Bunch Oscillation Recorder (BOR) based on RFSoC technology. The BOR has demonstrated high precision with a position resolution of 0.03 mm, making it a powerful tool for real-time beam monitoring. In its initial deployment, the BOR successfully recorded multiple SBL events, providing valuable data for further analysis. By strategically positioning BORs at the suspected points of SBL origin, we aim to directly identify sources of beam instability. We anticipate that this portable, high-speed BOR monitor will play a crucial role in resolving the SBL issue, ultimately helping achieve SuperKEKB's luminosity targets.
- 1 December 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (12) , P12026
Development of a novel bunch oscillation recorder with RFSoC technology
The SuperKEKB accelerator is designed to achieve unprecedented luminosity levels, but this goal is currently hindered by Sudden Beam Loss (SBL) events. These events not only obstruct luminosity improvement but also pose a significant risk to accelerator components, the Belle II detectors, and the superconducting focusing system, potentially leading to severe damage and quenching of the superconducting system. To address this critical challenge, we have developed a novel Bunch Oscillation Recorder (BOR) based on RFSoC technology. The BOR has demonstrated high precision with a position resolution of 0.03 mm, making it a powerful tool for real-time beam monitoring. In its initial deployment, the BOR successfully recorded multiple SBL events, providing valuable data for further analysis. By strategically positioning BORs at the suspected points of SBL origin, we aim to directly identify sources of beam instability. We anticipate that this portable, high-speed BOR monitor will play a crucial role in resolving the SBL issue, ultimately helping achieve SuperKEKB's luminosity targets.
- 1 August 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (08) , P08023
Embedded FPGA developments in 130 nm and 28 nm CMOS for machine learning in particle detector readout
Embedded field programmable gate array (eFPGA) technology allows the implementation of reconfigurable logic within the design of an application-specific integrated circuit (ASIC). This approach offers the low power and efficiency of an ASIC along with the ease of FPGA configuration, particularly beneficial for the use case of machine learning in the data pipeline of next-generation collider experiments. An open-source framework called “FABulous” was used to design eFPGAs using 130 nm and 28 nm CMOS technology nodes, which were subsequently fabricated and verified through testing. The capability of an eFPGA to act as a front-end readout chip was assessed using simulation of high energy particles passing through a silicon pixel sensor. A machine learning-based classifier, designed for reduction of sensor data at the source, was synthesized and configured onto the eFPGA. A successful proof-of-concept was demonstrated through reproduction of the expected algorithm result on the eFPGA with perfect accuracy. Further development of the eFPGA technology and its application to collider detector readout is discussed.
- 1 August 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (08) , P08023
Embedded FPGA developments in 130 nm and 28 nm CMOS for machine learning in particle detector readout
Embedded field programmable gate array (eFPGA) technology allows the implementation of reconfigurable logic within the design of an application-specific integrated circuit (ASIC). This approach offers the low power and efficiency of an ASIC along with the ease of FPGA configuration, particularly beneficial for the use case of machine learning in the data pipeline of next-generation collider experiments. An open-source framework called “FABulous” was used to design eFPGAs using 130 nm and 28 nm CMOS technology nodes, which were subsequently fabricated and verified through testing. The capability of an eFPGA to act as a front-end readout chip was assessed using simulation of high energy particles passing through a silicon pixel sensor. A machine learning-based classifier, designed for reduction of sensor data at the source, was synthesized and configured onto the eFPGA. A successful proof-of-concept was demonstrated through reproduction of the expected algorithm result on the eFPGA with perfect accuracy. Further development of the eFPGA technology and its application to collider detector readout is discussed.
- Open Access
- 1 January 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 014712
SLAC microresonator RF (SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.
- 1 January 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 014712
Open AccessSLAC microresonator RF (SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.
- Open Access
- 5 August 2021
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 6 (3) , e26047
A Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing
Background: The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. Objective: We aimed to develop an acute shortage ventilator. Methods: The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. Results: The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. Conclusions: The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured.
- 5 August 2021
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 6 (3) , e26047
Open AccessA Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing
Background: The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. Objective: We aimed to develop an acute shortage ventilator. Methods: The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. Results: The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. Conclusions: The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured.
- Open Access
- 30 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
A Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing (Preprint)
BACKGROUND The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. OBJECTIVE We aimed to develop an acute shortage ventilator. METHODS The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. RESULTS The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. CONCLUSIONS The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured. CLINICALTRIAL
- 30 November 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessA Simple Ventilator Designed To Be Used in Shortage Crises: Construction and Verification Testing (Preprint)
BACKGROUND The COVID-19 pandemic has demonstrated the possibility of severe ventilator shortages in the near future. OBJECTIVE We aimed to develop an acute shortage ventilator. METHODS The ventilator was designed to mechanically compress a self-inflating bag resuscitator, using a modified ventilator patient circuit, which is controlled by a microcontroller and an optional laptop. It was designed to operate in both volume-controlled mode and pressure-controlled assist modes. We tested the ventilator in 4 modes using an artificial lung while measuring the volume, flow, and pressure delivered over time by the ventilator. RESULTS The ventilator was successful in reaching the desired tidal volume and respiratory rates specified in national emergency use resuscitator system guidelines. The ventilator responded to simulated spontaneous breathing. CONCLUSIONS The key design goals were achieved. We developed a simple device with high performance for short-term use, made primarily from common hospital parts and generally available nonmedical components to avoid any compatibility or safety issues with the patient, and at low cost, with a unit cost per ventilator is less than $400 US excluding the patient circuit parts, that can be easily manufactured. CLINICALTRIAL