Yunxing Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yunxing Song has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Liang Li
Huazhong University of Science and Technology
12 shared publications - Qiuliang Wang
Chinese Academy of Sciences
8 shared publications - Hengkang Zheng
Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
7 shared publications - Jianglan Li
Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan, China
6 shared publications Mengyu Liu
Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
4 shared publications- Zhiwen Cheng
Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology, Wuhan, China
4 shared publications
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Design and experimental evaluation of a small-size, high-precision nuclear magnetic resonance probe for enlarged magnetic field measurement region on small-bore magnetic resonance imaging magnets
High-quality magnetic resonance imaging (MRI) relies on accurate magnetic field characterization; however, commercial nuclear magnetic resonance (NMR) magnetic field probes are often limited in boundary-accessible field mapping for bore-constrained magnets. In this study, a miniature free-induction-decay-based NMR magnetic field probe was developed, integrating a solenoid microcoil, a compact tuning/matching network, and a liquid sample unit, with a maximum width of ∼8 mm. Compared with a commercial NMR reference probe, the developed microprobe showed close agreement in single-point validation and yielded a mean absolute deviation of 0.27 μT in axial comparison measurements (corresponding to 0.039 ppm at 7 T), confirming its field-measurement accuracy and spatial tracking capability. Temperature-sensitivity tests over a range of 15–35 °C showed that the repeated-measurement standard deviation remained within 0.019–0.046 ppm, indicating good measurement stability. In wall-adjacent measurements inside a 172 mm-bore magnet, the maximum accessible trajectory diameter increased from 152 to 164 mm, corresponding to a 7.9% improvement in an accessible mapping range. Spherical-surface mapping of a 50 mm diameter spherical volume further yields a mean absolute deviation of 0.143 μT and a Pearson correlation coefficient greater than 0.99. These results demonstrate that the proposed microprobe provides a low-cost, stable, high-precision, and broadly applicable solution for extending accessible magnetic field mapping in bore-constrained MRI magnets.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Design and experimental evaluation of a small-size, high-precision nuclear magnetic resonance probe for enlarged magnetic field measurement region on small-bore magnetic resonance imaging magnets
High-quality magnetic resonance imaging (MRI) relies on accurate magnetic field characterization; however, commercial nuclear magnetic resonance (NMR) magnetic field probes are often limited in boundary-accessible field mapping for bore-constrained magnets. In this study, a miniature free-induction-decay-based NMR magnetic field probe was developed, integrating a solenoid microcoil, a compact tuning/matching network, and a liquid sample unit, with a maximum width of ∼8 mm. Compared with a commercial NMR reference probe, the developed microprobe showed close agreement in single-point validation and yielded a mean absolute deviation of 0.27 μT in axial comparison measurements (corresponding to 0.039 ppm at 7 T), confirming its field-measurement accuracy and spatial tracking capability. Temperature-sensitivity tests over a range of 15–35 °C showed that the repeated-measurement standard deviation remained within 0.019–0.046 ppm, indicating good measurement stability. In wall-adjacent measurements inside a 172 mm-bore magnet, the maximum accessible trajectory diameter increased from 152 to 164 mm, corresponding to a 7.9% improvement in an accessible mapping range. Spherical-surface mapping of a 50 mm diameter spherical volume further yields a mean absolute deviation of 0.143 μT and a Pearson correlation coefficient greater than 0.99. These results demonstrate that the proposed microprobe provides a low-cost, stable, high-precision, and broadly applicable solution for extending accessible magnetic field mapping in bore-constrained MRI magnets.
