XLXianyou Li

Xianyou Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xianyou Li has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Ke Xu

    Collaborative Innovation Center of Steel Technology, University of Science and Technology Beijing, Beijing 100083, China

    3 shared publications
  • Shun Wang

    Collaborative Innovation Center of Steel Technology, University of Science and Technology Beijing, Beijing 100083, China

    3 shared publications
  • Yufei Zhang

    Department of Mechanical Engineering, Baotou Vocational and Technical College, Baotou 014030, People’s Republic of China

    1 shared publication

Latest Publications

  • Error analysis of precision measurement with monocular vision

    by Shun Wang, Xianyou Li, Yufei Zhang, Ke Xu

    To systematically study the measurement error of the calibration coefficient method when the camera’s optical axis is not perpendicular to the measurement plane, this paper first discusses the principle of error measurement with 2D imaging model, and then derives the distribution relationship of physical points corresponding to evenly distributed pixels in the pixel coordinate system based on the projection transformation matrix of the vision system. Theoretical analysis reveals an equivariance series in the expression of physical point intervals. Considering rotational symmetry of the coordinate axis, this paper analyzes the geometric relationship when the calibration plane rotates around the X axis and derives the mathematical expression for dimensional measurement. Finally, an experimental platform with both industrial and telecentric lenses is proposed and designed. Experimental results demonstrate that the measurement results of the expression derived in this paper are consistent with the traditional coordinate transformation method and the maximum deviation of the measurement is less than 0.06 mm, validating the theoretical analysis presented in this paper and providing theoretical guidance for subsequent practical application.


  • Open Access

    Automatic Measurement of External Thread at the End of Sucker Rod Based on Machine Vision

    by Xianyou Li, Shun Wang, Ke Xu

    Aiming at the low efficiency of manual measurement of threads and the lack of practicability in machine vision measurement before, online size measurement of threads at the end of sucker rods based on machine vision was studied. A robotic arm is used to carry an optical device to achieve high-quality image acquisition of threads. Based on the prior knowledge of the thread profile angle, the directional edge detection operator is customized to achieve the accurate detection of the left and right edges of the thread. Noise filtering, sorting, and left and right edge-matching algorithms based on connected domains are developed to eliminate the interference effects of electrostatic dust and oil pollution in online measurement, and the dimension of thread profile angles, pitches, major diameters, and minor diameters can be precisely calculated. The experimental results show that the screw thread parameter measurement time is about 0.13 s; the maximum and minimum average errors of the thread angles are 0.011° and 0.632°, respectively; and the total average deviation is less than 0.08°. For the screw thread pitch, major diameter, minor diameter, and pitch diameter parameter measurement, the deviation of the measurement results between the proposed method and the universal tool microscope (UTM) method is less than 10 μm. It fully proves the effectiveness and accuracy of the method in this paper and, at the same time, shows that the method has good real-time performance and high application significance, which lays a good foundation for the subsequent online thread measurement.


  • Open Access

    Precision Measurement Method of Large Shaft Diameter Based on Dual Camera System

    by Xianyou Li, Ke Xu, Shun Wang

    At present, there is a problem that the measurement accuracy and measurement range cannot be balanced in the measurement of shaft diameter by the machine vision method. In this paper, we propose a large-scale shaft diameter precision measurement method based on a dual camera measurement system. The unified world coordinate system of the two cameras is established by analyzing the dual camera imaging model and obtaining the measurement formula. In order to verify the validity of the proposed method, two black blocks in the calibration plate with a known center distance of 100 mm were measured. The mean value was 100.001 mm and the standard deviation was 0.00039 in 10 measurements. Finally, the proposed system was applied to the diameter measurement of a complexed crankshaft. The mean μ95 values of CMM and the proposed method were ±1.02 μm and ±1.07 μm, respectively, indicating that the measurement accuracy of the proposed method is roughly equal to the CMM.