Ole Gade Sørensen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ole Gade Sørensen has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Maiken Stilling
Aarhus University Hospital
2 shared publications - Bart L. Kaptein
Department of Orthopaedics, Leiden University Medical Centre, Leiden, Netherlands
1 shared publication - Daan Koppens
Department of Orthopaedics, Aarhus University Hospital, Denmark
1 shared publication - Emil Toft Petersen
AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
1 shared publication - Kasper Stentz-Olesen
Orthopaedic Research Group, Department of Orthopaedic Surgery, Aarhus University Hospital, Tage-Hansens Gade 2, Building 10A, Office 15, 8000 Aarhus C, Denmark
1 shared publication - Kjeld Søballe
Department of Orthopedic Surgery, Aarhus University Hospital, Aarhus, Denmark
1 shared publication
Latest Publications
- 19 November 2018
- Published by Springer Nature in Skeletal Radiology
- Vol. 48 (7) , 1069-1077
The lateral joint space width can be measured reliably with Telos valgus stress radiography in medial knee osteoarthritis
Objective To examine the reproducibility of valgus stress radiographs with the Telos stress device for assessment of lateral compartment degenerative changes in patients with medial osteoarthritis of the knee. Materials and methods A prospective reliability study was performed. Seventy-nine patients (80 knees) were included, and standardized valgus stress radiographs were obtained using the Telos stress device. Osteophytes and joint space narrowing (JSN) were graded using the OARSI (Osteoarthritis Research Society International) classification, and the joint space width (JSW) was measured in millimeters. Reproducibility was determined as intra-and inter-rater reliability and test–retest reliability. Weighted kappa was used to determine the reliability of osteophyte and JSN grading, and the intra-class correlation coefficient for JSW. Results Grading of osteophytes had an intra- and inter-rater reliability ranging from 0.40 to 0.83 on the medial side and ranging from 0.39 to 0.87 on the lateral side. Grading of medial JSN had an intra- and inter-rater reliability ranging from 0.62 to 0.84, and grading of lateral JSN had an intra- and inter-rater reliability ranging from 0.32 to 0.65. Intra- and inter-rater reliability of JSW ranged from 0.84 to 0.98 on the medial side, and from 0.59 to 0.89 on the lateral side. Test–retest reliability of JSW of the medial and lateral side ranged from 0.69 to 0.92. Conclusions Standardized valgus stress radiographs taken with the Telos stress device are a reliable supplement in the assessment of medial OA of the knee. Evaluation of the lateral compartment on valgus stress radiographs is most reliable with measurement of the lateral JSW.
- 19 November 2018
- Published by Springer Nature in Skeletal Radiology
- Vol. 48 (7) , 1069-1077
The lateral joint space width can be measured reliably with Telos valgus stress radiography in medial knee osteoarthritis
Objective To examine the reproducibility of valgus stress radiographs with the Telos stress device for assessment of lateral compartment degenerative changes in patients with medial osteoarthritis of the knee. Materials and methods A prospective reliability study was performed. Seventy-nine patients (80 knees) were included, and standardized valgus stress radiographs were obtained using the Telos stress device. Osteophytes and joint space narrowing (JSN) were graded using the OARSI (Osteoarthritis Research Society International) classification, and the joint space width (JSW) was measured in millimeters. Reproducibility was determined as intra-and inter-rater reliability and test–retest reliability. Weighted kappa was used to determine the reliability of osteophyte and JSN grading, and the intra-class correlation coefficient for JSW. Results Grading of osteophytes had an intra- and inter-rater reliability ranging from 0.40 to 0.83 on the medial side and ranging from 0.39 to 0.87 on the lateral side. Grading of medial JSN had an intra- and inter-rater reliability ranging from 0.62 to 0.84, and grading of lateral JSN had an intra- and inter-rater reliability ranging from 0.32 to 0.65. Intra- and inter-rater reliability of JSW ranged from 0.84 to 0.98 on the medial side, and from 0.59 to 0.89 on the lateral side. Test–retest reliability of JSW of the medial and lateral side ranged from 0.69 to 0.92. Conclusions Standardized valgus stress radiographs taken with the Telos stress device are a reliable supplement in the assessment of medial OA of the knee. Evaluation of the lateral compartment on valgus stress radiographs is most reliable with measurement of the lateral JSW.
- 17 March 2017
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 25 (4) , 1125-1131
Reconstructing the anterolateral ligament does not decrease rotational knee laxity in ACL-reconstructed knees
Purpose Little is known about the anterolateral ligament’s (ALL) influence on knee laxity. The purpose of this study was to investigate rotational knee laxity against a pure axial rotational stress using radiostereometric analysis (RSA) after cutting and reconstructing both the anterior cruciate ligament (ACL) and the ALL. Methods Eight human donor legs were positioned and stereoradiographically recorded at 0°, 30° and 60° of knee flexion using a motorised fixture, while an internally rotating force of 4 Nm was applied to the foot. Anterior–posterior and rotational laxity were investigated for knees with intact ligaments and compared with those observed after successive ACL and ALL resection and reconstruction. Results After cutting the ALL in ACL-deficient knees, the internal rotation was increased in all three knee flexion angles, 0° (p = 0.04), 30° (p = 0.03) and 60° (p < 0.01) by 1.0°, 1.6° and 2.5°, respectively. However, no decrease in laxity was found after reconstructing the ALL in ACL-reconstructed knees. Conclusions The ALL was confirmed as a stabiliser of internal rotation in ACL-deficient knees. However, reconstructing the ALL using a gracilis autograft tendon did not decrease the internal rotation laxity in the ACL-reconstructed knee. Based on the results of this study, we do not recommend reconstructing the ALL in ACL-reconstructed knees to decrease internal knee laxity.
- 17 March 2017
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 25 (4) , 1125-1131
Reconstructing the anterolateral ligament does not decrease rotational knee laxity in ACL-reconstructed knees
Purpose Little is known about the anterolateral ligament’s (ALL) influence on knee laxity. The purpose of this study was to investigate rotational knee laxity against a pure axial rotational stress using radiostereometric analysis (RSA) after cutting and reconstructing both the anterior cruciate ligament (ACL) and the ALL. Methods Eight human donor legs were positioned and stereoradiographically recorded at 0°, 30° and 60° of knee flexion using a motorised fixture, while an internally rotating force of 4 Nm was applied to the foot. Anterior–posterior and rotational laxity were investigated for knees with intact ligaments and compared with those observed after successive ACL and ALL resection and reconstruction. Results After cutting the ALL in ACL-deficient knees, the internal rotation was increased in all three knee flexion angles, 0° (p = 0.04), 30° (p = 0.03) and 60° (p < 0.01) by 1.0°, 1.6° and 2.5°, respectively. However, no decrease in laxity was found after reconstructing the ALL in ACL-reconstructed knees. Conclusions The ALL was confirmed as a stabiliser of internal rotation in ACL-deficient knees. However, reconstructing the ALL using a gracilis autograft tendon did not decrease the internal rotation laxity in the ACL-reconstructed knee. Based on the results of this study, we do not recommend reconstructing the ALL in ACL-reconstructed knees to decrease internal knee laxity.