- 1 October 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (10) , 103003
Review of superconducting vector magnet technology: topology, electromagnetic design, and challenges
Superconducting vector magnets can generate steady, controllable magnetic fields in three-dimensional space and have gradually become an important approach for realising high-field vector magnetic environments in advanced scientific applications. As a key external-field parameter in frontier research areas such as quantum computing, strongly correlated electron systems, topological phases of matter, and spintronic devices, vector magnetic fields are subject to increasingly stringent requirements in terms of field magnitude, directional control accuracy, and operational stability. Compared with sample rotators, permanent-magnet arrays, and pulsed vector magnets, superconducting vector magnets offer significant advantages in high field strength, high field homogeneity, long-term stable operation, and compatibility with cryogenic environments. This paper provides a systematic overview of mainstream approaches to vector magnetic field generation, with a particular focus on superconducting vector magnets. First, the major schemes for generating vector magnetic fields are classified and compared, and their performance limits and applicable scenarios are analysed. Second, the electromagnetic design theories of representative superconducting vector magnet topologies are reviewed. In accordance with the chronological sequence of their development, the core logic and theoretical foundations of each design theory are introduced, the characteristics and performance of typical topologies under each design theory are evaluated, and the evolutionary trends in superconducting vector magnet design theory are summarised. Finally, the key technical challenges facing the future development of superconducting vector magnets are discussed. This paper aims to provide a systematic reference for the design and application of high-performance superconducting vector magnets.
- 1 October 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (10) , 103003
Review of superconducting vector magnet technology: topology, electromagnetic design, and challenges
Superconducting vector magnets can generate steady, controllable magnetic fields in three-dimensional space and have gradually become an important approach for realising high-field vector magnetic environments in advanced scientific applications. As a key external-field parameter in frontier research areas such as quantum computing, strongly correlated electron systems, topological phases of matter, and spintronic devices, vector magnetic fields are subject to increasingly stringent requirements in terms of field magnitude, directional control accuracy, and operational stability. Compared with sample rotators, permanent-magnet arrays, and pulsed vector magnets, superconducting vector magnets offer significant advantages in high field strength, high field homogeneity, long-term stable operation, and compatibility with cryogenic environments. This paper provides a systematic overview of mainstream approaches to vector magnetic field generation, with a particular focus on superconducting vector magnets. First, the major schemes for generating vector magnetic fields are classified and compared, and their performance limits and applicable scenarios are analysed. Second, the electromagnetic design theories of representative superconducting vector magnet topologies are reviewed. In accordance with the chronological sequence of their development, the core logic and theoretical foundations of each design theory are introduced, the characteristics and performance of typical topologies under each design theory are evaluated, and the evolutionary trends in superconducting vector magnet design theory are summarised. Finally, the key technical challenges facing the future development of superconducting vector magnets are discussed. This paper aims to provide a systematic reference for the design and application of high-performance superconducting vector magnets.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-6
Passive Shimming of a 7T Cryogen-Free MRI Superconducting Magnet via Iron Strip Arrangement
