Charlotte Van Steen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Charlotte Van Steen has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Els Verstrynge
KU Leuven Leuven Belgium
11 shared publications - Eline Vandecruys
Department of Civil Engineering, Materials and Constructions Section KU Leuven Leuven Belgium
6 shared publications Els Verstrynge
Department of Civil Engineering, KU Leuven, Belgium
6 shared publications- Constantijn Martens
Department of Civil Engineering, Materials and Constructions Section KU Leuven Leuven Belgium
4 shared publications - Geert Lombaert
Structural Mechanics, Civil Engineering Department, KU Leuven
3 shared publications Lotfollah Pahlavan
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (10)
Improving monitoring robustness with embedded AE sensors for damage detection in deteriorated reinforced concrete
The acoustic emission (AE) technique has proven successful in detecting various AE sources in reinforced concrete (RC), ranging from crack growth due to mechanical loading to corrosion of the steel reinforcement. Most research, however, has focused on small specimens in laboratory conditions, with monitoring durations rarely exceeding several weeks. Upscaling to long-term monitoring on actual structures remains a challenge. Major concerns in AE sensor deployment on real RC structures are establishing a durable sensor-to-surface coupling over long periods, the high attenuation of AE waves over larger distances, sensor placement in difficult-to-access areas, and the protection of the highly sensitive sensors against environmental factors. Embedded sensors in the bulk material, so‑called ‘smart aggregates', have been proposed as a promising solution to these issues, as they are permanently bonded within the material, match the impedance, and can be placed closer to the emission sources in case of reinforcement corrosion, while being protected by the surrounding concrete. In an effort to improve robustness of AE set-ups for long-term field application, current work assesses the added value of embedded sensors in combination with surface-mounted sensors in two experiments: (1) during rebar corrosion tests in RC prisms and (2) during mechanical loading of a full-scale RC girder.
- 1 October 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (10)
Open AccessImproving monitoring robustness with embedded AE sensors for damage detection in deteriorated reinforced concrete
The acoustic emission (AE) technique has proven successful in detecting various AE sources in reinforced concrete (RC), ranging from crack growth due to mechanical loading to corrosion of the steel reinforcement. Most research, however, has focused on small specimens in laboratory conditions, with monitoring durations rarely exceeding several weeks. Upscaling to long-term monitoring on actual structures remains a challenge. Major concerns in AE sensor deployment on real RC structures are establishing a durable sensor-to-surface coupling over long periods, the high attenuation of AE waves over larger distances, sensor placement in difficult-to-access areas, and the protection of the highly sensitive sensors against environmental factors. Embedded sensors in the bulk material, so‑called ‘smart aggregates', have been proposed as a promising solution to these issues, as they are permanently bonded within the material, match the impedance, and can be placed closer to the emission sources in case of reinforcement corrosion, while being protected by the surrounding concrete. In an effort to improve robustness of AE set-ups for long-term field application, current work assesses the added value of embedded sensors in combination with surface-mounted sensors in two experiments: (1) during rebar corrosion tests in RC prisms and (2) during mechanical loading of a full-scale RC girder.
- Open Access
- 1 October 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (10)
Insights from acoustic emission monitoring of damage caused by a slow steel corrosion process in reinforced concrete beams
Reinforcement corrosion significantly affects the structural integrity and service life of reinforced concrete (RC) structures. Although acoustic emission (AE) monitoring enables early damage detection and localization, its use during slow natural corrosion and in noisy outdoor environments remains challenging. This study evaluates the feasibility of periodic AE monitoring during natural chloride‑induced corrosion of two pre‑damaged RC beams stored outdoors. Two AE sensor types were assessed under realistic environmental conditions, and a dedicated filtering strategy was developed to separate damage‑related signals from environmental noise. Following main novelties are addressed: (1) the application of periodic AE monitoring rather than continuous AE monitoring, (2) the assessment of slow chloride-induced corrosion in RC instead of accelerated corrosion using a direct current, and (3) the consideration of environmental influences such as rain, wind and solar exposure. The results show that periodic AE monitoring can successfully track damage progression and localize corrosion hotspots. These outcomes underscore the potential of AE monitoring for supporting structural health assessment of RC structures in field conditions.
- 1 October 2026
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 31 (10)
Open AccessInsights from acoustic emission monitoring of damage caused by a slow steel corrosion process in reinforced concrete beams
Reinforcement corrosion significantly affects the structural integrity and service life of reinforced concrete (RC) structures. Although acoustic emission (AE) monitoring enables early damage detection and localization, its use during slow natural corrosion and in noisy outdoor environments remains challenging. This study evaluates the feasibility of periodic AE monitoring during natural chloride‑induced corrosion of two pre‑damaged RC beams stored outdoors. Two AE sensor types were assessed under realistic environmental conditions, and a dedicated filtering strategy was developed to separate damage‑related signals from environmental noise. Following main novelties are addressed: (1) the application of periodic AE monitoring rather than continuous AE monitoring, (2) the assessment of slow chloride-induced corrosion in RC instead of accelerated corrosion using a direct current, and (3) the consideration of environmental influences such as rain, wind and solar exposure. The results show that periodic AE monitoring can successfully track damage progression and localize corrosion hotspots. These outcomes underscore the potential of AE monitoring for supporting structural health assessment of RC structures in field conditions.
