Zhaomin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhaomin Zhang has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Jun Zhou
University of Electronic Science and Technology of China
4 shared publications - Liang Chang
University of Electronic Science and Technology of China
4 shared publications - Jun Wu
School of Information Science & Engineering, Yunnan University, China
3 shared publications Minqin Xia
School of Information Science & Engineering, Yunnan University, China
3 shared publications- Qiang Wang
School of Information Science & Engineering, Yunnan University, China
3 shared publications Quanwei Cai
School of Information Science & Engineering, Yunnan University, China
3 shared publications
Latest Publications
- 12 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 61 (2) , 791-807
FSNAP: An Ultra-Energy-Efficient Reconfigurable Few-Spikes-Neuron-Based SNN Processor Supporting Unified On-Chip Learning and Adaptive Time-Window Tuning
Spiking neural network (SNN) processors have attracted significant attention as energy-efficient alternatives to artificial neural network (ANN) processors due to their event-driven and sparse computing properties. However, existing SNN processors primarily rely on leaky-integrate-and-fire (LIF) neurons, which require large time-windows (TWs) and a substantial number of spikes to achieve high accuracy. This results in excessive energy consumption and high latency. Furthermore, most SNN processors either support spike-based backpropagation (BP) learning or ANN-to-SNN conversion-based learning, limiting their adaptability across diverse applications. Additionally, the use of fixed-size TWs leads to inefficient resource utilization and poor adaptability to dynamic input characteristics. To address these challenges, this work proposes FSNAP, an energy-efficient SNN processor that leverages the recently introduced few-spikes-neuron (FSN) model. Unlike conventional LIF neurons, FSNs utilize an optimized spike encoding and decoding scheme that enables high computational efficiency with significantly fewer spikes and a shorter time window. The proposed processor has the following contributions: 1) a reconfigurable FSN-based SNN inference and learning architecture with time-skipped spike accumulation and parallel spike generation, which achieves low-latency, high-efficiency computation; 2) a unified on-chip learning architecture supporting the proposed low-complexity FSN-hybrid learning, FSN-BP learning, and ANN-to-FSN-SNN conversion based (FSN-conversion) learning, which enhances accuracy and flexibility across various applications; and 3) an accuracy-driven adaptive TW tuning technique that dynamically adjusts TW sizes to optimize energy consumption and latency while maintaining high accuracy. Fabricated in a 55-nm CMOS process, FSNAP achieves substantial improvements over state-of-the-art SNN designs on six different tasks. On the IMAGE task, it demonstrates $2.24{\times }$ to $172.8{\times }$ higher energy efficiency when scaled to the same process node and operating voltage, and $3.40{\times }$ to $1616.4{\times }$ speedup when scaled to the same operating frequency, all while maintaining high accuracy.
- 12 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 61 (2) , 791-807
FSNAP: An Ultra-Energy-Efficient Reconfigurable Few-Spikes-Neuron-Based SNN Processor Supporting Unified On-Chip Learning and Adaptive Time-Window Tuning
Spiking neural network (SNN) processors have attracted significant attention as energy-efficient alternatives to artificial neural network (ANN) processors due to their event-driven and sparse computing properties. However, existing SNN processors primarily rely on leaky-integrate-and-fire (LIF) neurons, which require large time-windows (TWs) and a substantial number of spikes to achieve high accuracy. This results in excessive energy consumption and high latency. Furthermore, most SNN processors either support spike-based backpropagation (BP) learning or ANN-to-SNN conversion-based learning, limiting their adaptability across diverse applications. Additionally, the use of fixed-size TWs leads to inefficient resource utilization and poor adaptability to dynamic input characteristics. To address these challenges, this work proposes FSNAP, an energy-efficient SNN processor that leverages the recently introduced few-spikes-neuron (FSN) model. Unlike conventional LIF neurons, FSNs utilize an optimized spike encoding and decoding scheme that enables high computational efficiency with significantly fewer spikes and a shorter time window. The proposed processor has the following contributions: 1) a reconfigurable FSN-based SNN inference and learning architecture with time-skipped spike accumulation and parallel spike generation, which achieves low-latency, high-efficiency computation; 2) a unified on-chip learning architecture supporting the proposed low-complexity FSN-hybrid learning, FSN-BP learning, and ANN-to-FSN-SNN conversion based (FSN-conversion) learning, which enhances accuracy and flexibility across various applications; and 3) an accuracy-driven adaptive TW tuning technique that dynamically adjusts TW sizes to optimize energy consumption and latency while maintaining high accuracy. Fabricated in a 55-nm CMOS process, FSNAP achieves substantial improvements over state-of-the-art SNN designs on six different tasks. On the IMAGE task, it demonstrates $2.24{\times }$ to $172.8{\times }$ higher energy efficiency when scaled to the same process node and operating voltage, and $3.40{\times }$ to $1616.4{\times }$ speedup when scaled to the same operating frequency, all while maintaining high accuracy.