The conventional iron matrix shimming method is highly sensitive to the positional variations, especially in small-aperture magnets where limited space imposes significant constraints on feasibility and precision. To address these challenges, this work studied an iron-strip shimming approach following superconducting shimming, replacing the traditional iron matrix scheme for a 7 T/54 mm micro-imaging MRI magnet. A key objective was to realize a 30 mm magnetic field homogenous area, three times larger than that of the typical 10 mm region in common nuclear magnetic resonance (NMR) magnets. To conserve space and leaving enough room for small animal placement, iron strips were positioned around the outer periphery of the gradient assembly, with the iron thickness limited to remain below 0.2 mm, ensuring no interference with gradient assembly installation. This configuration minimized mutual interactions among the iron strips and maximized field homogeneity. Experimental results showed that the peak-peak field homogeneity improved from 11.12 ppm to 4.82 ppm, presenting a 56% enhancement. Additionally, the sensitivity analysis predicted that the post-shimming magnetic field deviation due to assembly errors would remain below 0.1 ppm, demonstrating the method's robustness. This approach provides greater flexibility and ease of implementation than traditional methods, offering a reliable solution for small-aperture MRI superconducting magnets. Future work will focus on further reduction of field inhomogeneity (e.g., 2–3 ppm) for enhanced imaging precision.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-6
Passive Shimming of a 7T Cryogen-Free MRI Superconducting Magnet via Iron Strip Arrangement
The conventional iron matrix shimming method is highly sensitive to the positional variations, especially in small-aperture magnets where limited space imposes significant constraints on feasibility and precision. To address these challenges, this work studied an iron-strip shimming approach following superconducting shimming, replacing the traditional iron matrix scheme for a 7 T/54 mm micro-imaging MRI magnet. A key objective was to realize a 30 mm magnetic field homogenous area, three times larger than that of the typical 10 mm region in common nuclear magnetic resonance (NMR) magnets. To conserve space and leaving enough room for small animal placement, iron strips were positioned around the outer periphery of the gradient assembly, with the iron thickness limited to remain below 0.2 mm, ensuring no interference with gradient assembly installation. This configuration minimized mutual interactions among the iron strips and maximized field homogeneity. Experimental results showed that the peak-peak field homogeneity improved from 11.12 ppm to 4.82 ppm, presenting a 56% enhancement. Additionally, the sensitivity analysis predicted that the post-shimming magnetic field deviation due to assembly errors would remain below 0.1 ppm, demonstrating the method's robustness. This approach provides greater flexibility and ease of implementation than traditional methods, offering a reliable solution for small-aperture MRI superconducting magnets. Future work will focus on further reduction of field inhomogeneity (e.g., 2–3 ppm) for enhanced imaging precision.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (1) , 1-6
Design and Performance Evaluation of a 9.0-T Frameless Conduction-Cooled Superconducting Magnet
A 9.0-T frameless conduction-cooled superconducting magnet has been successfully developed in Wuhan National High Magnetic Field Center. The electromagnetic design was accomplished using a hybrid global optimization method. The magnet features a cold clear bore of 95 mm. Compared with the first 9.0 T conduction-cooled superconducting magnet with frames developed previously, the frameless design reduces superconducting wire consumption by 17% and lowers the total magnet weight by 29%, while preserving the same cold clear bore size and homogeneity in the 10-mm diameter of spherical volume. Low temperature is achieved using one pulse tube cryocooler, enabling the magnet to reach temperatures below 4.2 K from room temperature. The vertical magnet comprises five coaxial NbTi superconducting coils connected in series, operating at a current of 79.73 A for a magnetic field intensity of 9.0 T, with a total magnetic energy storage of 0.14 MJ. A passive quench protection system is implemented by subdividing the coils, which protects the magnet by enabling the quench to propagate to more coils. The frameless design eliminates sliding interfaces between the coils and structural frames, preventing friction-induced joule heating during excitation and significantly reducing the occurrence of training quenches. This novel design demonstrates improved efficiency and reliability for conduction-cooled superconducting magnet systems.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (1) , 1-6
Design and Performance Evaluation of a 9.0-T Frameless Conduction-Cooled Superconducting Magnet
