JLJianglan Li

Jianglan Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jianglan Li has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Review of superconducting vector magnet technology: topology, electromagnetic design, and challenges

    by Jianglan Li, Zhiwen Cheng, Yunxing Song

    Superconducting vector magnets can generate steady, controllable magnetic fields in three-dimensional space and have gradually become an important approach for realising high-field vector magnetic environments in advanced scientific applications. As a key external-field parameter in frontier research areas such as quantum computing, strongly correlated electron systems, topological phases of matter, and spintronic devices, vector magnetic fields are subject to increasingly stringent requirements in terms of field magnitude, directional control accuracy, and operational stability. Compared with sample rotators, permanent-magnet arrays, and pulsed vector magnets, superconducting vector magnets offer significant advantages in high field strength, high field homogeneity, long-term stable operation, and compatibility with cryogenic environments. This paper provides a systematic overview of mainstream approaches to vector magnetic field generation, with a particular focus on superconducting vector magnets. First, the major schemes for generating vector magnetic fields are classified and compared, and their performance limits and applicable scenarios are analysed. Second, the electromagnetic design theories of representative superconducting vector magnet topologies are reviewed. In accordance with the chronological sequence of their development, the core logic and theoretical foundations of each design theory are introduced, the characteristics and performance of typical topologies under each design theory are evaluated, and the evolutionary trends in superconducting vector magnet design theory are summarised. Finally, the key technical challenges facing the future development of superconducting vector magnets are discussed. This paper aims to provide a systematic reference for the design and application of high-performance superconducting vector magnets.

  • Design and Performance Evaluation of a 9.0-T Frameless Conduction-Cooled Superconducting Magnet

    by Zhiwen Cheng, Jianglan Li, Xian Li, Mengyu Liu, Liang Li, Qiuliang Wang, Yunxing Song

    A 9.0-T frameless conduction-cooled superconducting magnet has been successfully developed in Wuhan National High Magnetic Field Center. The electromagnetic design was accomplished using a hybrid global optimization method. The magnet features a cold clear bore of 95 mm. Compared with the first 9.0 T conduction-cooled superconducting magnet with frames developed previously, the frameless design reduces superconducting wire consumption by 17% and lowers the total magnet weight by 29%, while preserving the same cold clear bore size and homogeneity in the 10-mm diameter of spherical volume. Low temperature is achieved using one pulse tube cryocooler, enabling the magnet to reach temperatures below 4.2 K from room temperature. The vertical magnet comprises five coaxial NbTi superconducting coils connected in series, operating at a current of 79.73 A for a magnetic field intensity of 9.0 T, with a total magnetic energy storage of 0.14 MJ. A passive quench protection system is implemented by subdividing the coils, which protects the magnet by enabling the quench to propagate to more coils. The frameless design eliminates sliding interfaces between the coils and structural frames, preventing friction-induced joule heating during excitation and significantly reducing the occurrence of training quenches. This novel design demonstrates improved efficiency and reliability for conduction-cooled superconducting magnet systems.


  • Electromagnetic and Cryogenic Design of a Liquid-Helium-Free 9-T NbTi Magnet for Scanning Tunneling Microscopy

    by Yunxing Song, Jianglan Li, Zhiwen Cheng, Mengyu Liu, Xian Li, Liang Li, Qiuliang Wang

    The strong magnetic field generated by the superconducting magnet can significantly enhance the capabilities of scanning tunneling microscopy (STM) in exploring novel quantum materials, nano-magnetic systems, and topological materials. A liquid-helium-free 9-T NbTi magnet for STM has been developed at the Wuhan National High Magnetic Field Center and is entirely cooled with a Gifford-McMahon (GM) cryocooler. This magnet features five independent coils, a cold bore diameter of 95 mm, a rated operating current of 80.7 A, and a rated central magnetic field of 9.0 T. The magnetic field uniformity over a 1-cm diameter spherical volume is 0.1%. This article presents the electromagnetic and cryogenic design of the magnet, along with a thermal and mechanical analysis and optimization of the current leads and cooling paths. The optimized magnet system successfully reaches a temperature below 4 K. After six training quenches, the magnet was successfully ramped to and parked at 9.2 T.


  • Design, Test, and Shimming of a 1.5-T Head-Only MRI Superconducting Magnet

    by Yunxing Song, Zhiwen Cheng, Xunhuang Jiang, Jianglan Li, Liang Li, Qiuliang Wang

    As the core component of magnetic resonance imaging (MRI) system, superconducting magnet provides a high-intensity, stable, and homogeneous magnetic field background for the system. The strength, stability, and homogeneity of the magnetic field directly affect the imaging quality of MRI. This article presents the design, test, and shimming of a 1.5-T head-only MRI superconducting magnet developed by the Wuhan National High Magnetic Field Center. The magnet consists of seven primary coils and two shielding coils and is operated at an operating current of 510 A using bath cooling. The test has shown that the magnet reached the target field of 1.5 T directly after the first ramp-up without any quench. Under the magnetic field of 1.5 T, the magnetic field decay rate of the magnet is less than 0.02 ppm/hr. After three rounds of passive shimming, the magnet achieves a magnetic field inhomogeneity of 2.89 ppm over an imaging sphere within a diameter of 26 cm. The successful development of this magnet provides practical engineering validation for the lightweight technology of head-only MRI superconducting magnets.


  • Thermal Analysis of a Head-Only 1.5 T Magnetic Resonance Imaging Superconducting Magnet

    by Jianglan Li, Hengkang Zheng, Zhiwen Cheng, Liang Li, Qiuliang Wang, Yunxing Song

    A 1.5 T head-only magnetic resonance imaging (MRI) superconducting magnet with liquid helium (LHe) bath-cooling using NbTi wire has been designed and is being constructed in Wuhan National High Magnetic Field Center (WHMFC). The magnet consists of 9 discretized coils, including five main coils and two bucking coils, wound on two separate stainless steel 304 formers. The magnet is designed to operate at 510 A with a peak field below 3.0 T, load line controlled below 50%, and temperature margin above 1 K. It is critical to accurately evaluate the thermal load of the superconducting magnet system to ensure its zero boil-off normal operation since LHe is very expensive and non-renewable. A detailed heat load model is presented in this paper. The heat load is evaluated by finite element analysis, theoretical formula calculation and empirical formula calculation, which fully considers conduction, radiation and convection. The results indicate that the total head load of the second stage is approximately 0.237 W and that of the first stage is about 20.26 W which is well below the cooling power of the SRDE-412D4 cryocooler used in the magnet system.


  • Research on Soldering Technology of YBCO Splice Joint

    by Jianglan Li, Tianyi Tao, Yunxing Song

    Due to the limitations of the YBCO tape production process, the length of a single YBCO tape is restricted. A joint is created to unite two YBCO tapes when winding superconducting coils with short YBCO tapes. Superconducting magnet functioning is adversely affected by poor joint quality. Soldering experiments of short YBCO–YBCO splice joint samples are performed utilizing a self-made joint soldering device in order to investigate the impact of various parameters on the quality of YBCO tape to YBCO tape splice joints. The influence mechanisms of seven parameters, including soldering temperature, current, holding time, joint length, pressure, type of solder, and type of flux, were examined using the design of experiment approach. In addition, a technique is suggested to improve the conditions for testing and soldering success rate by fitting the response function of various influencing variables through a small number of trials. With a success rate of greater than 96%, the splice joint resistivity at zero field and 77 K was stabilized below 80 ${\rm{n\Omega }} \cdot \mathrm{c}{\mathrm{m}}^2$ .