- 17 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60 (10) , 3762-3778
A High-Accuracy and Ultra-Energy-Efficient Cardiac Arrhythmia Classification Processor for Wearable Intelligent ECG Monitoring
Wearable intelligent electrocardiography (ECG) sensors with integrated cardiac arrhythmia classification processors have been used to detect and classify arrhythmia, alerting users to potential cardiac diseases. While state-of-the-art arrhythmia classification processors employ neural networks (NNs), the high computational complexity of NNs results in significant energy consumption, limiting the model size and classification performance of NNs. Additionally, inter-patient variation in ECG can lead to accuracy degradation when applying a trained NN to patients whose ECG features differ from those in the training dataset. In this work, we propose an ultra-energy-efficient cardiac arrhythmia classification processor incorporating three key technologies: 1) heartbeat difference-based classification to improve accuracy under inter-patient variation and reduce energy consumption; 2) event-driven NN computation with shared feature extraction to reduce energy consumption; and 3) an adaptive NN wake-up technique to reduce energy consumption while maintaining accuracy. The design was fabricated using 55-nm CMOS process technology and evaluated using the MIT-BIH arrhythmia dataset. For arrhythmia classification, it demonstrates an energy consumption of $0.09~{\mu }$ J per classification with 98.7%/96.6% accuracy for intra-patient and inter-patient testing, respectively.
- 17 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60 (10) , 3762-3778
A High-Accuracy and Ultra-Energy-Efficient Cardiac Arrhythmia Classification Processor for Wearable Intelligent ECG Monitoring
Wearable intelligent electrocardiography (ECG) sensors with integrated cardiac arrhythmia classification processors have been used to detect and classify arrhythmia, alerting users to potential cardiac diseases. While state-of-the-art arrhythmia classification processors employ neural networks (NNs), the high computational complexity of NNs results in significant energy consumption, limiting the model size and classification performance of NNs. Additionally, inter-patient variation in ECG can lead to accuracy degradation when applying a trained NN to patients whose ECG features differ from those in the training dataset. In this work, we propose an ultra-energy-efficient cardiac arrhythmia classification processor incorporating three key technologies: 1) heartbeat difference-based classification to improve accuracy under inter-patient variation and reduce energy consumption; 2) event-driven NN computation with shared feature extraction to reduce energy consumption; and 3) an adaptive NN wake-up technique to reduce energy consumption while maintaining accuracy. The design was fabricated using 55-nm CMOS process technology and evaluated using the MIT-BIH arrhythmia dataset. For arrhythmia classification, it demonstrates an energy consumption of $0.09~{\mu }$ J per classification with 98.7%/96.6% accuracy for intra-patient and inter-patient testing, respectively.
