RSR.V. Saliuk

R.V. Saliuk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


R.V. Saliuk has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental study on the stability of osteosynthesis for a fracture of the suprahumeral process and the scapular spine with a bone tissue defect using bone plates

    by O.V. Dolhopolov, S.O. Bezruchenko, R.V. Saliuk, V.L. Suvorov, O.D. Karpinska, M.YU. Karpinsky

    Background. The frequency of scapular fractures in military personnel who were in the combat zone is approximately 20 times higher than among the civilian population. The probable cause of fixation failures is insufficient stability of the structure, especially in cases of bone tissue defect. One of the possible ways to increase the strength of osteosynthesis is the use of two plates located in an orthogonal plane. The purpose was to study in an experiment the stabilizing properties of different variants of osteosynthesis for fragments of a fracture of the suprahumeral process and the scapular spine with a bone tissue defect using bone plates. Materials and methods. The study was performed on anatomical models of the scapula made of high-density polyurethane. To reproduce the fracture, a simulated defect of the suprahumeral process and the scapular spine with a length of 20 mm was created. Two variants of osteosynthesis were studied — with one and two plates (5 samples each). The amount of movement of the scapular fragments under the influence of loading in two planes, vertical and horizontal, was determined. The loading was increased from 0 to 50 N in increments of 10 N. Results. Osteosynthesis of the suprahumeral process of the scapula with one plate provides stable fixation of the fragments only in the vertical plane, when the loading acts perpendicular to the plane of the bone plate. In this case, the displacement of the process is possible only if the metal plate is deformed. Under the influence of the load in the horizontal plane, the largest displacements are noted, since the force acts parallel to the plane of the plate, and the resistance to it is provided exclusively by the fixing screws. Thus, the disadvantage of osteosynthesis with one plate is its effectiveness only in counteracting loads in the vertical plane. The imposition of two plates on the upper and front surfaces of the humeral process ensures stability of the structure both under vertical and horizontal loads. The small difference in the displacement values between these options is due to the geometric features of the plates: the lateral plate had a smaller thickness compared to the upper one, which reduced its resistance to horizontal loads. Conclusions. The stability of the model of fixation for a fracture of the humeral process and the spine of the scapula with a bone tissue defect significantly depends on the configuration of osteosynthesis and the direction of the applied load. Fixation with one plate on the upper surface of the clavicle provides relatively effective resistance to vertical loads, however, with horizontal loading, a significant increase in the movement of fragments is observed, which indicates insufficient rigidity of the structure in this plane. In contrast, fixation with two plates provides significantly smaller movements of the suprahumeral process under loads in both planes, which indicates increased rigidity and stability of the structure.

  • Open Access

    Structure and peculiarities of non-gunshot injuries of the knee joint among solders of the Armed Forces of Ukraine

    by V.V. Zinchenko, O.V. Dolhopolov, S.O. Bezruchenko, I.S. Zanko, R.V. Salyuk

    Background. Physical fitness plays a crucial role in ensuring the adequate performance of military duties, enhancing the combat capability of units, and maintaining the health of service members. Under conditions of intensive physical exertion during combat missions, marches, tactical movements, and training, the risk of musculoskeletal injuries significantly increases. The knee joints are particularly vulnerable due to the high dynamic loads they endure. Although not caused by firearms, non-combat injuries often lead to prolonged treatment, functional impairment, and temporary unfitness for duty. The purpose was to assess the structure, characteristics, and primary causes of non-combat-related knee joint injuries among servicemen of the Armed For­ces of Ukraine (AFU), and to analyse contributing risk factors. ­Materials and methods. This study analysed MRI scans and arthroscopic findings from surgical knee revisions in 83 male AFU servicemen aged 35–59 years (mean age — 45.31 ± 7.48 years), who received treatment at the Department of Severe Multistructural Trauma, SI “Institute of Traumatology and Orthopaedics of the NAMS of Ukraine” (Kyiv) in 2023–2025. Results. The data revealed a predominance of meniscal injuries (61 %), likely associated with frequent rotational loads and squatting in full tactical gear. Ligament sprains and ruptures accounted for 14 %, contusion fractures, fissures, and chondral damage for 17 %, while chronic degenerative and inflammatory joint changes made up 8 %. Conclusion. Non-combat knee injuries represent a significant proportion of musculoskeletal trauma among AFU personnel. Their prevalence is linked to intense physical exertion, limi­ted adaptation time under combat conditions, and the lack of comprehensive preventive strategies. Strengthening prevention efforts, implementing adapted training protocols, and ensuring timely diagnosis and rehabilitation can significantly reduce the risk of di­sability and facilitate faster return to duty.