On the design and manufacturing of miniaturized microstripline power splitters for driving multicoil transmit arrays with arbitrary ratios at 7 T
- 1 August 2022
- journal article
- research article
- Published by Wiley in NMR in Biomedicine
- Vol. 35 (11) , e4793
Abstract
The purpose of the current study was to implement unequal microstrip power splitters for parallel transmission at 7 T that are optimized for size and loss and that can be configured for a wide range of power ratios. The splitters will enable the use of more transmit coils without a corresponding increase in the number of transmit channels or amplifiers to control specific absorption rate, shorten RF pulses, and shim inhomogeneous RF fields. Wilkinson unequal power splitters based on a novel microstrip network design were optimized to minimize their size under 8 cm in length and 9 cm in width, enabling them to be included in coil housing or cascaded in multiple stages. Splitters were designed and constructed for a wide range of output power ratios at 298 MHz. Simulations and bench tests were performed for each ratio, and a methodology was established to adapt the designs to other ratios and frequencies. The designs and code are open source and can be reproduced as is or reconfigured. The single‐stage designs achieved good matches and isolations between output ports (worst isolation −15.9 dB, worst match −15.1 dB). A two‐stage cascaded (one input to four outputs) power splitter with 1:2.5, 1:10, 1:3, and 1:6 ratio outputs was constructed. The worst isolation between output ports was −19.7 dB in simulation and the worst match of the three ports was −17.8 dB. The measured ratios for one‐ and two‐stage boards were within 10% of the theoretical ratios. The power‐handling capability of the smallest trace was approximately 70 W. Power loss for the one‐ and two‐stage boards ranged from 1% to 3% in simulation compared with 5.1% to 7.2% on the bench. It was concluded that Wilkinson unequal microstrip power splitters can be implemented with a small board size (low height) and low loss, and across a wide range of output power ratios. The splitters can be cascaded in multiple stages while maintaining the expected ratios and low loss. This will enable the construction of large fixed transmit array‐compression matrices with low loss.Keywords
Funding Information
- National Institutes of Health (U01EB025162, R01EB016695)
This publication has 29 references indexed in Scilit:
- Experimental implementation of array‐compressed parallel transmission at 7 teslaMagnetic Resonance in Medicine, 2016
- Array‐compressed parallel transmit pulse designMagnetic Resonance in Medicine, 2015
- Robust time-shifted spoke pulse design in the presence of large B0 variations with simultaneous reduction of through-plane dephasing, B1+ effects, and the specific absorption rate using parallel transmissionMagnetic Resonance in Medicine, 2015
- General design approach and practical realization of decoupling matrices for parallel transmission coilsMagnetic Resonance in Medicine, 2015
- Impact of number of channels on RF shimming at 3TMagnetic Resonance Materials in Physics, Biology and Medicine, 2013
- Detection of RF unsafe devices using a parallel transmission MR systemMagnetic Resonance in Medicine, 2012
- Microstrip Butler matrix design and realization for 7 T MRIMagnetic Resonance in Medicine, 2011
- Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitationsMagnetic Resonance in Medicine, 2009
- Exploring the limits of RF shimming for high‐field MRI of the human headMagnetic Resonance in Medicine, 2006
- Effects of static and radiofrequency magnetic field inhomogeneity in ultra-high field magnetic resonance imagingMagnetic Resonance Imaging, 2006