- 4 July 2026
- Published by SAGE Publications in Structural Health Monitoring
Periodic acoustic emission monitoring of reinforced concrete beams under natural corrosion conditions
Reinforcement corrosion is a critical issue affecting structural integrity and service life of existing reinforced concrete (RC) structures. While acoustic emission (AE) monitoring provides early damage detection and localization, its application during slow natural corrosion processes and in noisy outdoor environments remains challenging. This study investigates the feasibility of periodic AE monitoring during natural chloride-induced corrosion of two pre-damaged RC beams stored outdoors. Two AE sensor types were evaluated under realistic environmental influences. A dedicated filtering approach was developed to distinguish damage-related AE signals from environmental noise. The results demonstrate that periodic AE monitoring can effectively track damage evolution and localize corrosion hotspots in both one dimensional and two dimensional. Furthermore, a previously developed methodology for estimating accelerated corrosion levels based on AE localization was successfully applied to natural corrosion, confirming its broader applicability. These findings highlight the potential of the AE technique for structural health monitoring of RC structures under field conditions.
- 4 July 2026
- Published by SAGE Publications in Structural Health Monitoring
Periodic acoustic emission monitoring of reinforced concrete beams under natural corrosion conditions
Reinforcement corrosion is a critical issue affecting structural integrity and service life of existing reinforced concrete (RC) structures. While acoustic emission (AE) monitoring provides early damage detection and localization, its application during slow natural corrosion processes and in noisy outdoor environments remains challenging. This study investigates the feasibility of periodic AE monitoring during natural chloride-induced corrosion of two pre-damaged RC beams stored outdoors. Two AE sensor types were evaluated under realistic environmental influences. A dedicated filtering approach was developed to distinguish damage-related AE signals from environmental noise. The results demonstrate that periodic AE monitoring can effectively track damage evolution and localize corrosion hotspots in both one dimensional and two dimensional. Furthermore, a previously developed methodology for estimating accelerated corrosion levels based on AE localization was successfully applied to natural corrosion, confirming its broader applicability. These findings highlight the potential of the AE technique for structural health monitoring of RC structures under field conditions.
- 15 October 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (5) , 5578-5595
Corrosion level estimation in reinforced concrete beams by acoustic emission sensing and selective crack measurements
Accurate corrosion assessment plays an important role in ensuring structural safety of reinforced concrete (RC) structures. However, on‐site assessment of existing concrete structures presents many challenges, including high costs, limited inspection timeframes, and difficult accessibility. To facilitate inspection‐based corrosion assessment, this paper presents a novel approach by combining short‐term acoustic emission (AE) monitoring with selective crack width measurements for corrosion level (CL) assessment. AE sensing is a monitoring technique which can detect ongoing internal degradation mechanisms by analyzing ultrasonic waves emitted by the damage process. Yet, two major challenges arise on site: (1) practical limitations prevent continuous AE monitoring over the structure's entire lifetime and (2) AE can only generate relative results in the absence of reference measurements. This paper addresses both challenges to bridge the gap between laboratory experiments and on‐site monitoring of corroding RC structures. First, short periods of AE monitoring data are analyzed to investigate the potential of AE sensing over limited timeframes. Second, AE data of corroding RC beams are combined with sparse crack width measurements in order to obtain absolute CLs. The proposed methodology is experimentally validated by corroding eight beams with varying dimensions, corrosion zones, and reinforcement layouts. The experimental results prove that the estimated CLs closely match the rebar mass losses, with a mean absolute error of 1.53% CL for beams reaching up to 14% CL, confirming the potential of the combined AE and crack width measurement technique as an efficient and accurate condition assessment approach. Moreover, AE sensing provides detailed spatial variability of the rebar corrosion in the monitored zone, which is challenging to obtain with conventional techniques. By using this dual‐technique approach, shorter monitoring periods prove nearly as effective as continuous AE monitoring in accurately estimating CLs.