A 9.0-T frameless conduction-cooled superconducting magnet has been successfully developed in Wuhan National High Magnetic Field Center. The electromagnetic design was accomplished using a hybrid global optimization method. The magnet features a cold clear bore of 95 mm. Compared with the first 9.0 T conduction-cooled superconducting magnet with frames developed previously, the frameless design reduces superconducting wire consumption by 17% and lowers the total magnet weight by 29%, while preserving the same cold clear bore size and homogeneity in the 10-mm diameter of spherical volume. Low temperature is achieved using one pulse tube cryocooler, enabling the magnet to reach temperatures below 4.2 K from room temperature. The vertical magnet comprises five coaxial NbTi superconducting coils connected in series, operating at a current of 79.73 A for a magnetic field intensity of 9.0 T, with a total magnetic energy storage of 0.14 MJ. A passive quench protection system is implemented by subdividing the coils, which protects the magnet by enabling the quench to propagate to more coils. The frameless design eliminates sliding interfaces between the coils and structural frames, preventing friction-induced joule heating during excitation and significantly reducing the occurrence of training quenches. This novel design demonstrates improved efficiency and reliability for conduction-cooled superconducting magnet systems.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (6) , 1-7
Electromagnetic and Cryogenic Design of a Liquid-Helium-Free 9-T NbTi Magnet for Scanning Tunneling Microscopy
The strong magnetic field generated by the superconducting magnet can significantly enhance the capabilities of scanning tunneling microscopy (STM) in exploring novel quantum materials, nano-magnetic systems, and topological materials. A liquid-helium-free 9-T NbTi magnet for STM has been developed at the Wuhan National High Magnetic Field Center and is entirely cooled with a Gifford-McMahon (GM) cryocooler. This magnet features five independent coils, a cold bore diameter of 95 mm, a rated operating current of 80.7 A, and a rated central magnetic field of 9.0 T. The magnetic field uniformity over a 1-cm diameter spherical volume is 0.1%. This article presents the electromagnetic and cryogenic design of the magnet, along with a thermal and mechanical analysis and optimization of the current leads and cooling paths. The optimized magnet system successfully reaches a temperature below 4 K. After six training quenches, the magnet was successfully ramped to and parked at 9.2 T.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (6) , 1-7
Electromagnetic and Cryogenic Design of a Liquid-Helium-Free 9-T NbTi Magnet for Scanning Tunneling Microscopy
The strong magnetic field generated by the superconducting magnet can significantly enhance the capabilities of scanning tunneling microscopy (STM) in exploring novel quantum materials, nano-magnetic systems, and topological materials. A liquid-helium-free 9-T NbTi magnet for STM has been developed at the Wuhan National High Magnetic Field Center and is entirely cooled with a Gifford-McMahon (GM) cryocooler. This magnet features five independent coils, a cold bore diameter of 95 mm, a rated operating current of 80.7 A, and a rated central magnetic field of 9.0 T. The magnetic field uniformity over a 1-cm diameter spherical volume is 0.1%. This article presents the electromagnetic and cryogenic design of the magnet, along with a thermal and mechanical analysis and optimization of the current leads and cooling paths. The optimized magnet system successfully reaches a temperature below 4 K. After six training quenches, the magnet was successfully ramped to and parked at 9.2 T.
- 8 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (6) , 1-5
Design, Test, and Shimming of a 1.5-T Head-Only MRI Superconducting Magnet
As the core component of magnetic resonance imaging (MRI) system, superconducting magnet provides a high-intensity, stable, and homogeneous magnetic field background for the system. The strength, stability, and homogeneity of the magnetic field directly affect the imaging quality of MRI. This article presents the design, test, and shimming of a 1.5-T head-only MRI superconducting magnet developed by the Wuhan National High Magnetic Field Center. The magnet consists of seven primary coils and two shielding coils and is operated at an operating current of 510 A using bath cooling. The test has shown that the magnet reached the target field of 1.5 T directly after the first ramp-up without any quench. Under the magnetic field of 1.5 T, the magnetic field decay rate of the magnet is less than 0.02 ppm/hr. After three rounds of passive shimming, the magnet achieves a magnetic field inhomogeneity of 2.89 ppm over an imaging sphere within a diameter of 26 cm. The successful development of this magnet provides practical engineering validation for the lightweight technology of head-only MRI superconducting magnets.
