DGDi Gong

Di Gong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Di Gong has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • In situ decoupling of pump-induced spin polarization noise in atomic spin sensors

    by Dinghui Gong, Xiaofei Huang, Di Gong, Yang Rui, Chang Liu, Xing Heng, Kai Wei, Wei Quan

    In atomic spin sensors based on optical pumping, pump beam instabilities can drive atomic spin polarization fluctuations, referred to here as pump-induced spin polarization noise, which may limit sensitivity and long-term stability. Because the local pump field inside the cell can differ from that inferred from external optical diagnostics, it remains difficult to directly quantify the actual in situ spin polarization noise and to evaluate and suppress its contribution to the sensor noise floor. Here, we propose an in situ decoupling method based on spin dynamics, in which a large longitudinal detuning field suppresses magnetic field and rotation responses, while a transverse projection field converts pump-induced fluctuations in longitudinal spin polarization into a measurable transverse spin signal. Demonstrated in a K-Rb-21Ne spin exchange relaxation free (SERF) comagnetometer, the proposed method suppresses the magnetic-field response by approximately 180-fold and enhances the pump-power-noise response by approximately 380-fold, thereby enabling effective separation and evaluation of pump-induced spin polarization noise. The method employs the atomic ensemble as an in situ probe of the spin dynamic response to the local pump optical field. It enables quantitative identification of pump fluctuation associated noise and direct evaluation of optical field stability under actual operating conditions, thereby providing an experimental basis for optical field stabilization and noise suppression assessment in SERF comagnetometers and related alkali atomic spin sensors.

  • Non-perturbative suppression of spin polarization noise in SERF comagnetometers

    by Dinghui Gong, Di Gong, Xiaofei Huang, Yijin Liu, Saixin Zhou, Kai Wei, Wei Quan

  • Identification and Analysis of Thermal–Magnetic Coupling Noise in SERF Comagnetometer

    by Xiaofei Huang, Xing Heng, Di Gong, Haipeng Zhu, Dinghui Gong, Yijin Liu, Wei Quan, Kai Wei

    The ultrahigh sensitivity of spin-exchange relaxation-free (SERF) magnetometers and comagnetometers plays a crucial role in tests of fundamental physics, biomagnetic measurement, and quantum navigation. The high atomic number density is essential for achieving the SERF regime, making the heating system an indispensable component. However, thermal-magnetic coupling noise generated by the heating system represents a primary source of perturbation for precision measurement based on thermal atomic ensemble. We identify the main sources of thermal-magnetic coupling noise based on a K-Rb-21Ne SERF comagnetometer. By optimizing the operating mode of the heating system, the low-frequency noise at 0.5 Hz is improved by approximately one order of magnitude, thereby enhancing the low-frequency sensitivity of the SERF comagnetometer. Our research advances the long-term stability of atomic sensors and supports their application in probing new physics beyond the Standard Model in the low-energy regime.

  • In Situ Suppression of Thermal–Magnetic Coupling Noise in Atomic Sensors

    by Yijin Liu, Bin Wang, Di Gong, Weiyi Wang, Dinghui Gong, Xiaofei Huang, Kai Wei

    Spin-based sensors, such as magnetometers and comagnetometers, require precise control of thermal conditions and magnetic fields to achieve optimal performance. Thermal-magnetic coupling noise, induced by heating systems, is one of the limiting factors for sensitivity improvement. In this paper, the in-situ suppression method is proposed to eliminate thermal-magnetic coupling noise by employing the double-layer heater with dynamically adjustable current ratios. The in-situ method is verified across two distinct systems, including commercial magnetometer and the self-developed comagnetometer. For magnetometer system, the heating-induced magnetic interferences of the double-layer heater along three directions have been decreased over 2 orders compared to a conventional heater. Similarly, the total magnetic flux density has been suppressed by more than 78%. Furthermore, the thermal-magnetic coupling noise in K-Rb-21Ne comagnetometer equipped with the double-layer heater is in-situ suppressed to 6.54×10-9 °/s/Hz1/2 (0.01 fT/ Hz1/2) at 1 Hz, achieving a noise reduction of 22 dB compared to ex-situ method and 24 dB suppression relative to a conventional heater. Besides, the double-layer heater ensures a uniform and stable thermal field across the vapor cell, with a temperature variance less than 0.65 °C and a temperature fluctuation 65% lower than a conventional heater. This work advances ultra-sensitive quantum sensors by providing an effective method to in-situ suppress thermal-magnetic coupling noise.

  • Open Access

    Constraints on Axion Mediated Dipole-Dipole Interactions

    by Zitong Xu, Xing Heng, Guoqing Tian, Di Gong, Lei Cong, Wei Ji, Dmitry Budker, Kai Wei

    The search for axions sits at the intersection of solving critical problems in fundamental physics, including the strong C P problem in QCD, uncovering the nature of dark matter, and understanding the origin of the Universe’s matter-antimatter asymmetry. The measurement of axion mediated spin-dependent interactions offers a powerful approach for axion detection. However, it has long been restricted to regions outside the “axion window” due to a significant trade-off: the need to effectively suppress the magnetic leakage from highly polarized spin sources while simultaneously detecting subfemtotesla level exotic physics signals at sub-decimeter-scale distances. In this work, we report new experimental results on axion mediated exotic spin-spin interactions using an iron-shielded SmCo 5 spin source in combination with a specially designed self-compensation comagnetometer. Employing a composite shielding structure, we achieved a suppression of the magnetic field by up to 10 11 . This enabled us to establish new constraints on the coupling between electrons and neutrons, improving previous experimental limits by up to 10 000 times within the axion window. Furthermore, we also set the strongest constraints on the coupling between electrons and protons. The proposed method holds substantial potential not only for advancing the search for new physics beyond the standard model but also for enabling transformative applications in biological and chemical research.


