SBSerhii Bezruchenko

Serhii Bezruchenko

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Serhii Bezruchenko has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental study on the stability of osteosynthesis for a fracture of the suprahumeral process and the scapular spine with a bone tissue defect using bone plates

    by O.V. Dolhopolov, S.O. Bezruchenko, R.V. Saliuk, V.L. Suvorov, O.D. Karpinska, M.YU. Karpinsky

    Background. The frequency of scapular fractures in military personnel who were in the combat zone is approximately 20 times higher than among the civilian population. The probable cause of fixation failures is insufficient stability of the structure, especially in cases of bone tissue defect. One of the possible ways to increase the strength of osteosynthesis is the use of two plates located in an orthogonal plane. The purpose was to study in an experiment the stabilizing properties of different variants of osteosynthesis for fragments of a fracture of the suprahumeral process and the scapular spine with a bone tissue defect using bone plates. Materials and methods. The study was performed on anatomical models of the scapula made of high-density polyurethane. To reproduce the fracture, a simulated defect of the suprahumeral process and the scapular spine with a length of 20 mm was created. Two variants of osteosynthesis were studied — with one and two plates (5 samples each). The amount of movement of the scapular fragments under the influence of loading in two planes, vertical and horizontal, was determined. The loading was increased from 0 to 50 N in increments of 10 N. Results. Osteosynthesis of the suprahumeral process of the scapula with one plate provides stable fixation of the fragments only in the vertical plane, when the loading acts perpendicular to the plane of the bone plate. In this case, the displacement of the process is possible only if the metal plate is deformed. Under the influence of the load in the horizontal plane, the largest displacements are noted, since the force acts parallel to the plane of the plate, and the resistance to it is provided exclusively by the fixing screws. Thus, the disadvantage of osteosynthesis with one plate is its effectiveness only in counteracting loads in the vertical plane. The imposition of two plates on the upper and front surfaces of the humeral process ensures stability of the structure both under vertical and horizontal loads. The small difference in the displacement values between these options is due to the geometric features of the plates: the lateral plate had a smaller thickness compared to the upper one, which reduced its resistance to horizontal loads. Conclusions. The stability of the model of fixation for a fracture of the humeral process and the spine of the scapula with a bone tissue defect significantly depends on the configuration of osteosynthesis and the direction of the applied load. Fixation with one plate on the upper surface of the clavicle provides relatively effective resistance to vertical loads, however, with horizontal loading, a significant increase in the movement of fragments is observed, which indicates insufficient rigidity of the structure in this plane. In contrast, fixation with two plates provides significantly smaller movements of the suprahumeral process under loads in both planes, which indicates increased rigidity and stability of the structure.

  • Open Access

    Experimental study of the stability of osteosynthesis of the clavicle with bone plates in case of a fracture of its suprahumeral end with a bone tissue defect

    by O.V. Dolhopolov, S.O. Bezruchenko, V.V. Zinchenko, V.L. Suvorov, O.D. Karpinska, M.YU. Karpinsky

    Background. Combat injuries of the suprahumeral region with clavicle fractures differ significantly from peacetime injuries. The most common approach to the treatment of clavicle nonunion is open reduction with fixation with a plate located on the upper surface of the bone, in combination with bone grafting. However, according to long-term studies, the frequency of nonunion remains at the level of 3.1–10.5 %. Objective: to study the stabilizing possibilities of the options for osteosynthesis of clavicle fragments in case of a fracture at the border of the diaphysis and the suprahumeral end with a bone tissue defect. Materials and ­methods. The stabilizing possibilities of osteosynthesis of the clavicle with bone plates were studied in case of a fracture at the border of the diaphysis and the suprahumeral end of the clavicle with a 2 cm defect, which was filled with a graft of the appropriate size and fixed with screws. Two options for osteosynthesis of the clavicle were considered: with one plate and two plates, 5 samples in each group. There was determined the value of fragment movement under the influence of bending load in two planes — vertical and horizontal. The load was increased from 0 to 50 N in steps of 10 N. Results. Osteosynthesis of the clavicle with one plate provides stable fixation of fragments only in the vertical plane, when the load acts on its suprahumeral end perpendicular to the plane of the bone plate. In this case, in order to displace the suprahumeral end, the clavicle is forced to deform a metal bone plate, which has significant strength properties. Under the influence of a load in the horizontal plane, the highest rates of movement of the suprahumeral end of the clavicle were observed. This is due to the fact that the load acts parallel to the bone plate and the resistance to the load is provided only by its fixing screws, which turns out to be insufficient. Therefore, the disadvantage of osteosynthesis with one bone plate is that it effectively counteracts loads only in one plane. Osteosynthesis of the clavicle with two bone plates located in mutually perpendicular planes ensures stability of its suprahumeral end under the influence of both vertical and horizontal loads. A small difference in the rates of movement of the suprahumeral end of the clavicle between the groups tested under the influence of vertical and horizontal loads was caused only by the factor of the geometric parameters of the plates. Conclusions. Osteosynthesis of the clavicle with one plate provides stability of its suprahumeral end only in the vertical plane. Under the influence of large loads acting in the horizontal plane, the displacement of the suprahumeral end of the clavicle can be equal to its diameter in cross section. Osteosynthesis of the clavicle with two plates located in mutually perpendicular planes provides stability of its suprahumeral end regardless of the direction of the load.


