Constantijn Martens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Constantijn Martens has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Charlotte Van Steen
Department of Civil Engineering, KU Leuven, Belgium
4 shared publications - Eline Vandecruys
Department of Civil Engineering, Materials and Constructions Section KU Leuven Leuven Belgium
4 shared publications - Els Verstrynge
KU Leuven Leuven Belgium
3 shared publications Els Verstrynge
Department of Civil Engineering, KU Leuven, Belgium
2 shared publications- Geert Lombaert
Structural Mechanics, Civil Engineering Department, KU Leuven
2 shared publications Max Fiedler
1 shared publication
Latest Publications
- 4 July 2026
- Published by SAGE Publications in Structural Health Monitoring
Periodic acoustic emission monitoring of reinforced concrete beams under natural corrosion conditions
Reinforcement corrosion is a critical issue affecting structural integrity and service life of existing reinforced concrete (RC) structures. While acoustic emission (AE) monitoring provides early damage detection and localization, its application during slow natural corrosion processes and in noisy outdoor environments remains challenging. This study investigates the feasibility of periodic AE monitoring during natural chloride-induced corrosion of two pre-damaged RC beams stored outdoors. Two AE sensor types were evaluated under realistic environmental influences. A dedicated filtering approach was developed to distinguish damage-related AE signals from environmental noise. The results demonstrate that periodic AE monitoring can effectively track damage evolution and localize corrosion hotspots in both one dimensional and two dimensional. Furthermore, a previously developed methodology for estimating accelerated corrosion levels based on AE localization was successfully applied to natural corrosion, confirming its broader applicability. These findings highlight the potential of the AE technique for structural health monitoring of RC structures under field conditions.
- 4 July 2026
- Published by SAGE Publications in Structural Health Monitoring
Periodic acoustic emission monitoring of reinforced concrete beams under natural corrosion conditions
Reinforcement corrosion is a critical issue affecting structural integrity and service life of existing reinforced concrete (RC) structures. While acoustic emission (AE) monitoring provides early damage detection and localization, its application during slow natural corrosion processes and in noisy outdoor environments remains challenging. This study investigates the feasibility of periodic AE monitoring during natural chloride-induced corrosion of two pre-damaged RC beams stored outdoors. Two AE sensor types were evaluated under realistic environmental influences. A dedicated filtering approach was developed to distinguish damage-related AE signals from environmental noise. The results demonstrate that periodic AE monitoring can effectively track damage evolution and localize corrosion hotspots in both one dimensional and two dimensional. Furthermore, a previously developed methodology for estimating accelerated corrosion levels based on AE localization was successfully applied to natural corrosion, confirming its broader applicability. These findings highlight the potential of the AE technique for structural health monitoring of RC structures under field conditions.
- 15 October 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (5) , 5578-5595
Corrosion level estimation in reinforced concrete beams by acoustic emission sensing and selective crack measurements
Accurate corrosion assessment plays an important role in ensuring structural safety of reinforced concrete (RC) structures. However, on‐site assessment of existing concrete structures presents many challenges, including high costs, limited inspection timeframes, and difficult accessibility. To facilitate inspection‐based corrosion assessment, this paper presents a novel approach by combining short‐term acoustic emission (AE) monitoring with selective crack width measurements for corrosion level (CL) assessment. AE sensing is a monitoring technique which can detect ongoing internal degradation mechanisms by analyzing ultrasonic waves emitted by the damage process. Yet, two major challenges arise on site: (1) practical limitations prevent continuous AE monitoring over the structure's entire lifetime and (2) AE can only generate relative results in the absence of reference measurements. This paper addresses both challenges to bridge the gap between laboratory experiments and on‐site monitoring of corroding RC structures. First, short periods of AE monitoring data are analyzed to investigate the potential of AE sensing over limited timeframes. Second, AE data of corroding RC beams are combined with sparse crack width measurements in order to obtain absolute CLs. The proposed methodology is experimentally validated by corroding eight beams with varying dimensions, corrosion zones, and reinforcement layouts. The experimental results prove that the estimated CLs closely match the rebar mass losses, with a mean absolute error of 1.53% CL for beams reaching up to 14% CL, confirming the potential of the combined AE and crack width measurement technique as an efficient and accurate condition assessment approach. Moreover, AE sensing provides detailed spatial variability of the rebar corrosion in the monitored zone, which is challenging to obtain with conventional techniques. By using this dual‐technique approach, shorter monitoring periods prove nearly as effective as continuous AE monitoring in accurately estimating CLs.