- 8 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (6) , 1-5
Design, Test, and Shimming of a 1.5-T Head-Only MRI Superconducting Magnet
As the core component of magnetic resonance imaging (MRI) system, superconducting magnet provides a high-intensity, stable, and homogeneous magnetic field background for the system. The strength, stability, and homogeneity of the magnetic field directly affect the imaging quality of MRI. This article presents the design, test, and shimming of a 1.5-T head-only MRI superconducting magnet developed by the Wuhan National High Magnetic Field Center. The magnet consists of seven primary coils and two shielding coils and is operated at an operating current of 510 A using bath cooling. The test has shown that the magnet reached the target field of 1.5 T directly after the first ramp-up without any quench. Under the magnetic field of 1.5 T, the magnetic field decay rate of the magnet is less than 0.02 ppm/hr. After three rounds of passive shimming, the magnet achieves a magnetic field inhomogeneity of 2.89 ppm over an imaging sphere within a diameter of 26 cm. The successful development of this magnet provides practical engineering validation for the lightweight technology of head-only MRI superconducting magnets.
- 6 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (9) , 1-6
Thermal Analysis of Persistent Current Switch for Magnetic Resonance Imaging Superconducting Magnet
A superconducting switch, which allows a magnetic resonance imaging (MRI) magnet to be ramped up to its designed magnetic field and parked in a persistent state, is designed, analyzed, and under construction in Wuhan National High Magnetic Field Center. It is a thermally controlled liquid-helium-cooled superconducting switch, consisting of bobbins, flanges, bifilar-wound superconducting coils, and a heater. The multifilament NbTi wire and cable with CuNi matrix are adopted due to their high resistance characteristic, which can reduce helium boil-off volume during operation. Two distinct finite-element analyses, ANSYS Parametric Design Language and COMSOL, are adopted to analyze and compare the key parameters of the superconducting switch, which include its temperature profile and resistance over time. The key parameters’ results of these two models match well. The switch has a nominal resistance of 18.88 Ω. The transition time from the superconducting state to the normal state is less than 4.5 s with heater's current of 0.4 A.
- 6 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (9) , 1-6
Thermal Analysis of Persistent Current Switch for Magnetic Resonance Imaging Superconducting Magnet
A superconducting switch, which allows a magnetic resonance imaging (MRI) magnet to be ramped up to its designed magnetic field and parked in a persistent state, is designed, analyzed, and under construction in Wuhan National High Magnetic Field Center. It is a thermally controlled liquid-helium-cooled superconducting switch, consisting of bobbins, flanges, bifilar-wound superconducting coils, and a heater. The multifilament NbTi wire and cable with CuNi matrix are adopted due to their high resistance characteristic, which can reduce helium boil-off volume during operation. Two distinct finite-element analyses, ANSYS Parametric Design Language and COMSOL, are adopted to analyze and compare the key parameters of the superconducting switch, which include its temperature profile and resistance over time. The key parameters’ results of these two models match well. The switch has a nominal resistance of 18.88 Ω. The transition time from the superconducting state to the normal state is less than 4.5 s with heater's current of 0.4 A.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Quench Protection Design of a Head-Only 1.5 T MRI Superconducting Magnet
This article presents a quench protection design of a head-only 1.5 T MRI superconducting magnet with bath-cooling in Wuhan National High Magnetic Field Center (WHMFC). The magnet consists of nine coaxial solenoid coils fabricated with NbTi wire with a copper to non-copper ratio of eight. It operates at around 510 A with a total storage energy of 0.59 MJ. A passive quench protection circuit with a heater network is employed to protect the magnet from damage during the quench event. The quench protection circuit consists of a set of diodes and a heater network. The diode assembly is composed of two groups of two diodes connected in series and then reverse-parallel. The heater network is composed of 18 heaters connected in parallel and each coil's surface is glued with two heaters arranged at 0° and 180°, respectively. Different quench scenarios are simulated and analyzed, and the simulation results show that the quench protection circuit can effectively protect this magnet from damage.
