Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shun Wang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Online surface defect detection of steel rails using a multi-module optimized YOLO framework

    by Xiangyu Cao, Xin Yang, Shun Wang, Ke Xu, Hualing Zhu, Jianpeng Jiao

  • Design and Evaluation of a Multiview Multispectral Photometric Stereo Instrument for Online Surface Defect Detection of Hot Continuous Casting Slabs

    by Xiangyu Cao, Shun Wang, Hongjie Li, Dongdong Zhou, Ke Xu

    To address the technical challenges in online surface defects detection of hot continuous casting slab (HCCS), this paper presents the design, development, and validation of a novel vision-based instrumentation system based on Multi-View Multispectral Photometric Stereo (MVMSPS). The system integrates four cameras with specific spectral illuminators to intrinsically eliminate spectral crosstalk at inspection speeds up to 0.5 m/s. The core innovations are twofold: 1) A Generalized Homography Transformation (GHT) method is proposed for precise multi-view image matching, reducing geometric alignment errors by over 87.8% compared to conventional methods. 2) The optimal illumination zenith angle under the Lambertian model is theoretically deduced to guide the lighting design and maximize the signal-to-noise ratio. Enabled by these innovations, the MVMSPS algorithm effectively fuses multi-view and multispectral data to effectively estimate the surface normal and capture the high-frequency information of surface depth variations. Experimental results demonstrate that the proposed MVMSPS system can accurately, reliably, and efficiently detect surface defects (e.g., scars, cracks, and indentations) on HCCS in high-temperature and dynamic environments, with a complete processing time of under 3.6s per image set, satisfying the real-time requirements for online inspection and offering a promising instrument solution for intelligent production and quality control in the steel industry. Additionally, this paper explores potential future research directions, including combining fast two-dimensional detection with three-dimensional photometric stereo and integrating multimodal information, to further enhance detection performance.


  • Open Access

    Thickness Measurements with EMAT Based on Fuzzy Logic

    by Yingjie Shi, Shihui Tian, Jiahong Jiang, Tairan Lei, Shun Wang, Xiaobo Lin, Ke Xu

    Metal thickness measurements are essential in various industrial applications, yet current non-contact ultrasonic methods face limitations in range and accuracy, hindering the widespread adoption of electromagnetic ultrasonics. This study introduces a novel combined thickness measurement method employing fuzzy logic, with the aim of broadening the applicational scope of the EMAT. Leveraging minimal hardware, this method utilizes the short pulse time-of-flight (TOF) technique for initial thickness estimation, followed by secondary measurements guided by fuzzy logic principles. The integration of measurements from the resonance, short pulse echo, and linear frequency modulation echo extends the measurement range while enhancing accuracy. Rigorous experimental validation validates the method’s effectiveness, demonstrating a measurement range of 0.3–1000.0 mm with a median error within ±0.5 mm. Outperforming traditional methods like short pulse echoes, this approach holds significant industrial potential.


  • Error analysis of precision measurement with monocular vision

    by Shun Wang, Xianyou Li, Yufei Zhang, Ke Xu

    To systematically study the measurement error of the calibration coefficient method when the camera’s optical axis is not perpendicular to the measurement plane, this paper first discusses the principle of error measurement with 2D imaging model, and then derives the distribution relationship of physical points corresponding to evenly distributed pixels in the pixel coordinate system based on the projection transformation matrix of the vision system. Theoretical analysis reveals an equivariance series in the expression of physical point intervals. Considering rotational symmetry of the coordinate axis, this paper analyzes the geometric relationship when the calibration plane rotates around the X axis and derives the mathematical expression for dimensional measurement. Finally, an experimental platform with both industrial and telecentric lenses is proposed and designed. Experimental results demonstrate that the measurement results of the expression derived in this paper are consistent with the traditional coordinate transformation method and the maximum deviation of the measurement is less than 0.06 mm, validating the theoretical analysis presented in this paper and providing theoretical guidance for subsequent practical application.


  • Open Access

    Automatic Measurement of External Thread at the End of Sucker Rod Based on Machine Vision

    by Xianyou Li, Shun Wang, Ke Xu

    Aiming at the low efficiency of manual measurement of threads and the lack of practicability in machine vision measurement before, online size measurement of threads at the end of sucker rods based on machine vision was studied. A robotic arm is used to carry an optical device to achieve high-quality image acquisition of threads. Based on the prior knowledge of the thread profile angle, the directional edge detection operator is customized to achieve the accurate detection of the left and right edges of the thread. Noise filtering, sorting, and left and right edge-matching algorithms based on connected domains are developed to eliminate the interference effects of electrostatic dust and oil pollution in online measurement, and the dimension of thread profile angles, pitches, major diameters, and minor diameters can be precisely calculated. The experimental results show that the screw thread parameter measurement time is about 0.13 s; the maximum and minimum average errors of the thread angles are 0.011° and 0.632°, respectively; and the total average deviation is less than 0.08°. For the screw thread pitch, major diameter, minor diameter, and pitch diameter parameter measurement, the deviation of the measurement results between the proposed method and the universal tool microscope (UTM) method is less than 10 μm. It fully proves the effectiveness and accuracy of the method in this paper and, at the same time, shows that the method has good real-time performance and high application significance, which lays a good foundation for the subsequent online thread measurement.


  • Open Access

    Precision Measurement Method of Large Shaft Diameter Based on Dual Camera System

    by Xianyou Li, Ke Xu, Shun Wang

    At present, there is a problem that the measurement accuracy and measurement range cannot be balanced in the measurement of shaft diameter by the machine vision method. In this paper, we propose a large-scale shaft diameter precision measurement method based on a dual camera measurement system. The unified world coordinate system of the two cameras is established by analyzing the dual camera imaging model and obtaining the measurement formula. In order to verify the validity of the proposed method, two black blocks in the calibration plate with a known center distance of 100 mm were measured. The mean value was 100.001 mm and the standard deviation was 0.00039 in 10 measurements. Finally, the proposed system was applied to the diameter measurement of a complexed crankshaft. The mean μ95 values of CMM and the proposed method were ±1.02 μm and ±1.07 μm, respectively, indicating that the measurement accuracy of the proposed method is roughly equal to the CMM.