- 23 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (5) , 832-841
An Ultra-Energy-Efficient and High Accuracy ECG Classification Processor With SNN Inference Assisted by On-Chip ANN Learning
The ECG classification processor is a key component in wearable intelligent ECG monitoring devices which monitor the ECG signals in real time and detect the abnormality automatically. The state-of-the-art ECG classification processors for wearable intelligent ECG monitoring devices are faced with two challenges, including ultra-low energy consumption demand and high classification accuracy demand against patient-to-patient variability. To address the above two challenges, in this work, an ultra-energy-efficient ECG classification processor with high classification accuracy is proposed. Several design techniques have been proposed, including a reconfigurable SNN/ANN inference architecture for reducing energy consumption while maintaining classification accuracy, a reconfigurable on-chip learning architecture for improving the classification accuracy against patent-to-patient variability, and a dual-purpose binary encoding scheme of ECG heartbeats for further reducing the energy consumption. Fabricated with a 28nm CMOS technology, the proposed design consumes extremely low classification energy (0.3μJ) while achieving high classification accuracy (97.36%) against patient-to-patient variability, outperforming several state-of-the-art designs.
- 23 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 16 (5) , 832-841
An Ultra-Energy-Efficient and High Accuracy ECG Classification Processor With SNN Inference Assisted by On-Chip ANN Learning
The ECG classification processor is a key component in wearable intelligent ECG monitoring devices which monitor the ECG signals in real time and detect the abnormality automatically. The state-of-the-art ECG classification processors for wearable intelligent ECG monitoring devices are faced with two challenges, including ultra-low energy consumption demand and high classification accuracy demand against patient-to-patient variability. To address the above two challenges, in this work, an ultra-energy-efficient ECG classification processor with high classification accuracy is proposed. Several design techniques have been proposed, including a reconfigurable SNN/ANN inference architecture for reducing energy consumption while maintaining classification accuracy, a reconfigurable on-chip learning architecture for improving the classification accuracy against patent-to-patient variability, and a dual-purpose binary encoding scheme of ECG heartbeats for further reducing the energy consumption. Fabricated with a 28nm CMOS technology, the proposed design consumes extremely low classification energy (0.3μJ) while achieving high classification accuracy (97.36%) against patient-to-patient variability, outperforming several state-of-the-art designs.
- Open Access
- 27 May 2022
- Published by Association for Computing Machinery (ACM)
- Vol. 13, 34-40
Time-Dependent Changes of Automated 3D Breast Ultrasound-Visible Mesh Implants in Patients
The shrinkage and deformation of the mesh can be the causes of hernia recurrence and other related complications. Accurate visualization of the mesh and its position would greatly aid in assessing mesh shrinkage, evaluating the risk of hernia recurrence, and setting the preoperative plan for repair. The purpose of this study is to noninvasively describe and quantify the shrinkage, movement, and centroid position of lightweight mesh implants using Automated 3D breast ultrasound (ABUS) through in vivo and vitro studies. In vitro study, ABUS can visualize spatial morphological changes in meshes, which solves the problem of difficult imaging detection of lightweight mesh. The vitro study showed that the maximum deviation between the quantification based on ABUS and the actual mesh size was 3.5%. In vivo study, ABUS not only allows for imaging conventional lightweight meshes but also for assessing time-dependent changes in lightweight mesh implants. The average shrinkage from day 5 to day 90 after surgery was 20.2%, while the average deviation in centroid position was 0.23cm in the vivo study. The problem of postoperative evaluation of lightweight mesh imaging can be effectively addressed by time-dependent assessing and analysis of mesh implants in patients.
- 27 May 2022
- Published by Association for Computing Machinery (ACM)
- Vol. 13, 34-40
Open AccessTime-Dependent Changes of Automated 3D Breast Ultrasound-Visible Mesh Implants in Patients
The shrinkage and deformation of the mesh can be the causes of hernia recurrence and other related complications. Accurate visualization of the mesh and its position would greatly aid in assessing mesh shrinkage, evaluating the risk of hernia recurrence, and setting the preoperative plan for repair. The purpose of this study is to noninvasively describe and quantify the shrinkage, movement, and centroid position of lightweight mesh implants using Automated 3D breast ultrasound (ABUS) through in vivo and vitro studies. In vitro study, ABUS can visualize spatial morphological changes in meshes, which solves the problem of difficult imaging detection of lightweight mesh. The vitro study showed that the maximum deviation between the quantification based on ABUS and the actual mesh size was 3.5%. In vivo study, ABUS not only allows for imaging conventional lightweight meshes but also for assessing time-dependent changes in lightweight mesh implants. The average shrinkage from day 5 to day 90 after surgery was 20.2%, while the average deviation in centroid position was 0.23cm in the vivo study. The problem of postoperative evaluation of lightweight mesh imaging can be effectively addressed by time-dependent assessing and analysis of mesh implants in patients.