- 15 October 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (5) , 5578-5595
Corrosion level estimation in reinforced concrete beams by acoustic emission sensing and selective crack measurements
Accurate corrosion assessment plays an important role in ensuring structural safety of reinforced concrete (RC) structures. However, on‐site assessment of existing concrete structures presents many challenges, including high costs, limited inspection timeframes, and difficult accessibility. To facilitate inspection‐based corrosion assessment, this paper presents a novel approach by combining short‐term acoustic emission (AE) monitoring with selective crack width measurements for corrosion level (CL) assessment. AE sensing is a monitoring technique which can detect ongoing internal degradation mechanisms by analyzing ultrasonic waves emitted by the damage process. Yet, two major challenges arise on site: (1) practical limitations prevent continuous AE monitoring over the structure's entire lifetime and (2) AE can only generate relative results in the absence of reference measurements. This paper addresses both challenges to bridge the gap between laboratory experiments and on‐site monitoring of corroding RC structures. First, short periods of AE monitoring data are analyzed to investigate the potential of AE sensing over limited timeframes. Second, AE data of corroding RC beams are combined with sparse crack width measurements in order to obtain absolute CLs. The proposed methodology is experimentally validated by corroding eight beams with varying dimensions, corrosion zones, and reinforcement layouts. The experimental results prove that the estimated CLs closely match the rebar mass losses, with a mean absolute error of 1.53% CL for beams reaching up to 14% CL, confirming the potential of the combined AE and crack width measurement technique as an efficient and accurate condition assessment approach. Moreover, AE sensing provides detailed spatial variability of the rebar corrosion in the monitored zone, which is challenging to obtain with conventional techniques. By using this dual‐technique approach, shorter monitoring periods prove nearly as effective as continuous AE monitoring in accurately estimating CLs.
- 11 October 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (5) , 5743-5760
Bayesian updating of relationships between crack width and corrosion level in reinforced concrete based on a large set of experimental data
The evaluation of rebar corrosion in reinforced concrete (RC) structures presents a significant challenge for structural engineers, with on‐site visual inspections and crack width measurements playing a key role in the preliminary assessment. A general approach is to use corrosion models to predict the corrosion level of existing structures, and subsequently update these predictions by means of on‐site data. In this process, empirical models are often applied that relate the observed damage, such as corrosion‐induced cracks, to the corrosion level. However, these models have large uncertainties and are often not applicable to conditions that deviate from the test setups used to derive the empirical relations. This research aims to expand the applicability of these practical, existing empirical models for on‐site corrosion assessment through Bayesian updating techniques. To this aim, a Bayesian framework is developed to update crack width–corrosion models. The Bayesian updating methodology is illustrated for a simple regression model, and for a more complex relation that accounts for additional variables. A novel online database (KUL‐edCCRC) is used that is published accompanying this paper. The obtained results illustrate that the updated models have better agreement with the experimental results, and it is found that the confidence intervals of the regression parameters decrease for an increasing number of observations, even for a small number of additional datapoints. The results hence prove the efficiency of the approach to integrate information from new observations with prior information to adjust the crack width–corrosion model for specific conditions or cases, resulting in a more relevant model as more information becomes available.
- 11 October 2024
- Published by Wiley in Structural Concrete
- Vol. 26 (5) , 5743-5760
Bayesian updating of relationships between crack width and corrosion level in reinforced concrete based on a large set of experimental data
The evaluation of rebar corrosion in reinforced concrete (RC) structures presents a significant challenge for structural engineers, with on‐site visual inspections and crack width measurements playing a key role in the preliminary assessment. A general approach is to use corrosion models to predict the corrosion level of existing structures, and subsequently update these predictions by means of on‐site data. In this process, empirical models are often applied that relate the observed damage, such as corrosion‐induced cracks, to the corrosion level. However, these models have large uncertainties and are often not applicable to conditions that deviate from the test setups used to derive the empirical relations. This research aims to expand the applicability of these practical, existing empirical models for on‐site corrosion assessment through Bayesian updating techniques. To this aim, a Bayesian framework is developed to update crack width–corrosion models. The Bayesian updating methodology is illustrated for a simple regression model, and for a more complex relation that accounts for additional variables. A novel online database (KUL‐edCCRC) is used that is published accompanying this paper. The obtained results illustrate that the updated models have better agreement with the experimental results, and it is found that the confidence intervals of the regression parameters decrease for an increasing number of observations, even for a small number of additional datapoints. The results hence prove the efficiency of the approach to integrate information from new observations with prior information to adjust the crack width–corrosion model for specific conditions or cases, resulting in a more relevant model as more information becomes available.
- 20 February 2024
- Published by Springer Nature
- p. 1166-1177
Corrosion Level Prediction with Acoustic Emission Sensing and Crack Measurements
- 20 February 2024
- Published by Springer Nature
- p. 1166-1177
Corrosion Level Prediction with Acoustic Emission Sensing and Crack Measurements