- 15 October 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (5) , 5578-5595
Corrosion level estimation in reinforced concrete beams by acoustic emission sensing and selective crack measurements
Accurate corrosion assessment plays an important role in ensuring structural safety of reinforced concrete (RC) structures. However, on‐site assessment of existing concrete structures presents many challenges, including high costs, limited inspection timeframes, and difficult accessibility. To facilitate inspection‐based corrosion assessment, this paper presents a novel approach by combining short‐term acoustic emission (AE) monitoring with selective crack width measurements for corrosion level (CL) assessment. AE sensing is a monitoring technique which can detect ongoing internal degradation mechanisms by analyzing ultrasonic waves emitted by the damage process. Yet, two major challenges arise on site: (1) practical limitations prevent continuous AE monitoring over the structure's entire lifetime and (2) AE can only generate relative results in the absence of reference measurements. This paper addresses both challenges to bridge the gap between laboratory experiments and on‐site monitoring of corroding RC structures. First, short periods of AE monitoring data are analyzed to investigate the potential of AE sensing over limited timeframes. Second, AE data of corroding RC beams are combined with sparse crack width measurements in order to obtain absolute CLs. The proposed methodology is experimentally validated by corroding eight beams with varying dimensions, corrosion zones, and reinforcement layouts. The experimental results prove that the estimated CLs closely match the rebar mass losses, with a mean absolute error of 1.53% CL for beams reaching up to 14% CL, confirming the potential of the combined AE and crack width measurement technique as an efficient and accurate condition assessment approach. Moreover, AE sensing provides detailed spatial variability of the rebar corrosion in the monitored zone, which is challenging to obtain with conventional techniques. By using this dual‐technique approach, shorter monitoring periods prove nearly as effective as continuous AE monitoring in accurately estimating CLs.
- Open Access
- 1 October 2024
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 29 (10)
Acoustic emission monitoring of a large-scale 50-year-old prestressed concrete bridge girder during an eccentric three-point bending test
Deterioration of reinforced and prestressed concrete structures is one of the main challenges in structural engineering. As the majority of our infrastructure is built around 1960-1980, most structures have reached or will soon reach their design lifetime, giving rise to more structural problems and costs in the coming decades. It is therefore important to develop efficient assessment schemes allowing to assure the safety and reliability of these existing structures and to estimate their residual lifetime. Within the framework of the Bridge|50 research project, a 50-year-old prestressed concrete bridge showing signs of corrosion damage was decommissioned. The bridge girders were recovered and have been subjected to large-scale load tests with varying loading patterns. This paper presents the results acquired during acoustic emission (AE) monitoring of one of the I-shaped girders during a monotonic three-point bending test with an eccentric point load. The results show that the failure mode and location could be detected based on AE activity and zonal AE localization. The onset of concrete cracking was observed by a decrease in peak frequency of the AE signals. Average frequency (AF) and rise angle (RA) value analysis was used to characterize the crack mode, which shifted from tensile to shear mode during bending.
- 1 October 2024
- Published by NDT.net GmbH & Co. KG in e-Journal of Nondestructive Testing
- Vol. 29 (10)
Open AccessAcoustic emission monitoring of a large-scale 50-year-old prestressed concrete bridge girder during an eccentric three-point bending test
Deterioration of reinforced and prestressed concrete structures is one of the main challenges in structural engineering. As the majority of our infrastructure is built around 1960-1980, most structures have reached or will soon reach their design lifetime, giving rise to more structural problems and costs in the coming decades. It is therefore important to develop efficient assessment schemes allowing to assure the safety and reliability of these existing structures and to estimate their residual lifetime. Within the framework of the Bridge|50 research project, a 50-year-old prestressed concrete bridge showing signs of corrosion damage was decommissioned. The bridge girders were recovered and have been subjected to large-scale load tests with varying loading patterns. This paper presents the results acquired during acoustic emission (AE) monitoring of one of the I-shaped girders during a monotonic three-point bending test with an eccentric point load. The results show that the failure mode and location could be detected based on AE activity and zonal AE localization. The onset of concrete cracking was observed by a decrease in peak frequency of the AE signals. Average frequency (AF) and rise angle (RA) value analysis was used to characterize the crack mode, which shifted from tensile to shear mode during bending.
- 2 August 2024
- Published by Elsevier in Construction and Building Materials
- Vol. 443
Smart aggregates for acoustic emission monitoring of concrete cracking and reinforcement corrosion
- 2 August 2024
- Published by Elsevier in Construction and Building Materials
- Vol. 443
Smart aggregates for acoustic emission monitoring of concrete cracking and reinforcement corrosion
- 20 February 2024
- Published by Springer Nature
- p. 1166-1177
Corrosion Level Prediction with Acoustic Emission Sensing and Crack Measurements
- 20 February 2024
- Published by Springer Nature
- p. 1166-1177
Corrosion Level Prediction with Acoustic Emission Sensing and Crack Measurements
- 9 August 2023
- Published by Elsevier in Engineering Structures
- Vol. 294
A two-phased modelling approach for corrosion-induced concrete cracking and bond deterioration in reinforced concrete
- 9 August 2023
- Published by Elsevier in Engineering Structures
- Vol. 294
A two-phased modelling approach for corrosion-induced concrete cracking and bond deterioration in reinforced concrete