- Open Access
- 27 May 2022
- Published by Association for Computing Machinery (ACM)
- Vol. 26, 184-190
Does the Fixation Device Affect the Fixation Strength of the Tack in Laparoscopic Incisional Hernia Repair?
Background: In laparoscopic ventral hernia repair (LVHR), the fixation strength of the tack plays a crucial role, but there is a lack of clarity in terms of the role of the fixation devices on the tack. Our purpose was to investigate whether fixation devices affect the fixation strength of tacks. Further, we compare four different fixation devices, including the comparison of firing model, the comparison of shaft design, and the comparison of mechanical properties. Methods: The porcine abdominal wall was used as the experimental material to test the immediate fixation strength of four different fixation devices and 26 tests were performed on each fixation device. During the experiments, the mechanical performance indicators such as fixation strength, fluency, and accuracy of each fixation device were recorded and evaluated. Results: The fixation strengths of the Securestrap™ (ST), ReliaTack™ (RT), AbsorbaTack™ (AT), and SorbaFix™ (SF) were 20.65±4.73N, 10.34±1.62N, 14.70±2.51N, and 12.07±1.94N respectively. The ST device had the best fixation strength (RT, p<0.001; AT, p=0.003; SF, p<0.001). When the fixation device is not used (8.21±1.33N, p<0.001), the fixation strength of the ST device is significantly lower than that when the fixation device is used (20.65±4.73N). In the study of firing mode, compared with the fixation strength of both devices, AT and SF, ST device had significantly greater fixation strength (p=0.003, p<0.001 for AT and SF, respectively). The fixation strength of the non-articulated devices AT and SF was significantly higher than that of the articulated device RT (p=0.002, p=0.016 for AT and SF respectively). The differences were statistically significant. Conclusion: The fixation device allows the tack to exhibit better fixation strength in laparoscopic surgery. Further, we found that the ejection of firing mode achieves better fixation strength. In contrast, for articulated devices, the fixation strength was lower for articulated devices than for non-articulated devices, which may be because the articulated shaft was not ergonomic and hindered the transfer of force.
- 27 May 2022
- Published by Association for Computing Machinery (ACM)
- Vol. 26, 184-190
Open AccessDoes the Fixation Device Affect the Fixation Strength of the Tack in Laparoscopic Incisional Hernia Repair?
Background: In laparoscopic ventral hernia repair (LVHR), the fixation strength of the tack plays a crucial role, but there is a lack of clarity in terms of the role of the fixation devices on the tack. Our purpose was to investigate whether fixation devices affect the fixation strength of tacks. Further, we compare four different fixation devices, including the comparison of firing model, the comparison of shaft design, and the comparison of mechanical properties. Methods: The porcine abdominal wall was used as the experimental material to test the immediate fixation strength of four different fixation devices and 26 tests were performed on each fixation device. During the experiments, the mechanical performance indicators such as fixation strength, fluency, and accuracy of each fixation device were recorded and evaluated. Results: The fixation strengths of the Securestrap™ (ST), ReliaTack™ (RT), AbsorbaTack™ (AT), and SorbaFix™ (SF) were 20.65±4.73N, 10.34±1.62N, 14.70±2.51N, and 12.07±1.94N respectively. The ST device had the best fixation strength (RT, p<0.001; AT, p=0.003; SF, p<0.001). When the fixation device is not used (8.21±1.33N, p<0.001), the fixation strength of the ST device is significantly lower than that when the fixation device is used (20.65±4.73N). In the study of firing mode, compared with the fixation strength of both devices, AT and SF, ST device had significantly greater fixation strength (p=0.003, p<0.001 for AT and SF, respectively). The fixation strength of the non-articulated devices AT and SF was significantly higher than that of the articulated device RT (p=0.002, p=0.016 for AT and SF respectively). The differences were statistically significant. Conclusion: The fixation device allows the tack to exhibit better fixation strength in laparoscopic surgery. Further, we found that the ejection of firing mode achieves better fixation strength. In contrast, for articulated devices, the fixation strength was lower for articulated devices than for non-articulated devices, which may be because the articulated shaft was not ergonomic and hindered the transfer of force.