  • Decoupling Method of Triaxial Magnetic Field Compensation and Multiparameter Measurement in Comagnetometers

    by Dinghui Gong, Zitong Xu, Xiaofei Huang, Di Gong, Chang Liu, Xing Heng, Fan Wang, Weiyi Wang, Kai Wei, Wei Quan

    Spin exchange relaxation free (SERF) comagnetometers possess considerable potential for applications in fundamental physics research and inertial navigation. Operating comagnetometers at the magnetic field compensation point and performing multi-parameter measurement are fundamental to reducing the magnetic noise and maintaining high performance. However, the crosstalk among the triaxial magnetic fields diminishes the effectiveness and accuracy of magnetic field compensation and multi-parameter measurement. To address this limitation, we propose a novel method for in-situ rapid and accurate magnetic field compensation and multi-parameter measurement. The decoupling of the triaxial magnetic fields, achieved experimentally through first-order and second-order approximations based on the modulation dynamics of coupled electronic-nuclear spins, enables the direct determination of the magnetic field compensation point. Additionally, the method facilitates the derivation of both the scale factor and the electronic spin relaxation rate. The proposed method addresses the issue of triaxial magnetic field coupling, enhancing the accuracy and efficiency of magnetic compensation and multi-parameter measurement. The proposed method saves more than 70compared to the non-decoupled method, maintaining magnetic field compensation accuracy within 0.2 nT. It demonstrates promising potential for precise magnetic field manipulation and real-time closed-loop control of comagnetometers.


  • Investigation on the Effects of Microvibration on the Atomic Comagnetometer

    by Chang Liu, Kai Wei, Zitong Xu, Yichao Tian, Chencheng Tang, Di Gong, Xinda Song, Yueyang Zhai

    Precision measurements utilizing atomic spins are widely used in fundamental physics research, inertial sensing, biomagnetism, and the generation of standard quantities. These precision measurements based on quantum sensors have long been disturbed by micro-vibration. In this work, we study the influence of micro-vibration on spin ensembles and perform the experiment on atomic comagnetometer for the first time, which is a powerful tool for search for dark matter and new force, as well as inertial navigation. The model of the effects of micro-vibration on the atomic comagnetometer is established, which considers the transfer characteristics of micro-vibration and the response characteristics of the atomic spin ensembles to the vibration. Moreover, we develop a vibration isolation system, which is a combination of air-floating passive vibration isolators and active feedback systems, to suppress the influence of micro-vibration. Based on the established model and the vibration isolator, we achieve an ultrahigh sensitive comagnetometer, which is among the most sensitive comagnetometer. This work is of wide interest in precision measurement based on quantum sensors and could pave the way for the design of combined vibration isolation systems for such experiments to further improve the sensitivity.


  • Open Access

    Bio-inspired magnetic-driven folded diaphragm for biomimetic robot

    by Dezhao Lin, Fan Yang, Di Gong, Ruihong Li

    Functional soft materials, exhibiting multiple types of deformation, have shown their potential/abilities to achieve complicated biomimetic behaviors (soft robots). Inspired by the locomotion of earthworm, which is conducted through the contraction and stretching between body segments, this study proposes a type of one-piece-mold folded diaphragm, consisting of the structure of body segments with radial magnetization property, to achieve large 3D and bi-directional deformation with inside-volume change capability subjected to the low homogeneous magnetically driving field (40 mT). Moreover, the appearance based on the proposed magnetic-driven folded diaphragm is able to be easily customized to desired ones and then implanted into different untethered soft robotic systems as soft drivers. To verify the above points, we design the diaphragm pump providing unique properties of lightweight, powerful output and rapid response, and the soft robot including the bio-earthworm crawling robot and swimming robot inspired by squid to exhibit the flexible and rapid locomotion excited by single homogeneous magnetic fields.


  • Deformation properties of novel chain-like structural magneto-active elastomers

    by Di Gong, Fan Yang, Wenbo Qian, Chenghong Li, Dezhao Lin, Ruihong Li, Sheng Jia, Yunxiao Chen, Feng Zhao, Hongwei Chen

    Soft Magneto-active Elastomer (MAE) with soft magnetic particles arranged in chains (chain-like structure) can be driven by homogenous magnetic fields, which has great application potential in the area of soft robots. It is important to reveal the relationship between the magneto-actuation characteristics and the arrangement of chain angle, which is one of the essential issues for the practical application of the MAE with chain-like structure. In this study, the kinetic deformation properties of centimeter-scale soft MAE samples with different chain angles subjected to applied homogenous magnetic fields will be investigated based on the designed experimental set-up, and then a mathematical model will be proposed to describe the kinetic deformation properties. The presented research work will provide fundamental investigation on the application of soft robots based on MAE type materials.


  • Shape-programmable magneto-active elastomer composites for curve and biomimetic behavior imitation

    by Di Gong, Fan Yang, Dezhao Lin, Wenbo Qian, Ruihong Li, Chenghong Li, Hongwei Chen, Sheng Jia

    A programming methodology for the fabrication of soft-magnetic-materials based on magneto-active elastomers for curve and biomimetic behaviors imitation.