LLLan Li

Lan Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lan Li has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Rapid and High Sensitivity Temperature Measurement Based on Near-Extinction Photoelastic Modulated Magneto-Optical Kerr Effect of Fe-Gd Nanofilm

    by Lan Li, Wentong Yi, Xinchao Cui, Wenzhong Liu

    In this study, we demonstrate a novel magneto-optical thermometer using a Magneto-optical Kerr Effect (MOKE) system optimally configured with a photoelastic modulator (PEM) that combines the optical and pyro effects of Fe-Gd nanofilm to detect transient surface temperatures with high sensitivity and temporal resolution. The AC-DC harmonic ratio of the modulating frequency senses the temperature-induced Kerr signal of the metal film. In previous MOKE systems using a PEM, the optical axis of the analyzer was configured at 45° to maximize the harmonic amplitude. However, the decreased sensitivity of the harmonic ratio in this conventional configuration leads to lower signal-to-noise ratios (SNRs). By configuring the analyzer axis at a near-extinction position close to 0°, the signal gain of the harmonic ratio can be increased, thus significantly improving the SNRs of the temperature measurement. Experimental results based on near-extinction photoelastic modulated MOKE (NEPEM MOKE) of Fe-Gd nanofilm show that the harmonic ratio achieves a resolution better than 0.02 K over a wide range, from room temperature to the Curie temperature of Fe-Gd nanofilm. On this basis, the magneto-optical thermometer can capture thermal pulses with a pulse width of no less than 80 μs. The proposed method combines the high spatial and temporal resolution of the MOKE, which converts temperature changes into magneto-optical signal changes. Therefore, this noninvasive magneto-optical thermometer provides a possible method for temperature measurements on the micro- and nanometer scales.

  • A Rapid and Sensitive Magnetic Immunoassay of Biomolecules Based on Magnetic Nanoparticles

    by Xinchao Cui, Lan Li, Wenzhong Liu

    In this study, a real-time detection method for amol biomolecules based on 2nd and 3rd harmonics of water-based magnetic nanoparticles (MNPs) is reported. In previous magnetic immunoassay methods based on magnetic particle spectroscopy (MPS), the 1st harmonic was affected by the diamagnetic environment and would easily interfere with the signal at a concentration lower than pM MNPs. We propose to use the ratio of the 3rd to 2nd harmonics to achieve more sensitive immune detection by using an AC plus DC excitation magnetic field. We found that a homemade magnetic particle spectrometer can ensure that the signal-to-noise ratios of the 2nd and 3rd harmonics are roughly the same by modulating the DC magnetic field to compare and adjust the amplitudes of the 2nd and 3rd harmonics. The immunoassay sensitivity was greatly improved, and the ability of magnetic immunoassay based on water-based MNPs to detect trace biomolecules was roughly estimated using the limit of detection (LOD) for 0.4 pM (40 amol) biomolecules in a 100 μL suspension, by binding streptavidin to biotin. In addition, the entire test is completed within 1 s, which will be useful in testing for viral aerosols in the air.