- Open Access
- 27 May 2022
- Published by Association for Computing Machinery (ACM)
- Vol. 27, 7-14
Three-Dimensional Reconstruction and Hemodynamic Analysis of Varicose Veins in Lower Extremities Based on ABUS Image
Varicose veins in the lower extremities are enlarged and tortuous veins in the lower extremities and are a common surgical condition, affecting people over a wide age range. Venous tortuosity caused by varicose veins in lower extremities would alter the local wall shear stress (WSS) and may become a risk factor for venous thrombosis. In this study, a realistic model of lower limb veins was reconstructed based on denoised and enhanced ABUS images. Mimics Research 21.0 and Geomagic Wrap 2017 were used to perform a 3D reconstruction of the Preprocessed images. The time-averaged WSS (TAWSS), the oscillatory shear index (OSI), the transverse WSS (transWSS), and the relative residence time (RRT) of the reconstructed 3D model were investigated in Ansys Fluent 2021R1 (Ansys Inc.) using computational fluid dynamics methods(CFD). We relate the centerline radius (CLR) of the morphological parameters to the above four parameters. From the results, it is clear that CLR has a great impact on the distributions of the WSS-derived parameters. In regions with smaller CLR, low TAWSS, and high OSI abnormal regions appear in the inner wall of the curved segment. It is also evident in the RRT plots that flow disturbances are seen in small CLR region. Compared with OSI and TAWSS, transWSS is more sensitive to abnormal regions. TransWSS has basically the same distribution as RRT distribution. The results showed that regions accompanied by small CLR would lead to the formation of abnormal MASS regions at the bend sections and provide these regions with favorable conditions for the onset and/or progression of venous thrombosis. It could help advance the use and promotion of hemodynamics in the clinical setting through this analysis process. Due to the limitations of ultrasound technology, in some cases the ultrasound image may not directly reveal the lesion, but the presence and location of the lesion can be determined by haemodynamics. The diagnostic method proposed in this paper has great potential in the diagnosis of varicose veins in the lower limbs. It can help the practitioner to better understand the patient's condition.
- 27 May 2022
- Published by Association for Computing Machinery (ACM)
- Vol. 27, 7-14
Open AccessThree-Dimensional Reconstruction and Hemodynamic Analysis of Varicose Veins in Lower Extremities Based on ABUS Image
Varicose veins in the lower extremities are enlarged and tortuous veins in the lower extremities and are a common surgical condition, affecting people over a wide age range. Venous tortuosity caused by varicose veins in lower extremities would alter the local wall shear stress (WSS) and may become a risk factor for venous thrombosis. In this study, a realistic model of lower limb veins was reconstructed based on denoised and enhanced ABUS images. Mimics Research 21.0 and Geomagic Wrap 2017 were used to perform a 3D reconstruction of the Preprocessed images. The time-averaged WSS (TAWSS), the oscillatory shear index (OSI), the transverse WSS (transWSS), and the relative residence time (RRT) of the reconstructed 3D model were investigated in Ansys Fluent 2021R1 (Ansys Inc.) using computational fluid dynamics methods(CFD). We relate the centerline radius (CLR) of the morphological parameters to the above four parameters. From the results, it is clear that CLR has a great impact on the distributions of the WSS-derived parameters. In regions with smaller CLR, low TAWSS, and high OSI abnormal regions appear in the inner wall of the curved segment. It is also evident in the RRT plots that flow disturbances are seen in small CLR region. Compared with OSI and TAWSS, transWSS is more sensitive to abnormal regions. TransWSS has basically the same distribution as RRT distribution. The results showed that regions accompanied by small CLR would lead to the formation of abnormal MASS regions at the bend sections and provide these regions with favorable conditions for the onset and/or progression of venous thrombosis. It could help advance the use and promotion of hemodynamics in the clinical setting through this analysis process. Due to the limitations of ultrasound technology, in some cases the ultrasound image may not directly reveal the lesion, but the presence and location of the lesion can be determined by haemodynamics. The diagnostic method proposed in this paper has great potential in the diagnosis of varicose veins in the lower limbs. It can help the practitioner to better understand the patient's condition.
