QWQiang Wang

Qiang Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qiang Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Time-Dependent Changes of Automated 3D Breast Ultrasound-Visible Mesh Implants in Patients

    by Minqin Xia, Jun Wu, Guangqian Yan, Quanwei Cai, Qiang Wang, Zhaomin Zhang

    The shrinkage and deformation of the mesh can be the causes of hernia recurrence and other related complications. Accurate visualization of the mesh and its position would greatly aid in assessing mesh shrinkage, evaluating the risk of hernia recurrence, and setting the preoperative plan for repair. The purpose of this study is to noninvasively describe and quantify the shrinkage, movement, and centroid position of lightweight mesh implants using Automated 3D breast ultrasound (ABUS) through in vivo and vitro studies. In vitro study, ABUS can visualize spatial morphological changes in meshes, which solves the problem of difficult imaging detection of lightweight mesh. The vitro study showed that the maximum deviation between the quantification based on ABUS and the actual mesh size was 3.5%. In vivo study, ABUS not only allows for imaging conventional lightweight meshes but also for assessing time-dependent changes in lightweight mesh implants. The average shrinkage from day 5 to day 90 after surgery was 20.2%, while the average deviation in centroid position was 0.23cm in the vivo study. The problem of postoperative evaluation of lightweight mesh imaging can be effectively addressed by time-dependent assessing and analysis of mesh implants in patients.

  • Open Access

    Does the Fixation Device Affect the Fixation Strength of the Tack in Laparoscopic Incisional Hernia Repair?

    by Zhaomin Zhang, Jun Wu, Guangqian Yan, Quanwei Cai, Qiang Wang, Minqin Xia

    Background: In laparoscopic ventral hernia repair (LVHR), the fixation strength of the tack plays a crucial role, but there is a lack of clarity in terms of the role of the fixation devices on the tack. Our purpose was to investigate whether fixation devices affect the fixation strength of tacks. Further, we compare four different fixation devices, including the comparison of firing model, the comparison of shaft design, and the comparison of mechanical properties. Methods: The porcine abdominal wall was used as the experimental material to test the immediate fixation strength of four different fixation devices and 26 tests were performed on each fixation device. During the experiments, the mechanical performance indicators such as fixation strength, fluency, and accuracy of each fixation device were recorded and evaluated. Results: The fixation strengths of the Securestrap™ (ST), ReliaTack™ (RT), AbsorbaTack™ (AT), and SorbaFix™ (SF) were 20.65±4.73N, 10.34±1.62N, 14.70±2.51N, and 12.07±1.94N respectively. The ST device had the best fixation strength (RT, p<0.001; AT, p=0.003; SF, p<0.001). When the fixation device is not used (8.21±1.33N, p<0.001), the fixation strength of the ST device is significantly lower than that when the fixation device is used (20.65±4.73N). In the study of firing mode, compared with the fixation strength of both devices, AT and SF, ST device had significantly greater fixation strength (p=0.003, p<0.001 for AT and SF, respectively). The fixation strength of the non-articulated devices AT and SF was significantly higher than that of the articulated device RT (p=0.002, p=0.016 for AT and SF respectively). The differences were statistically significant. Conclusion: The fixation device allows the tack to exhibit better fixation strength in laparoscopic surgery. Further, we found that the ejection of firing mode achieves better fixation strength. In contrast, for articulated devices, the fixation strength was lower for articulated devices than for non-articulated devices, which may be because the articulated shaft was not ergonomic and hindered the transfer of force.

  • Open Access

    Three-Dimensional Reconstruction and Hemodynamic Analysis of Varicose Veins in Lower Extremities Based on ABUS Image

    by Quanwei Cai, Jun Wu, Rong Wang, Qiang Wang, Zhaomin Zhang, Minqin Xia

    Varicose veins in the lower extremities are enlarged and tortuous veins in the lower extremities and are a common surgical condition, affecting people over a wide age range. Venous tortuosity caused by varicose veins in lower extremities would alter the local wall shear stress (WSS) and may become a risk factor for venous thrombosis. In this study, a realistic model of lower limb veins was reconstructed based on denoised and enhanced ABUS images. Mimics Research 21.0 and Geomagic Wrap 2017 were used to perform a 3D reconstruction of the Preprocessed images. The time-averaged WSS (TAWSS), the oscillatory shear index (OSI), the transverse WSS (transWSS), and the relative residence time (RRT) of the reconstructed 3D model were investigated in Ansys Fluent 2021R1 (Ansys Inc.) using computational fluid dynamics methods(CFD). We relate the centerline radius (CLR) of the morphological parameters to the above four parameters. From the results, it is clear that CLR has a great impact on the distributions of the WSS-derived parameters. In regions with smaller CLR, low TAWSS, and high OSI abnormal regions appear in the inner wall of the curved segment. It is also evident in the RRT plots that flow disturbances are seen in small CLR region. Compared with OSI and TAWSS, transWSS is more sensitive to abnormal regions. TransWSS has basically the same distribution as RRT distribution. The results showed that regions accompanied by small CLR would lead to the formation of abnormal MASS regions at the bend sections and provide these regions with favorable conditions for the onset and/or progression of venous thrombosis. It could help advance the use and promotion of hemodynamics in the clinical setting through this analysis process. Due to the limitations of ultrasound technology, in some cases the ultrasound image may not directly reveal the lesion, but the presence and location of the lesion can be determined by haemodynamics. The diagnostic method proposed in this paper has great potential in the diagnosis of varicose veins in the lower limbs. It can help the practitioner to better understand the patient's condition.

  • ETC-Oriented Efficient and Secure Blockchain: Credit-Based Mechanism and Evidence Framework for Vehicle Management

    by Jishu Wang, Rui Zhu, Tong Li, Fengsen Gao, Qiang Wang, Qiang Xiao

    An electronic toll collection (ETC) system is one of the most important parts of an intelligent transportation system (ITS), but existing ETC systems are not efficient and have vehicle fee evasion complications. Owing to the traceability and tamper resistance of a blockchain, the combination of a blockchain and ETC system is a feasible way to solve the above problems. However, traditional blockchain (e.g., Bitcoin and Ethereum) has high power consumption and low efficiency. Hence, it cannot be used in ETC systems with high throughput and is not suitable for power-constrained Internet of Things (IoT) devices. In this study, therefore, we propose a blockchain architecture for the ETC system. To curb vehicle fee evasion behavior, thereby reducing the economic loss caused, we propose a vehicle behavior management mechanism based on credit value. Furthermore, to reduce the burden of storage and build a chain of evidence for auditing purposes, we propose an evidence chain framework. To protect the data security in the transaction process, we designed a data protection method to encrypt the transaction data. Additionally, this system is based on an open-source alliance blockchain framework called Hyperledger Fabric, which is more in line with the current application scenarios of ETC systems. We implemented the system on a Raspberry Pi and carried out simulations. The comprehensive evaluation results and analysis show that the system effectively reduces the number of illegal acts, completes the evidence inspection, and improves the security of the data.