- 8 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Quench Protection Design of a Head-Only 1.5 T MRI Superconducting Magnet
This article presents a quench protection design of a head-only 1.5 T MRI superconducting magnet with bath-cooling in Wuhan National High Magnetic Field Center (WHMFC). The magnet consists of nine coaxial solenoid coils fabricated with NbTi wire with a copper to non-copper ratio of eight. It operates at around 510 A with a total storage energy of 0.59 MJ. A passive quench protection circuit with a heater network is employed to protect the magnet from damage during the quench event. The quench protection circuit consists of a set of diodes and a heater network. The diode assembly is composed of two groups of two diodes connected in series and then reverse-parallel. The heater network is composed of 18 heaters connected in parallel and each coil's surface is glued with two heaters arranged at 0° and 180°, respectively. Different quench scenarios are simulated and analyzed, and the simulation results show that the quench protection circuit can effectively protect this magnet from damage.
- 29 December 2023
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 37 (2) , 025004
Quench analysis of a no-insulation REBCO magnet based on the ADI method considering the coupling effect of the cryostat
A no-insulation (NI) REBCO superconducting magnet is under development at Wuhan National High Magnetic Field Center, China. The magnet with the liquid helium cryostat system has a compact structure to reduce the space required for operation. During a quench, the fast-changing spatial magnetic field around the NI magnet may induce a strong eddy current in the conductive parts of the cryostat. The eddy current and its associated Lorentz force will generate mechanical stress on the cryostat, especially on the thermal shield (TS). The mechanical strength of the cryostat needs verification in the preliminary design. Furthermore, the degree to which the electromagnetic coupling between the cryostat and NI magnet might impact the quench behaviors of the NI magnet remains uncertain. In this paper, a multi-physics quench model is newly developed for the NI REBCO magnet, and the alternating direction implicit method is employed for the solver of the thermal model to improve computational efficiency. This simulation model can consider the electromagnetic coupling effect between the NI magnet and cryostat by constructing a partial element equivalent circuit. A quench analysis has been performed and we found that: (1) The cryostat can function as a secondary shorted circuit to the NI magnet and slow down the quench speed to a certain extent. (2) During the rather fast inductive quench phase, the cryostat will experience an attraction force towards the quench propagation frontier. (3) A quench propagation from one end of the magnet can cause a significant z-axis unbalanced force on the TS. (4) Cryostat materials with drastically changed electrical conductivity can significantly affect their mechanical responses during a quench. However, the eddy current density and maximum Von Mises stress on the TS are barely affected by the thickness of the TS and the contact resistance of the NI REBCO magnet.
- 29 December 2023
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 37 (2) , 025004
Quench analysis of a no-insulation REBCO magnet based on the ADI method considering the coupling effect of the cryostat
A no-insulation (NI) REBCO superconducting magnet is under development at Wuhan National High Magnetic Field Center, China. The magnet with the liquid helium cryostat system has a compact structure to reduce the space required for operation. During a quench, the fast-changing spatial magnetic field around the NI magnet may induce a strong eddy current in the conductive parts of the cryostat. The eddy current and its associated Lorentz force will generate mechanical stress on the cryostat, especially on the thermal shield (TS). The mechanical strength of the cryostat needs verification in the preliminary design. Furthermore, the degree to which the electromagnetic coupling between the cryostat and NI magnet might impact the quench behaviors of the NI magnet remains uncertain. In this paper, a multi-physics quench model is newly developed for the NI REBCO magnet, and the alternating direction implicit method is employed for the solver of the thermal model to improve computational efficiency. This simulation model can consider the electromagnetic coupling effect between the NI magnet and cryostat by constructing a partial element equivalent circuit. A quench analysis has been performed and we found that: (1) The cryostat can function as a secondary shorted circuit to the NI magnet and slow down the quench speed to a certain extent. (2) During the rather fast inductive quench phase, the cryostat will experience an attraction force towards the quench propagation frontier. (3) A quench propagation from one end of the magnet can cause a significant z-axis unbalanced force on the TS. (4) Cryostat materials with drastically changed electrical conductivity can significantly affect their mechanical responses during a quench. However, the eddy current density and maximum Von Mises stress on the TS are barely affected by the thickness of the TS and the contact resistance of the NI REBCO magnet.