  • Open Access

    Structure and peculiarities of non-gunshot injuries of the knee joint among solders of the Armed Forces of Ukraine

    by V.V. Zinchenko, O.V. Dolhopolov, S.O. Bezruchenko, I.S. Zanko, R.V. Salyuk

    Background. Physical fitness plays a crucial role in ensuring the adequate performance of military duties, enhancing the combat capability of units, and maintaining the health of service members. Under conditions of intensive physical exertion during combat missions, marches, tactical movements, and training, the risk of musculoskeletal injuries significantly increases. The knee joints are particularly vulnerable due to the high dynamic loads they endure. Although not caused by firearms, non-combat injuries often lead to prolonged treatment, functional impairment, and temporary unfitness for duty. The purpose was to assess the structure, characteristics, and primary causes of non-combat-related knee joint injuries among servicemen of the Armed For­ces of Ukraine (AFU), and to analyse contributing risk factors. ­Materials and methods. This study analysed MRI scans and arthroscopic findings from surgical knee revisions in 83 male AFU servicemen aged 35–59 years (mean age — 45.31 ± 7.48 years), who received treatment at the Department of Severe Multistructural Trauma, SI “Institute of Traumatology and Orthopaedics of the NAMS of Ukraine” (Kyiv) in 2023–2025. Results. The data revealed a predominance of meniscal injuries (61 %), likely associated with frequent rotational loads and squatting in full tactical gear. Ligament sprains and ruptures accounted for 14 %, contusion fractures, fissures, and chondral damage for 17 %, while chronic degenerative and inflammatory joint changes made up 8 %. Conclusion. Non-combat knee injuries represent a significant proportion of musculoskeletal trauma among AFU personnel. Their prevalence is linked to intense physical exertion, limi­ted adaptation time under combat conditions, and the lack of comprehensive preventive strategies. Strengthening prevention efforts, implementing adapted training protocols, and ensuring timely diagnosis and rehabilitation can significantly reduce the risk of di­sability and facilitate faster return to duty.

  • Computer-Assisted Modeling of Greater Tubercle Transposition Effect on Stress Distribution in Shoulder

    by Sergey Strafun, Ihor Zanko, Igor Lazarev, Oleksii Dolhopolov, Serhii Bezruchenko, Maksym Skyban

    The aim of the work was to investigate the influence of the position of a fractured greater tubercle of the humerus on stress distribution in the glenohumeral joint (GHJ) at shoulder abduction by performing stress-strain analysis (SSA). A simulated 3D model of the shoulder was constructed on the basis of anatomical and anthropometric data as close as possible to real ones using the SolidWorks software package. A finite-element model (FEM) was generated in a semi-automatic mode composed mostly of tetrahedral and hexagonal elements < 1 mm in dimensions. The simulated 3D model of the shoulder, based on anatomical and anthropometric data as close as possible to the real ones, makes possible highly accurate determination of the optimal mutual position of the movable elements of the real joint individually for each specific patient, and makes it possible to accurately perform a minimally invasive surgical operation.

  • Open Access

    Retrospective analysis of patients with acromioclavicular joint dislocation treated with a specialized plate

    by O. V. Dolhopolov, M. L. Yarova, S. O. Bezruchenko

    Цель работы – определить недостатки использования Hook-пластин при повреждении акромиально-ключичного сустава на основании ретроспективного анализа лечения пациентов с этой патологией. Материалы и методы. Проведен ретроспективный анализ лечения 112 пациентов с вывихом акромиального конца ключицы, которые проходили лечение в период с 2011 по 2018 г. в условиях ГУ «Институт травматологии и ортопедии НАМН Украины». У 74 пациентов (66,1 %) выполнена фиксация акромиально-ключичного сустава специализированной пластиной Hook. Пациентов поделили на 3 клинические группы: I группа – металлофиксатор удален в срок до 4 месяцев; II группа – удаление металлофиксатора в период от 4 до 6 месяцев; III группа – удаление металлофиксаторов в период более 6 месяцев. Результаты. При оценке результатов лечения пациентов по шкале Constant–Murley перед удалением металлофиксаторов получили такие показатели: в I группе – 6,7 % хороших, 4 % удовлетворительных и неудовлетворительных результатов; во II группе – 43,2 % отличных и хороших, 9,5 % удовлетворительных результатов, в III клинической группе – 19 % отличных и хороших, 17,6 % удовлетворительных и неудовлетворительных результатов лечения. Через 6 месяцев после удаления металлофиксаторов в I группе наблюдали 8,2 % отличных и хороших, 2,7 % удовлетворительных результатов; во II группе – 52,6 % хороших и отличных результатов, в III группе – 20,3 % отличных и хороших, 16,2 % удовлетворительных и неудовлетворительных результатов лечения. Ошибки и осложнения фиксации акромиально-ключичного сустава отмечены у 36 пациентов – 18 больных с III типом вывиха и 14 больных с V типом вывиха по Rockwood. Выводы. При оценке результатов лечения по шкале Constant–Murley и Визуальной аналоговой шкале боли наилучшие результаты лечения получены в группе, где металлофиксаторы из акромиально-ключичного сустава удалены в срок от 4 до 6 месяцев. При удалении специализированной пластины в термин более чем 6 месяцев наблюдали осложнения – необратимые изменения (деформирующий артроз, дефект костной ткани акромиального отростка лопатки и др.) в акромиально-ключичном суставе.