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 68 (4) , 1543-1552
A Fast and Energy-Efficient SNN Processor With Adaptive Clock/Event-Driven Computation Scheme and Online Learning
In the recent years, the spiking neural network (SNN) has attracted increasing attention due to its low energy consumption and online learning potential. However, the design of SNN processor has not been thoroughly investigated in the past, resulting in limited performance and energy consumption. In this work, a fast and energy-efficient SNN processor with adaptive clock/event-driven computation scheme and online learning capability has been proposed. Several techniques have been proposed to reduce the computation time and energy consumption, including Adaptive Clock- and Event-Driven Computing Scheme, Neighboring PE Borrowing Technique, Compressed Spike Routing Technique and Reconfigurable PE for Inference and Learning. Implemented on a Virtex-7 FPGA, the proposed design achieves computation time of 3.15 ms/image, inference energy consumption of$0.028~\mu $ J/synapse/image and online learning energy consumption of$0.297~\mu $ J/synapse/image for the MNIST 10-class dataset, which outperform several state-of-the-art SNN processors. The proposed SNN processor is suitable for real-time and energy-constrained applications.- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 68 (4) , 1543-1552
A Fast and Energy-Efficient SNN Processor With Adaptive Clock/Event-Driven Computation Scheme and Online Learning
In the recent years, the spiking neural network (SNN) has attracted increasing attention due to its low energy consumption and online learning potential. However, the design of SNN processor has not been thoroughly investigated in the past, resulting in limited performance and energy consumption. In this work, a fast and energy-efficient SNN processor with adaptive clock/event-driven computation scheme and online learning capability has been proposed. Several techniques have been proposed to reduce the computation time and energy consumption, including Adaptive Clock- and Event-Driven Computing Scheme, Neighboring PE Borrowing Technique, Compressed Spike Routing Technique and Reconfigurable PE for Inference and Learning. Implemented on a Virtex-7 FPGA, the proposed design achieves computation time of 3.15 ms/image, inference energy consumption of$0.028~\mu $ J/synapse/image and online learning energy consumption of$0.297~\mu $ J/synapse/image for the MNIST 10-class dataset, which outperform several state-of-the-art SNN processors. The proposed SNN processor is suitable for real-time and energy-constrained applications.- 1 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 122-127
Carrier phase estimation schemes with bit-error-rate independent and modulation format transparency
Low complexity carrier phase estimation (CPE) with bit-error-rate independent and modulation format transparency is very important for coherent optical communication receiver, and is still a challenge task. We propose a series of schemes of good performance and low complexity CPE, including an optical pilot-tone-added (PA) method and a crossed constellation transformation (CCT) algorithm, which are proved to be linewidth tolerant, bit-error-rate independent, modulation format transparent, and low complexity. We introduce an optical pilot-tone-added CPE scheme for a dual-carrier Nyquist m-QAM system. We also present a multi-stage CPE scheme based on CCT for either the square-frame m-QAM like 64QAM or the non-square-frame m-QAM like 32-QAM and 128-QAM.
- 1 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 122-127
Carrier phase estimation schemes with bit-error-rate independent and modulation format transparency
Low complexity carrier phase estimation (CPE) with bit-error-rate independent and modulation format transparency is very important for coherent optical communication receiver, and is still a challenge task. We propose a series of schemes of good performance and low complexity CPE, including an optical pilot-tone-added (PA) method and a crossed constellation transformation (CCT) algorithm, which are proved to be linewidth tolerant, bit-error-rate independent, modulation format transparent, and low complexity. We introduce an optical pilot-tone-added CPE scheme for a dual-carrier Nyquist m-QAM system. We also present a multi-stage CPE scheme based on CCT for either the square-frame m-QAM like 64QAM or the non-square-frame m-QAM like 32-QAM and 128-QAM.